Heat rate deviation analysis of a Coal-Fired Power Plant (CFPP) with the influence of Applicable Coal Prices (ACP)

The assessment of a Coal-Fired Power Plant (CFPP) performance is an intricate process that involves the determination of Heat Rate (HR) deviations of current operational parameters from baseline or target values. This study focuses on HR deviations of a CFPP based on the Applicable Coal Price (ACP),...

Full description

Saved in:
Bibliographic Details
Main Authors: Jasbeer Singh, Manmit Singh, Abdul Jalil, Nawal Aswan, Abdul Rahim, Sharafiz, Zulkefli, Zamir Aimaduddin, Hasini, Hasril
Format: Article
Published: Universiti Putra Malaysia Press 2023
Online Access:http://psasir.upm.edu.my/id/eprint/108157/
http://www.pertanika.upm.edu.my/pjst/browse/regular-issue?article=JST-3685-2022
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Universiti Putra Malaysia
id my.upm.eprints.108157
record_format eprints
spelling my.upm.eprints.1081572024-09-23T04:47:56Z http://psasir.upm.edu.my/id/eprint/108157/ Heat rate deviation analysis of a Coal-Fired Power Plant (CFPP) with the influence of Applicable Coal Prices (ACP) Jasbeer Singh, Manmit Singh Abdul Jalil, Nawal Aswan Abdul Rahim, Sharafiz Zulkefli, Zamir Aimaduddin Hasini, Hasril The assessment of a Coal-Fired Power Plant (CFPP) performance is an intricate process that involves the determination of Heat Rate (HR) deviations of current operational parameters from baseline or target values. This study focuses on HR deviations of a CFPP based on the Applicable Coal Price (ACP), and the influence of the ACP price on daily losses or gains are thoroughly analyzed for key performance parameters for three fixed ACP of RM12, 18, and 24 per GJ. This paper mainly investigates key parameters and related equipment that significantly affect the HR of the CFPP and ranks the parameters affecting HR from most significant to least significant. The baseline or target values are obtained from the plant commissioning manuals and the Performance Guarantee Test (PGT). Actual real-life operational data from a 700MWn CFPP is utilized to improve the accuracy and confidence levels of the results obtained. It was found that at the nominal operating baseload, the most significant negative HR deviation is for the Rotary Air Heater (RAH) gas exit temperature with a negative HR deviation of -137.9 kJ/kWh leading to an annual loss of RM17.6 million at ACP of RM24/GJ while the superheater and reheater spray flows are contributing least to the HR deviation. This analysis highlighting the impact of key parameters affecting the performance enables plant operations and maintenance teams to focus on such parameters to mitigate losses. Universiti Putra Malaysia Press 2023 Article PeerReviewed Jasbeer Singh, Manmit Singh and Abdul Jalil, Nawal Aswan and Abdul Rahim, Sharafiz and Zulkefli, Zamir Aimaduddin and Hasini, Hasril (2023) Heat rate deviation analysis of a Coal-Fired Power Plant (CFPP) with the influence of Applicable Coal Prices (ACP). Pertanika Journal of Science and Technology, 31 (3). pp. 1453-1474. ISSN 0128-7680; ESSN: 2231-8526 http://www.pertanika.upm.edu.my/pjst/browse/regular-issue?article=JST-3685-2022 10.47836/pjst.31.3.18
institution Universiti Putra Malaysia
building UPM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Putra Malaysia
content_source UPM Institutional Repository
url_provider http://psasir.upm.edu.my/
description The assessment of a Coal-Fired Power Plant (CFPP) performance is an intricate process that involves the determination of Heat Rate (HR) deviations of current operational parameters from baseline or target values. This study focuses on HR deviations of a CFPP based on the Applicable Coal Price (ACP), and the influence of the ACP price on daily losses or gains are thoroughly analyzed for key performance parameters for three fixed ACP of RM12, 18, and 24 per GJ. This paper mainly investigates key parameters and related equipment that significantly affect the HR of the CFPP and ranks the parameters affecting HR from most significant to least significant. The baseline or target values are obtained from the plant commissioning manuals and the Performance Guarantee Test (PGT). Actual real-life operational data from a 700MWn CFPP is utilized to improve the accuracy and confidence levels of the results obtained. It was found that at the nominal operating baseload, the most significant negative HR deviation is for the Rotary Air Heater (RAH) gas exit temperature with a negative HR deviation of -137.9 kJ/kWh leading to an annual loss of RM17.6 million at ACP of RM24/GJ while the superheater and reheater spray flows are contributing least to the HR deviation. This analysis highlighting the impact of key parameters affecting the performance enables plant operations and maintenance teams to focus on such parameters to mitigate losses.
format Article
author Jasbeer Singh, Manmit Singh
Abdul Jalil, Nawal Aswan
Abdul Rahim, Sharafiz
Zulkefli, Zamir Aimaduddin
Hasini, Hasril
spellingShingle Jasbeer Singh, Manmit Singh
Abdul Jalil, Nawal Aswan
Abdul Rahim, Sharafiz
Zulkefli, Zamir Aimaduddin
Hasini, Hasril
Heat rate deviation analysis of a Coal-Fired Power Plant (CFPP) with the influence of Applicable Coal Prices (ACP)
author_facet Jasbeer Singh, Manmit Singh
Abdul Jalil, Nawal Aswan
Abdul Rahim, Sharafiz
Zulkefli, Zamir Aimaduddin
Hasini, Hasril
author_sort Jasbeer Singh, Manmit Singh
title Heat rate deviation analysis of a Coal-Fired Power Plant (CFPP) with the influence of Applicable Coal Prices (ACP)
title_short Heat rate deviation analysis of a Coal-Fired Power Plant (CFPP) with the influence of Applicable Coal Prices (ACP)
title_full Heat rate deviation analysis of a Coal-Fired Power Plant (CFPP) with the influence of Applicable Coal Prices (ACP)
title_fullStr Heat rate deviation analysis of a Coal-Fired Power Plant (CFPP) with the influence of Applicable Coal Prices (ACP)
title_full_unstemmed Heat rate deviation analysis of a Coal-Fired Power Plant (CFPP) with the influence of Applicable Coal Prices (ACP)
title_sort heat rate deviation analysis of a coal-fired power plant (cfpp) with the influence of applicable coal prices (acp)
publisher Universiti Putra Malaysia Press
publishDate 2023
url http://psasir.upm.edu.my/id/eprint/108157/
http://www.pertanika.upm.edu.my/pjst/browse/regular-issue?article=JST-3685-2022
_version_ 1811686001425252352