Visualizing partially loosened fastener through frequency-wavenumber analysis of ultrasonic wavefield
Aerospace thin-walled structures and alike are susceptible to various damages and flaws, including the loosening of fasteners, that must be non-destructively evaluated and repaired to avoid catastrophic failure. Guided ultrasonic wavefield has great potential to evaluate loosened fasteners, but stat...
Saved in:
Main Authors: | , , , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
The Aeronautical and Astronautical Society of the Republic of China
2024
|
Online Access: | http://psasir.upm.edu.my/id/eprint/112202/1/112202.pdf http://psasir.upm.edu.my/id/eprint/112202/ https://www.airitilibrary.com/Article/Detail/P20140627004-N202403020027-00008 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Institution: | Universiti Putra Malaysia |
Language: | English |
id |
my.upm.eprints.112202 |
---|---|
record_format |
eprints |
spelling |
my.upm.eprints.1122022024-09-25T04:04:27Z http://psasir.upm.edu.my/id/eprint/112202/ Visualizing partially loosened fastener through frequency-wavenumber analysis of ultrasonic wavefield Lee, Shi Yn Chia, Chen Ciang Romli, Fairuz Izzuddin Mazlan, Norkhairunnisa Lee, Jung-Ryul Harmin, Mohammad Yazdi Aerospace thin-walled structures and alike are susceptible to various damages and flaws, including the loosening of fasteners, that must be non-destructively evaluated and repaired to avoid catastrophic failure. Guided ultrasonic wavefield has great potential to evaluate loosened fasteners, but state-of-the-art result processing methods are either not supporting direct visualisation of a loosened fastener or are unable to quantify the level of loosening. In this work, a more detailed analysis of the wavefield data was experimentally conducted in the frequency and wavenumber domains using wavenumber highpass and bandpass filters, as well as the wavenumber imaging algorithm. Six fasteners fixed at a simple aluminium plate were inspected, among which one was deliberately loosened from the nominal 100 lb-in to a few discrete levels to simulate a flaw. The imaging results revealed that a fastener loosened to 0, 20, 40, and 60 lb-in, respectively, could be distinctively visualised but marginally discernible when loosened to 80 lb-in. Further work is being conducted to improve the detection sensitivity and properly quantify the results. The Aeronautical and Astronautical Society of the Republic of China 2024-03 Article PeerReviewed text en http://psasir.upm.edu.my/id/eprint/112202/1/112202.pdf Lee, Shi Yn and Chia, Chen Ciang and Romli, Fairuz Izzuddin and Mazlan, Norkhairunnisa and Lee, Jung-Ryul and Harmin, Mohammad Yazdi (2024) Visualizing partially loosened fastener through frequency-wavenumber analysis of ultrasonic wavefield. Journal of Aeronautics, Astronautics and Aviation, 56 (1s). pp. 147-155. ISSN 1990-7710 https://www.airitilibrary.com/Article/Detail/P20140627004-N202403020027-00008 10.6125/JoAAA.202403_56(1S).07 |
institution |
Universiti Putra Malaysia |
building |
UPM Library |
collection |
Institutional Repository |
continent |
Asia |
country |
Malaysia |
content_provider |
Universiti Putra Malaysia |
content_source |
UPM Institutional Repository |
url_provider |
http://psasir.upm.edu.my/ |
language |
English |
description |
Aerospace thin-walled structures and alike are susceptible to various damages and flaws, including the loosening of fasteners, that must be non-destructively evaluated and repaired to avoid catastrophic failure. Guided ultrasonic wavefield has great potential to evaluate loosened fasteners, but state-of-the-art result processing methods are either not supporting direct visualisation of a loosened fastener or are unable to quantify the level of loosening. In this work, a more detailed analysis of the wavefield data was experimentally conducted in the frequency and wavenumber domains using wavenumber highpass and bandpass filters, as well as the wavenumber imaging algorithm. Six fasteners fixed at a simple aluminium plate were inspected, among which one was deliberately loosened from the nominal 100 lb-in to a few discrete levels to simulate a flaw. The imaging results revealed that a fastener loosened to 0, 20, 40, and 60 lb-in, respectively, could be distinctively visualised but marginally discernible when loosened to 80 lb-in. Further work is being conducted to improve the detection sensitivity and properly quantify the results. |
format |
Article |
author |
Lee, Shi Yn Chia, Chen Ciang Romli, Fairuz Izzuddin Mazlan, Norkhairunnisa Lee, Jung-Ryul Harmin, Mohammad Yazdi |
spellingShingle |
Lee, Shi Yn Chia, Chen Ciang Romli, Fairuz Izzuddin Mazlan, Norkhairunnisa Lee, Jung-Ryul Harmin, Mohammad Yazdi Visualizing partially loosened fastener through frequency-wavenumber analysis of ultrasonic wavefield |
author_facet |
Lee, Shi Yn Chia, Chen Ciang Romli, Fairuz Izzuddin Mazlan, Norkhairunnisa Lee, Jung-Ryul Harmin, Mohammad Yazdi |
author_sort |
Lee, Shi Yn |
title |
Visualizing partially loosened fastener through frequency-wavenumber analysis of ultrasonic wavefield |
title_short |
Visualizing partially loosened fastener through frequency-wavenumber analysis of ultrasonic wavefield |
title_full |
Visualizing partially loosened fastener through frequency-wavenumber analysis of ultrasonic wavefield |
title_fullStr |
Visualizing partially loosened fastener through frequency-wavenumber analysis of ultrasonic wavefield |
title_full_unstemmed |
Visualizing partially loosened fastener through frequency-wavenumber analysis of ultrasonic wavefield |
title_sort |
visualizing partially loosened fastener through frequency-wavenumber analysis of ultrasonic wavefield |
publisher |
The Aeronautical and Astronautical Society of the Republic of China |
publishDate |
2024 |
url |
http://psasir.upm.edu.my/id/eprint/112202/1/112202.pdf http://psasir.upm.edu.my/id/eprint/112202/ https://www.airitilibrary.com/Article/Detail/P20140627004-N202403020027-00008 |
_version_ |
1811686084931747840 |