Fabrication of a highly selective and sensitive CrO4 sensor based on a N,N'Bis(salicylidene)ethylenediaminocobolt(II)hydrate.

In this work a membrane was prepared by use of N,N′Bis(salicylidene) ethylenediamino cobalt(II) hydrate (Co(SALEN)2) as an ion carrier, polyvinylchloride (PVC) as matrix, and 2-nitrophenyl octyl ether (2NPOE) as a plasticizer for an ion-selective electrode used in the measurement of CrO42-anions in...

Full description

Saved in:
Bibliographic Details
Main Authors: Kassim, Anuar, Rezayi, Majid, Ahmad Zadeh, Saeed, Tan, Wee Tee, Yusof, Nor Azah, Lee, Yook Heng
Format: Article
Language:English
English
Published: Institut Kimia Malaysia 2009
Online Access:http://psasir.upm.edu.my/id/eprint/14687/1/Fabrication%20of%20a%20highly%20selective%20and%20sensitive%20CrO4%20sensor%20based%20on%20a%20N.pdf
http://psasir.upm.edu.my/id/eprint/14687/
http://www.ikm.org.my/index.php?option=com_content&view=article&id=97&Itemid=92
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Universiti Putra Malaysia
Language: English
English
id my.upm.eprints.14687
record_format eprints
spelling my.upm.eprints.146872015-09-28T01:42:19Z http://psasir.upm.edu.my/id/eprint/14687/ Fabrication of a highly selective and sensitive CrO4 sensor based on a N,N'Bis(salicylidene)ethylenediaminocobolt(II)hydrate. Kassim, Anuar Rezayi, Majid Ahmad Zadeh, Saeed Tan, Wee Tee Yusof, Nor Azah Lee, Yook Heng In this work a membrane was prepared by use of N,N′Bis(salicylidene) ethylenediamino cobalt(II) hydrate (Co(SALEN)2) as an ion carrier, polyvinylchloride (PVC) as matrix, and 2-nitrophenyl octyl ether (2NPOE) as a plasticizer for an ion-selective electrode used in the measurement of CrO42-anions in solution. The amounts of (Co(SALEN)2) and PVC were optimized in the preparation of the membrane. The response of the electrode was Nernstian within the concentration range 1.0 × 10-6 to 1.0 × 10-1 M. This sensor displays a drift in Nernstian response for this anion changes with the amount of ionophore and PVC. The effects of various parameters such as pH, different anion interferences, the amounts of ionophore and PVC and time on response of the coated ion-selective electrode were investigated. The response of the fabricated electrode at concentration range from 1.0× 10-6 to 1.0× 10-1 M is linear with a Nernstian slope of -28.33 mV. Institut Kimia Malaysia 2009 Article PeerReviewed application/pdf en http://psasir.upm.edu.my/id/eprint/14687/1/Fabrication%20of%20a%20highly%20selective%20and%20sensitive%20CrO4%20sensor%20based%20on%20a%20N.pdf Kassim, Anuar and Rezayi, Majid and Ahmad Zadeh, Saeed and Tan, Wee Tee and Yusof, Nor Azah and Lee, Yook Heng (2009) Fabrication of a highly selective and sensitive CrO4 sensor based on a N,N'Bis(salicylidene)ethylenediaminocobolt(II)hydrate. Malaysian Journal of Chemistry, 11 (1). pp. 19-25. ISSN 1511-2292 http://www.ikm.org.my/index.php?option=com_content&view=article&id=97&Itemid=92 English
institution Universiti Putra Malaysia
building UPM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Putra Malaysia
content_source UPM Institutional Repository
url_provider http://psasir.upm.edu.my/
language English
English
description In this work a membrane was prepared by use of N,N′Bis(salicylidene) ethylenediamino cobalt(II) hydrate (Co(SALEN)2) as an ion carrier, polyvinylchloride (PVC) as matrix, and 2-nitrophenyl octyl ether (2NPOE) as a plasticizer for an ion-selective electrode used in the measurement of CrO42-anions in solution. The amounts of (Co(SALEN)2) and PVC were optimized in the preparation of the membrane. The response of the electrode was Nernstian within the concentration range 1.0 × 10-6 to 1.0 × 10-1 M. This sensor displays a drift in Nernstian response for this anion changes with the amount of ionophore and PVC. The effects of various parameters such as pH, different anion interferences, the amounts of ionophore and PVC and time on response of the coated ion-selective electrode were investigated. The response of the fabricated electrode at concentration range from 1.0× 10-6 to 1.0× 10-1 M is linear with a Nernstian slope of -28.33 mV.
format Article
author Kassim, Anuar
Rezayi, Majid
Ahmad Zadeh, Saeed
Tan, Wee Tee
Yusof, Nor Azah
Lee, Yook Heng
spellingShingle Kassim, Anuar
Rezayi, Majid
Ahmad Zadeh, Saeed
Tan, Wee Tee
Yusof, Nor Azah
Lee, Yook Heng
Fabrication of a highly selective and sensitive CrO4 sensor based on a N,N'Bis(salicylidene)ethylenediaminocobolt(II)hydrate.
author_facet Kassim, Anuar
Rezayi, Majid
Ahmad Zadeh, Saeed
Tan, Wee Tee
Yusof, Nor Azah
Lee, Yook Heng
author_sort Kassim, Anuar
title Fabrication of a highly selective and sensitive CrO4 sensor based on a N,N'Bis(salicylidene)ethylenediaminocobolt(II)hydrate.
title_short Fabrication of a highly selective and sensitive CrO4 sensor based on a N,N'Bis(salicylidene)ethylenediaminocobolt(II)hydrate.
title_full Fabrication of a highly selective and sensitive CrO4 sensor based on a N,N'Bis(salicylidene)ethylenediaminocobolt(II)hydrate.
title_fullStr Fabrication of a highly selective and sensitive CrO4 sensor based on a N,N'Bis(salicylidene)ethylenediaminocobolt(II)hydrate.
title_full_unstemmed Fabrication of a highly selective and sensitive CrO4 sensor based on a N,N'Bis(salicylidene)ethylenediaminocobolt(II)hydrate.
title_sort fabrication of a highly selective and sensitive cro4 sensor based on a n,n'bis(salicylidene)ethylenediaminocobolt(ii)hydrate.
publisher Institut Kimia Malaysia
publishDate 2009
url http://psasir.upm.edu.my/id/eprint/14687/1/Fabrication%20of%20a%20highly%20selective%20and%20sensitive%20CrO4%20sensor%20based%20on%20a%20N.pdf
http://psasir.upm.edu.my/id/eprint/14687/
http://www.ikm.org.my/index.php?option=com_content&view=article&id=97&Itemid=92
_version_ 1643825708247547904