Fabrication of a highly selective and sensitive CrO4 sensor based on a N,N'Bis(salicylidene)ethylenediaminocobolt(II)hydrate.
In this work a membrane was prepared by use of N,N′Bis(salicylidene) ethylenediamino cobalt(II) hydrate (Co(SALEN)2) as an ion carrier, polyvinylchloride (PVC) as matrix, and 2-nitrophenyl octyl ether (2NPOE) as a plasticizer for an ion-selective electrode used in the measurement of CrO42-anions in...
Saved in:
Main Authors: | , , , , , |
---|---|
Format: | Article |
Language: | English English |
Published: |
Institut Kimia Malaysia
2009
|
Online Access: | http://psasir.upm.edu.my/id/eprint/14687/1/Fabrication%20of%20a%20highly%20selective%20and%20sensitive%20CrO4%20sensor%20based%20on%20a%20N.pdf http://psasir.upm.edu.my/id/eprint/14687/ http://www.ikm.org.my/index.php?option=com_content&view=article&id=97&Itemid=92 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Institution: | Universiti Putra Malaysia |
Language: | English English |
id |
my.upm.eprints.14687 |
---|---|
record_format |
eprints |
spelling |
my.upm.eprints.146872015-09-28T01:42:19Z http://psasir.upm.edu.my/id/eprint/14687/ Fabrication of a highly selective and sensitive CrO4 sensor based on a N,N'Bis(salicylidene)ethylenediaminocobolt(II)hydrate. Kassim, Anuar Rezayi, Majid Ahmad Zadeh, Saeed Tan, Wee Tee Yusof, Nor Azah Lee, Yook Heng In this work a membrane was prepared by use of N,N′Bis(salicylidene) ethylenediamino cobalt(II) hydrate (Co(SALEN)2) as an ion carrier, polyvinylchloride (PVC) as matrix, and 2-nitrophenyl octyl ether (2NPOE) as a plasticizer for an ion-selective electrode used in the measurement of CrO42-anions in solution. The amounts of (Co(SALEN)2) and PVC were optimized in the preparation of the membrane. The response of the electrode was Nernstian within the concentration range 1.0 × 10-6 to 1.0 × 10-1 M. This sensor displays a drift in Nernstian response for this anion changes with the amount of ionophore and PVC. The effects of various parameters such as pH, different anion interferences, the amounts of ionophore and PVC and time on response of the coated ion-selective electrode were investigated. The response of the fabricated electrode at concentration range from 1.0× 10-6 to 1.0× 10-1 M is linear with a Nernstian slope of -28.33 mV. Institut Kimia Malaysia 2009 Article PeerReviewed application/pdf en http://psasir.upm.edu.my/id/eprint/14687/1/Fabrication%20of%20a%20highly%20selective%20and%20sensitive%20CrO4%20sensor%20based%20on%20a%20N.pdf Kassim, Anuar and Rezayi, Majid and Ahmad Zadeh, Saeed and Tan, Wee Tee and Yusof, Nor Azah and Lee, Yook Heng (2009) Fabrication of a highly selective and sensitive CrO4 sensor based on a N,N'Bis(salicylidene)ethylenediaminocobolt(II)hydrate. Malaysian Journal of Chemistry, 11 (1). pp. 19-25. ISSN 1511-2292 http://www.ikm.org.my/index.php?option=com_content&view=article&id=97&Itemid=92 English |
institution |
Universiti Putra Malaysia |
building |
UPM Library |
collection |
Institutional Repository |
continent |
Asia |
country |
Malaysia |
content_provider |
Universiti Putra Malaysia |
content_source |
UPM Institutional Repository |
url_provider |
http://psasir.upm.edu.my/ |
language |
English English |
description |
In this work a membrane was prepared by use of N,N′Bis(salicylidene) ethylenediamino cobalt(II) hydrate (Co(SALEN)2) as an ion carrier, polyvinylchloride (PVC) as matrix, and 2-nitrophenyl octyl ether (2NPOE) as a plasticizer for an ion-selective electrode used in the measurement of CrO42-anions in solution. The amounts of (Co(SALEN)2) and PVC were optimized in the preparation of the membrane. The response of the electrode was Nernstian within the concentration range 1.0 × 10-6 to 1.0 × 10-1 M. This sensor displays a drift in Nernstian response for this anion changes with the amount of ionophore and PVC. The effects of various parameters such as pH, different anion interferences, the amounts of ionophore and PVC and time on response of the coated ion-selective electrode were investigated. The response of the fabricated electrode at concentration range from 1.0× 10-6 to 1.0× 10-1 M is linear with a Nernstian slope of -28.33 mV. |
format |
Article |
author |
Kassim, Anuar Rezayi, Majid Ahmad Zadeh, Saeed Tan, Wee Tee Yusof, Nor Azah Lee, Yook Heng |
spellingShingle |
Kassim, Anuar Rezayi, Majid Ahmad Zadeh, Saeed Tan, Wee Tee Yusof, Nor Azah Lee, Yook Heng Fabrication of a highly selective and sensitive CrO4 sensor based on a N,N'Bis(salicylidene)ethylenediaminocobolt(II)hydrate. |
author_facet |
Kassim, Anuar Rezayi, Majid Ahmad Zadeh, Saeed Tan, Wee Tee Yusof, Nor Azah Lee, Yook Heng |
author_sort |
Kassim, Anuar |
title |
Fabrication of a highly selective and sensitive CrO4 sensor based on a N,N'Bis(salicylidene)ethylenediaminocobolt(II)hydrate. |
title_short |
Fabrication of a highly selective and sensitive CrO4 sensor based on a N,N'Bis(salicylidene)ethylenediaminocobolt(II)hydrate. |
title_full |
Fabrication of a highly selective and sensitive CrO4 sensor based on a N,N'Bis(salicylidene)ethylenediaminocobolt(II)hydrate. |
title_fullStr |
Fabrication of a highly selective and sensitive CrO4 sensor based on a N,N'Bis(salicylidene)ethylenediaminocobolt(II)hydrate. |
title_full_unstemmed |
Fabrication of a highly selective and sensitive CrO4 sensor based on a N,N'Bis(salicylidene)ethylenediaminocobolt(II)hydrate. |
title_sort |
fabrication of a highly selective and sensitive cro4 sensor based on a n,n'bis(salicylidene)ethylenediaminocobolt(ii)hydrate. |
publisher |
Institut Kimia Malaysia |
publishDate |
2009 |
url |
http://psasir.upm.edu.my/id/eprint/14687/1/Fabrication%20of%20a%20highly%20selective%20and%20sensitive%20CrO4%20sensor%20based%20on%20a%20N.pdf http://psasir.upm.edu.my/id/eprint/14687/ http://www.ikm.org.my/index.php?option=com_content&view=article&id=97&Itemid=92 |
_version_ |
1643825708247547904 |