Investigation of the effect of winding clamping structure on frequency response signature of 11 kV distribution transformer
This paper presents an investigation on the sensitivity of frequency response of a 500 kVA, 11/0.433 kV distribution transformer with and without the presence of a winding clamping structure. Frequency response analysis (FRA) measurements of multiple test configurations were carried out with and wit...
Saved in:
Main Authors: | , , , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
MDPI
2018
|
Online Access: | http://psasir.upm.edu.my/id/eprint/15365/1/15365.pdf http://psasir.upm.edu.my/id/eprint/15365/ https://www.mdpi.com/1996-1073/11/9/2307 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Institution: | Universiti Putra Malaysia |
Language: | English |
id |
my.upm.eprints.15365 |
---|---|
record_format |
eprints |
spelling |
my.upm.eprints.153652019-07-08T07:30:42Z http://psasir.upm.edu.my/id/eprint/15365/ Investigation of the effect of winding clamping structure on frequency response signature of 11 kV distribution transformer Murthy, Avinash Srikanta Azis, Norhafiz Al-Ameri, Salem Mohd Yousof, Mohd Fairouz Jasni, Jasronita Talib, Mohd Aizam This paper presents an investigation on the sensitivity of frequency response of a 500 kVA, 11/0.433 kV distribution transformer with and without the presence of a winding clamping structure. Frequency response analysis (FRA) measurements of multiple test configurations were carried out with and without the presence of a winding clamping structure. Statistical analyses based on Pearson’s correlation coefficient (PCC), Spearman’s correlation coefficient (SCC), Kendall’s correlation coefficient (KCC), cross-correlation coefficient (CCF), root mean square error (RMSE), absolute sum of logarithmic error (ASLE), hypothesis test (F-test) and relative factor (RF) were applied to determine the effect of the winding clamping structure. It was found that the removal of the winding clamping structure has an impact on the frequency response signature at the frequency less than 2 kHz during offline measurement. It was found that ASLE and F-test are suitable methods that can be used to indicate the variation of frequency response caused by clamping structure removal of the distribution transformer under study. MDPI 2018 Article PeerReviewed text en http://psasir.upm.edu.my/id/eprint/15365/1/15365.pdf Murthy, Avinash Srikanta and Azis, Norhafiz and Al-Ameri, Salem and Mohd Yousof, Mohd Fairouz and Jasni, Jasronita and Talib, Mohd Aizam (2018) Investigation of the effect of winding clamping structure on frequency response signature of 11 kV distribution transformer. Energies, 11 (9). art. no. 2307. pp. 1-13. ISSN 1996-1073 https://www.mdpi.com/1996-1073/11/9/2307 10.3390/en11092307 |
institution |
Universiti Putra Malaysia |
building |
UPM Library |
collection |
Institutional Repository |
continent |
Asia |
country |
Malaysia |
content_provider |
Universiti Putra Malaysia |
content_source |
UPM Institutional Repository |
url_provider |
http://psasir.upm.edu.my/ |
language |
English |
description |
This paper presents an investigation on the sensitivity of frequency response of a 500 kVA, 11/0.433 kV distribution transformer with and without the presence of a winding clamping structure. Frequency response analysis (FRA) measurements of multiple test configurations were carried out with and without the presence of a winding clamping structure. Statistical analyses based on Pearson’s correlation coefficient (PCC), Spearman’s correlation coefficient (SCC), Kendall’s correlation coefficient (KCC), cross-correlation coefficient (CCF), root mean square error (RMSE), absolute sum of logarithmic error (ASLE), hypothesis test (F-test) and relative factor (RF) were applied to determine the effect of the winding clamping structure. It was found that the removal of the winding clamping structure has an impact on the frequency response signature at the frequency less than 2 kHz during offline measurement. It was found that ASLE and F-test are suitable methods that can be used to indicate the variation of frequency response caused by clamping structure removal of the distribution transformer under study. |
format |
Article |
author |
Murthy, Avinash Srikanta Azis, Norhafiz Al-Ameri, Salem Mohd Yousof, Mohd Fairouz Jasni, Jasronita Talib, Mohd Aizam |
spellingShingle |
Murthy, Avinash Srikanta Azis, Norhafiz Al-Ameri, Salem Mohd Yousof, Mohd Fairouz Jasni, Jasronita Talib, Mohd Aizam Investigation of the effect of winding clamping structure on frequency response signature of 11 kV distribution transformer |
author_facet |
Murthy, Avinash Srikanta Azis, Norhafiz Al-Ameri, Salem Mohd Yousof, Mohd Fairouz Jasni, Jasronita Talib, Mohd Aizam |
author_sort |
Murthy, Avinash Srikanta |
title |
Investigation of the effect of winding clamping structure on frequency response signature of 11 kV distribution transformer |
title_short |
Investigation of the effect of winding clamping structure on frequency response signature of 11 kV distribution transformer |
title_full |
Investigation of the effect of winding clamping structure on frequency response signature of 11 kV distribution transformer |
title_fullStr |
Investigation of the effect of winding clamping structure on frequency response signature of 11 kV distribution transformer |
title_full_unstemmed |
Investigation of the effect of winding clamping structure on frequency response signature of 11 kV distribution transformer |
title_sort |
investigation of the effect of winding clamping structure on frequency response signature of 11 kv distribution transformer |
publisher |
MDPI |
publishDate |
2018 |
url |
http://psasir.upm.edu.my/id/eprint/15365/1/15365.pdf http://psasir.upm.edu.my/id/eprint/15365/ https://www.mdpi.com/1996-1073/11/9/2307 |
_version_ |
1643825912928534528 |