Non-invertable online signature biometric template protection via shuffling and trigonometry transformation

This paper describes a novel approach to a cancelable template protection scheme that secures online handwritten signature samples in the reference database of a biometric verification system. We propose a renewable-noninvertible transformation process named Bio-Trigono comprising two consecutive st...

Full description

Saved in:
Bibliographic Details
Main Authors: Malallah, Fahad Layth, Syed Ahmad Abdul Rahman, Sharifah Mumtazah, Wan Adnan, Wan Azizun, Yusoff, Salman
Format: Article
Published: Foundation of Computer Science 2014
Online Access:http://psasir.upm.edu.my/id/eprint/34662/
http://www.ijcaonline.org/archives/volume98/number4/17169-7240
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Universiti Putra Malaysia
id my.upm.eprints.34662
record_format eprints
spelling my.upm.eprints.346622015-12-18T00:06:02Z http://psasir.upm.edu.my/id/eprint/34662/ Non-invertable online signature biometric template protection via shuffling and trigonometry transformation Malallah, Fahad Layth Syed Ahmad Abdul Rahman, Sharifah Mumtazah Wan Adnan, Wan Azizun Yusoff, Salman This paper describes a novel approach to a cancelable template protection scheme that secures online handwritten signature samples in the reference database of a biometric verification system. We propose a renewable-noninvertible transformation process named Bio-Trigono comprising two consecutive steps. First, a shuffling scheme is applied to a signature sample to attain the renewability property for template protection. This is followed by the deployment of a cosine function for which its periodic characteristic is exploited to achieve a much desired non-invertible property for additional security. The overall template protection scheme was tested rigorously on signature samples of a SIGMA database through an online signature verification system. Its verification utilized the Principal Component Analysis (PCA) for features' extraction and the Artificial Neural Network (ANN) for user reference modeling and classification processes. Results demonstrated an effective cancelable template protection scheme whereby the best averaged error rates were 10. 3, 10. 5 and 14. 1% for un-transformed first and second transformed signature templates, respectively. Foundation of Computer Science 2014-07 Article PeerReviewed Malallah, Fahad Layth and Syed Ahmad Abdul Rahman, Sharifah Mumtazah and Wan Adnan, Wan Azizun and Yusoff, Salman (2014) Non-invertable online signature biometric template protection via shuffling and trigonometry transformation. International Journal of Computer Applications, 98 (4). pp. 4-17. ISSN 0975-8887 http://www.ijcaonline.org/archives/volume98/number4/17169-7240
institution Universiti Putra Malaysia
building UPM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Putra Malaysia
content_source UPM Institutional Repository
url_provider http://psasir.upm.edu.my/
description This paper describes a novel approach to a cancelable template protection scheme that secures online handwritten signature samples in the reference database of a biometric verification system. We propose a renewable-noninvertible transformation process named Bio-Trigono comprising two consecutive steps. First, a shuffling scheme is applied to a signature sample to attain the renewability property for template protection. This is followed by the deployment of a cosine function for which its periodic characteristic is exploited to achieve a much desired non-invertible property for additional security. The overall template protection scheme was tested rigorously on signature samples of a SIGMA database through an online signature verification system. Its verification utilized the Principal Component Analysis (PCA) for features' extraction and the Artificial Neural Network (ANN) for user reference modeling and classification processes. Results demonstrated an effective cancelable template protection scheme whereby the best averaged error rates were 10. 3, 10. 5 and 14. 1% for un-transformed first and second transformed signature templates, respectively.
format Article
author Malallah, Fahad Layth
Syed Ahmad Abdul Rahman, Sharifah Mumtazah
Wan Adnan, Wan Azizun
Yusoff, Salman
spellingShingle Malallah, Fahad Layth
Syed Ahmad Abdul Rahman, Sharifah Mumtazah
Wan Adnan, Wan Azizun
Yusoff, Salman
Non-invertable online signature biometric template protection via shuffling and trigonometry transformation
author_facet Malallah, Fahad Layth
Syed Ahmad Abdul Rahman, Sharifah Mumtazah
Wan Adnan, Wan Azizun
Yusoff, Salman
author_sort Malallah, Fahad Layth
title Non-invertable online signature biometric template protection via shuffling and trigonometry transformation
title_short Non-invertable online signature biometric template protection via shuffling and trigonometry transformation
title_full Non-invertable online signature biometric template protection via shuffling and trigonometry transformation
title_fullStr Non-invertable online signature biometric template protection via shuffling and trigonometry transformation
title_full_unstemmed Non-invertable online signature biometric template protection via shuffling and trigonometry transformation
title_sort non-invertable online signature biometric template protection via shuffling and trigonometry transformation
publisher Foundation of Computer Science
publishDate 2014
url http://psasir.upm.edu.my/id/eprint/34662/
http://www.ijcaonline.org/archives/volume98/number4/17169-7240
_version_ 1643831221146353664