In vitro evaluation of finger's hemodynamics for vein graft surveillance using electrical bio-impedance method
Electrical bio-impedance measurement has great potential in many biomedical applications including vein graft surveillance. Studies have shown that thrombosis was the major cause of the vein graft failure. The meticulous skills of the surgeon and effective postoperative surveillance of vein graft re...
Saved in:
Main Authors: | , , , , , , , , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
American-Eurasian Network for Scientific Information
2014
|
Online Access: | http://psasir.upm.edu.my/id/eprint/38008/1/In%20vitro%20evaluation%20of%20finger%27s%20hemodynamics%20for%20vein%20graft%20surveillance%20using%20electrical%20bio-impedance%20method.pdf http://psasir.upm.edu.my/id/eprint/38008/ http://ajbasweb.com/old/2-ajbas_Special_2014.html |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Institution: | Universiti Putra Malaysia |
Language: | English |
id |
my.upm.eprints.38008 |
---|---|
record_format |
eprints |
spelling |
my.upm.eprints.380082019-06-28T00:51:10Z http://psasir.upm.edu.my/id/eprint/38008/ In vitro evaluation of finger's hemodynamics for vein graft surveillance using electrical bio-impedance method Lee, Hoi Leong Abu Bakar, Shahriman Yaacob, Sazali Mohamad Razlan, Zuradzman Wan Ahmad, Wan Khairunizam Ibrahim, Zunaidi Cheng, Ee Meng Zaaba, Siti Khadijah Basah, Shafriza Nisha Rojan, Mohd Afendi Syed Waseem Ahmad, Sharifah Roohi Electrical bio-impedance measurement has great potential in many biomedical applications including vein graft surveillance. Studies have shown that thrombosis was the major cause of the vein graft failure. The meticulous skills of the surgeon and effective postoperative surveillance of vein graft remain the cornerstones of clinical success in the current surgical management of vein graft survival. Vascular blood flow is the key clinical indicators for the evaluation of patency of the vein graft and ensuring the patient's quality of life. In this work, electrical bio-impedance method has been proposed as an alternative to the existing surveillance method as it is non-invasive, portable, easy applicable in practice, fast response, radiation free, and required only low-cost instrumentation. It was employed to measure pulsatile changes in longitudinal bio-impedance to quantify arterial blood flow and blood volume. We expect that by measuring the changes in tissue bio-impedance which can be used to evaluate important peripheral hemodynamic, it allows the detection of early stage stenosis within vascular and vein graft as well as estimate its severity with predetermined normative data provided. American-Eurasian Network for Scientific Information 2014 Article PeerReviewed application/pdf en http://psasir.upm.edu.my/id/eprint/38008/1/In%20vitro%20evaluation%20of%20finger%27s%20hemodynamics%20for%20vein%20graft%20surveillance%20using%20electrical%20bio-impedance%20method.pdf Lee, Hoi Leong and Abu Bakar, Shahriman and Yaacob, Sazali and Mohamad Razlan, Zuradzman and Wan Ahmad, Wan Khairunizam and Ibrahim, Zunaidi and Cheng, Ee Meng and Zaaba, Siti Khadijah and Basah, Shafriza Nisha and Rojan, Mohd Afendi and Syed Waseem Ahmad, Sharifah Roohi (2014) In vitro evaluation of finger's hemodynamics for vein graft surveillance using electrical bio-impedance method. Australian Journal of Basic and Applied Sciences, 8 (spec.4). pp. 350-359. ISSN 1991-8178 http://ajbasweb.com/old/2-ajbas_Special_2014.html |
institution |
Universiti Putra Malaysia |
building |
UPM Library |
collection |
Institutional Repository |
continent |
Asia |
country |
Malaysia |
content_provider |
Universiti Putra Malaysia |
content_source |
UPM Institutional Repository |
url_provider |
http://psasir.upm.edu.my/ |
language |
English |
description |
Electrical bio-impedance measurement has great potential in many biomedical applications including vein graft surveillance. Studies have shown that thrombosis was the major cause of the vein graft failure. The meticulous skills of the surgeon and effective postoperative surveillance of vein graft remain the cornerstones of clinical success in the current surgical management of vein graft survival. Vascular blood flow is the key clinical indicators for the evaluation of patency of the vein graft and ensuring the patient's quality of life. In this work, electrical bio-impedance method has been proposed as an alternative to the existing surveillance method as it is non-invasive, portable, easy applicable in practice, fast response, radiation free, and required only low-cost instrumentation. It was employed to measure pulsatile changes in longitudinal bio-impedance to quantify arterial blood flow and blood volume. We expect that by measuring the changes in tissue bio-impedance which can be used to evaluate important peripheral hemodynamic, it allows the detection of early stage stenosis within vascular and vein graft as well as estimate its severity with predetermined normative data provided. |
format |
Article |
author |
Lee, Hoi Leong Abu Bakar, Shahriman Yaacob, Sazali Mohamad Razlan, Zuradzman Wan Ahmad, Wan Khairunizam Ibrahim, Zunaidi Cheng, Ee Meng Zaaba, Siti Khadijah Basah, Shafriza Nisha Rojan, Mohd Afendi Syed Waseem Ahmad, Sharifah Roohi |
spellingShingle |
Lee, Hoi Leong Abu Bakar, Shahriman Yaacob, Sazali Mohamad Razlan, Zuradzman Wan Ahmad, Wan Khairunizam Ibrahim, Zunaidi Cheng, Ee Meng Zaaba, Siti Khadijah Basah, Shafriza Nisha Rojan, Mohd Afendi Syed Waseem Ahmad, Sharifah Roohi In vitro evaluation of finger's hemodynamics for vein graft surveillance using electrical bio-impedance method |
author_facet |
Lee, Hoi Leong Abu Bakar, Shahriman Yaacob, Sazali Mohamad Razlan, Zuradzman Wan Ahmad, Wan Khairunizam Ibrahim, Zunaidi Cheng, Ee Meng Zaaba, Siti Khadijah Basah, Shafriza Nisha Rojan, Mohd Afendi Syed Waseem Ahmad, Sharifah Roohi |
author_sort |
Lee, Hoi Leong |
title |
In vitro evaluation of finger's hemodynamics for vein graft surveillance using electrical bio-impedance method |
title_short |
In vitro evaluation of finger's hemodynamics for vein graft surveillance using electrical bio-impedance method |
title_full |
In vitro evaluation of finger's hemodynamics for vein graft surveillance using electrical bio-impedance method |
title_fullStr |
In vitro evaluation of finger's hemodynamics for vein graft surveillance using electrical bio-impedance method |
title_full_unstemmed |
In vitro evaluation of finger's hemodynamics for vein graft surveillance using electrical bio-impedance method |
title_sort |
in vitro evaluation of finger's hemodynamics for vein graft surveillance using electrical bio-impedance method |
publisher |
American-Eurasian Network for Scientific Information |
publishDate |
2014 |
url |
http://psasir.upm.edu.my/id/eprint/38008/1/In%20vitro%20evaluation%20of%20finger%27s%20hemodynamics%20for%20vein%20graft%20surveillance%20using%20electrical%20bio-impedance%20method.pdf http://psasir.upm.edu.my/id/eprint/38008/ http://ajbasweb.com/old/2-ajbas_Special_2014.html |
_version_ |
1643832123479556096 |