Variation of coefficient of friction and friction head losses along a pipe with multiple outlets

The flow in a pipe having multiple outlets is considered as an advanced problem in hydraulic engineering; many discrepancies were found in the literature, in addition to the lack of experimental and field studies. The main goal of this study is to simulate the flow in a pipe with multiple outlets in...

Full description

Saved in:
Bibliographic Details
Main Authors: Alawee, Wissam H., Almolhem, Yousef A., Yusuf, Badronnisa, Mohammad, Thamer Ahmad, Dhahad, Hayder A.
Format: Article
Language:English
Published: MDPI 2020
Online Access:http://psasir.upm.edu.my/id/eprint/38120/1/38120.pdf
http://psasir.upm.edu.my/id/eprint/38120/
https://www.mdpi.com/2073-4441/12/3/844
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Universiti Putra Malaysia
Language: English
id my.upm.eprints.38120
record_format eprints
spelling my.upm.eprints.381202020-04-14T13:53:54Z http://psasir.upm.edu.my/id/eprint/38120/ Variation of coefficient of friction and friction head losses along a pipe with multiple outlets Alawee, Wissam H. Almolhem, Yousef A. Yusuf, Badronnisa Mohammad, Thamer Ahmad Dhahad, Hayder A. The flow in a pipe having multiple outlets is considered as an advanced problem in hydraulic engineering; many discrepancies were found in the literature, in addition to the lack of experimental and field studies. The main goal of this study is to simulate the flow in a pipe with multiple outlets in order to examine the existing methodologies for estimation of the friction head losses, and to propose a methodology that is based on experimental data. The main physical model in this study consisted of a water supply tank, a pipe with multiple outlets having a piezometer at each outlet. Different pipe diameters were used in this study, the pipe diameters were 25.4 mm (1 in), 38.1 mm (1.5 in), 50.8 (2 in) and 76.2 mm (3 in). The inlet heads used were 1.7 m and 2.2 m. The data collected from different flow conditions were used to assess the variation in the coefficient of friction and friction head losses along the pipe length. It can be concluded that the spacing between any two successive outlets (S) and area ratio (AR = Area of outlet/Area of the main pipe) are the main factors affecting the friction head losses along the pipe. The ratio of total friction head losses along a pipe with outlets having the same properties (length (L), discharge (Q), diameter (d) and material) to a pipe without outlets and having the same properties is called the G factor. The G factor calculated using selected formulae was overestimated in comparison to the calculated G factor obtained from experimental data. For large values of S/d (spacing between outlets/diameter of main pipe), the difference between coefficient of friction in first segment (f1) and last segment (fn) of the multiple outlet pipe was noted to be minimal. MDPI 2020 Article PeerReviewed text en http://psasir.upm.edu.my/id/eprint/38120/1/38120.pdf Alawee, Wissam H. and Almolhem, Yousef A. and Yusuf, Badronnisa and Mohammad, Thamer Ahmad and Dhahad, Hayder A. (2020) Variation of coefficient of friction and friction head losses along a pipe with multiple outlets. Water, 12 (3). art. no. 844. pp. 1-15. ISSN 2073-4441 https://www.mdpi.com/2073-4441/12/3/844 10.3390/w12030844
institution Universiti Putra Malaysia
building UPM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Putra Malaysia
content_source UPM Institutional Repository
url_provider http://psasir.upm.edu.my/
language English
description The flow in a pipe having multiple outlets is considered as an advanced problem in hydraulic engineering; many discrepancies were found in the literature, in addition to the lack of experimental and field studies. The main goal of this study is to simulate the flow in a pipe with multiple outlets in order to examine the existing methodologies for estimation of the friction head losses, and to propose a methodology that is based on experimental data. The main physical model in this study consisted of a water supply tank, a pipe with multiple outlets having a piezometer at each outlet. Different pipe diameters were used in this study, the pipe diameters were 25.4 mm (1 in), 38.1 mm (1.5 in), 50.8 (2 in) and 76.2 mm (3 in). The inlet heads used were 1.7 m and 2.2 m. The data collected from different flow conditions were used to assess the variation in the coefficient of friction and friction head losses along the pipe length. It can be concluded that the spacing between any two successive outlets (S) and area ratio (AR = Area of outlet/Area of the main pipe) are the main factors affecting the friction head losses along the pipe. The ratio of total friction head losses along a pipe with outlets having the same properties (length (L), discharge (Q), diameter (d) and material) to a pipe without outlets and having the same properties is called the G factor. The G factor calculated using selected formulae was overestimated in comparison to the calculated G factor obtained from experimental data. For large values of S/d (spacing between outlets/diameter of main pipe), the difference between coefficient of friction in first segment (f1) and last segment (fn) of the multiple outlet pipe was noted to be minimal.
format Article
author Alawee, Wissam H.
Almolhem, Yousef A.
Yusuf, Badronnisa
Mohammad, Thamer Ahmad
Dhahad, Hayder A.
spellingShingle Alawee, Wissam H.
Almolhem, Yousef A.
Yusuf, Badronnisa
Mohammad, Thamer Ahmad
Dhahad, Hayder A.
Variation of coefficient of friction and friction head losses along a pipe with multiple outlets
author_facet Alawee, Wissam H.
Almolhem, Yousef A.
Yusuf, Badronnisa
Mohammad, Thamer Ahmad
Dhahad, Hayder A.
author_sort Alawee, Wissam H.
title Variation of coefficient of friction and friction head losses along a pipe with multiple outlets
title_short Variation of coefficient of friction and friction head losses along a pipe with multiple outlets
title_full Variation of coefficient of friction and friction head losses along a pipe with multiple outlets
title_fullStr Variation of coefficient of friction and friction head losses along a pipe with multiple outlets
title_full_unstemmed Variation of coefficient of friction and friction head losses along a pipe with multiple outlets
title_sort variation of coefficient of friction and friction head losses along a pipe with multiple outlets
publisher MDPI
publishDate 2020
url http://psasir.upm.edu.my/id/eprint/38120/1/38120.pdf
http://psasir.upm.edu.my/id/eprint/38120/
https://www.mdpi.com/2073-4441/12/3/844
_version_ 1665895955490144256