Optimal allocation of sen transformer for active power loss reduction

Reduction of active power loss is one of the main functions that are carried in power system control centers. The main purpose of transmission systems is efficiently handling power from generation stations to load centers. Yet, a considerable amount of power is lost in transmission network component...

Full description

Saved in:
Bibliographic Details
Main Authors: Mohamed, Salah Eldeen Gasim, Jasni, Jasronita, Mohd Radzi, Mohd Amran, Hizam, Hashim, Mirzaei, Maryam
Format: Conference or Workshop Item
Language:English
Published: IEEE 2014
Online Access:http://psasir.upm.edu.my/id/eprint/43145/1/Optimal%20allocation%20of%20Sen%20Transformer%20for%20active%20power%20loss%20reduction.pdf
http://psasir.upm.edu.my/id/eprint/43145/
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Universiti Putra Malaysia
Language: English
id my.upm.eprints.43145
record_format eprints
spelling my.upm.eprints.431452016-05-18T02:55:39Z http://psasir.upm.edu.my/id/eprint/43145/ Optimal allocation of sen transformer for active power loss reduction Mohamed, Salah Eldeen Gasim Jasni, Jasronita Mohd Radzi, Mohd Amran Hizam, Hashim Mirzaei, Maryam Reduction of active power loss is one of the main functions that are carried in power system control centers. The main purpose of transmission systems is efficiently handling power from generation stations to load centers. Yet, a considerable amount of power is lost in transmission network components. As a corrective action, power flow redistribution in transmission lines using appropriate power flow control devices is useful to increase the transmission efficiency. However, the inserted power flow control devices themselves consume power. Thus, if not optimally sited, their own power loss may overcome the loss reduction which is obtained by their action, and as a consequence may increase the power loss further. Optimal allocation of these devices is critical to ensure fulfillment of the proposed goals. In this work, optimally placed Sen Transformer (ST) is suggested for power loss reduction considering security constraints. ST is modelled under MATLAB/SIMULINK, and optimally located using active power loss sensitivity index. The method is validated using IEEE-6 bus system and the results are encouraging. IEEE 2014 Conference or Workshop Item PeerReviewed application/pdf en http://psasir.upm.edu.my/id/eprint/43145/1/Optimal%20allocation%20of%20Sen%20Transformer%20for%20active%20power%20loss%20reduction.pdf Mohamed, Salah Eldeen Gasim and Jasni, Jasronita and Mohd Radzi, Mohd Amran and Hizam, Hashim and Mirzaei, Maryam (2014) Optimal allocation of sen transformer for active power loss reduction. In: 2014 IEEE International Conference on Power and Energy (PECon 2014), 1-3 Dec. 2014, Kuching, Sarawak, Malaysia. (pp. 59-64). 10.1109/PECON.2014.7062414
institution Universiti Putra Malaysia
building UPM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Putra Malaysia
content_source UPM Institutional Repository
url_provider http://psasir.upm.edu.my/
language English
description Reduction of active power loss is one of the main functions that are carried in power system control centers. The main purpose of transmission systems is efficiently handling power from generation stations to load centers. Yet, a considerable amount of power is lost in transmission network components. As a corrective action, power flow redistribution in transmission lines using appropriate power flow control devices is useful to increase the transmission efficiency. However, the inserted power flow control devices themselves consume power. Thus, if not optimally sited, their own power loss may overcome the loss reduction which is obtained by their action, and as a consequence may increase the power loss further. Optimal allocation of these devices is critical to ensure fulfillment of the proposed goals. In this work, optimally placed Sen Transformer (ST) is suggested for power loss reduction considering security constraints. ST is modelled under MATLAB/SIMULINK, and optimally located using active power loss sensitivity index. The method is validated using IEEE-6 bus system and the results are encouraging.
format Conference or Workshop Item
author Mohamed, Salah Eldeen Gasim
Jasni, Jasronita
Mohd Radzi, Mohd Amran
Hizam, Hashim
Mirzaei, Maryam
spellingShingle Mohamed, Salah Eldeen Gasim
Jasni, Jasronita
Mohd Radzi, Mohd Amran
Hizam, Hashim
Mirzaei, Maryam
Optimal allocation of sen transformer for active power loss reduction
author_facet Mohamed, Salah Eldeen Gasim
Jasni, Jasronita
Mohd Radzi, Mohd Amran
Hizam, Hashim
Mirzaei, Maryam
author_sort Mohamed, Salah Eldeen Gasim
title Optimal allocation of sen transformer for active power loss reduction
title_short Optimal allocation of sen transformer for active power loss reduction
title_full Optimal allocation of sen transformer for active power loss reduction
title_fullStr Optimal allocation of sen transformer for active power loss reduction
title_full_unstemmed Optimal allocation of sen transformer for active power loss reduction
title_sort optimal allocation of sen transformer for active power loss reduction
publisher IEEE
publishDate 2014
url http://psasir.upm.edu.my/id/eprint/43145/1/Optimal%20allocation%20of%20Sen%20Transformer%20for%20active%20power%20loss%20reduction.pdf
http://psasir.upm.edu.my/id/eprint/43145/
_version_ 1643833479414153216