An accurate setting for remapping process of foot plantar pressure
This paper present a precise and detailed study for the touch area on the foot based on amplifier gain settings of individual sensors that are distributed over the plantar insole area, the idea is to fill the insole area with sensor size areas that satisfy covering almost the foot touch area. The pr...
Saved in:
Main Authors: | , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
American Scientific Publishers
2015
|
Online Access: | http://psasir.upm.edu.my/id/eprint/43695/1/An%20accurate%20setting%20for%20remapping%20process%20of%20foot%20plantar%20pressure.pdf http://psasir.upm.edu.my/id/eprint/43695/ |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Institution: | Universiti Putra Malaysia |
Language: | English |
id |
my.upm.eprints.43695 |
---|---|
record_format |
eprints |
spelling |
my.upm.eprints.436952016-08-08T07:13:06Z http://psasir.upm.edu.my/id/eprint/43695/ An accurate setting for remapping process of foot plantar pressure Alwan, Omar Hussein Wan Hassan, Wan Zuha Che Soh, Azura Jaafar, Haslina This paper present a precise and detailed study for the touch area on the foot based on amplifier gain settings of individual sensors that are distributed over the plantar insole area, the idea is to fill the insole area with sensor size areas that satisfy covering almost the foot touch area. The procedure includes steps have to be implemented to achieve accurate reference values with respect to body weight. The values of individual sensor points have been evaluated for the both (Foot-Sensor-Insole-Ground) and (Foot-Sensor-Ground). It is found that, there is a wide range difference between the test points in each case and the existence of the insole reduced the pressure weight. A percentage value according to total body weight can be being assigned as the reference points in future studies. American Scientific Publishers 2015-10 Article PeerReviewed application/pdf en http://psasir.upm.edu.my/id/eprint/43695/1/An%20accurate%20setting%20for%20remapping%20process%20of%20foot%20plantar%20pressure.pdf Alwan, Omar Hussein and Wan Hassan, Wan Zuha and Che Soh, Azura and Jaafar, Haslina (2015) An accurate setting for remapping process of foot plantar pressure. Advanced Science, Engineering and Medicine, 7 (10). pp. 872-876. ISSN 2164-6627; ESSN: 2164-6635 10.1166/asem.2015.1787 |
institution |
Universiti Putra Malaysia |
building |
UPM Library |
collection |
Institutional Repository |
continent |
Asia |
country |
Malaysia |
content_provider |
Universiti Putra Malaysia |
content_source |
UPM Institutional Repository |
url_provider |
http://psasir.upm.edu.my/ |
language |
English |
description |
This paper present a precise and detailed study for the touch area on the foot based on amplifier gain settings of individual sensors that are distributed over the plantar insole area, the idea is to fill the insole area with sensor size areas that satisfy covering almost the foot touch area. The procedure includes steps have to be implemented to achieve accurate reference values with respect to body weight. The values of individual sensor points have been evaluated for the both (Foot-Sensor-Insole-Ground) and (Foot-Sensor-Ground). It is found that, there is a wide range difference between the test points in each case and the existence of the insole reduced the pressure weight. A percentage value according to total body weight can be being assigned as the reference points in future studies. |
format |
Article |
author |
Alwan, Omar Hussein Wan Hassan, Wan Zuha Che Soh, Azura Jaafar, Haslina |
spellingShingle |
Alwan, Omar Hussein Wan Hassan, Wan Zuha Che Soh, Azura Jaafar, Haslina An accurate setting for remapping process of foot plantar pressure |
author_facet |
Alwan, Omar Hussein Wan Hassan, Wan Zuha Che Soh, Azura Jaafar, Haslina |
author_sort |
Alwan, Omar Hussein |
title |
An accurate setting for remapping process of foot plantar pressure |
title_short |
An accurate setting for remapping process of foot plantar pressure |
title_full |
An accurate setting for remapping process of foot plantar pressure |
title_fullStr |
An accurate setting for remapping process of foot plantar pressure |
title_full_unstemmed |
An accurate setting for remapping process of foot plantar pressure |
title_sort |
accurate setting for remapping process of foot plantar pressure |
publisher |
American Scientific Publishers |
publishDate |
2015 |
url |
http://psasir.upm.edu.my/id/eprint/43695/1/An%20accurate%20setting%20for%20remapping%20process%20of%20foot%20plantar%20pressure.pdf http://psasir.upm.edu.my/id/eprint/43695/ |
_version_ |
1643833641692823552 |