Concerns of corrosive effects with respect to lightning protection systems

Lightning protection system elements need to be selected from materials which are resistant to corrosion and should be protected from fast degradation. However, over the time corrosion will take place in the presence of galvanically dissimilar metals in the same electrolyte (moisture). Historically,...

Full description

Saved in:
Bibliographic Details
Main Authors: Ghavamian, Aidin, Maghami, Mohammad Reza, Dehghan, Shayan, Gomes, Chandima
Format: Article
Published: Elsevier 2015
Online Access:http://psasir.upm.edu.my/id/eprint/44164/
https://www.sciencedirect.com/science/article/pii/S1350630715300613
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Universiti Putra Malaysia
id my.upm.eprints.44164
record_format eprints
spelling my.upm.eprints.441642023-12-25T11:15:28Z http://psasir.upm.edu.my/id/eprint/44164/ Concerns of corrosive effects with respect to lightning protection systems Ghavamian, Aidin Maghami, Mohammad Reza Dehghan, Shayan Gomes, Chandima Lightning protection system elements need to be selected from materials which are resistant to corrosion and should be protected from fast degradation. However, over the time corrosion will take place in the presence of galvanically dissimilar metals in the same electrolyte (moisture). Historically, copper, aluminium and copper alloys (including bronze and brass) have been used in lightning protection applications as these materials are highly conductive and abundantly available. Corrosive effects on system components are influenced by the environmental factors such as moisture, soil type and temperature that make the corrosion process highly complex in soil. As per many standards on the installation of lightning protection systems, combinations of materials that naturally form electrolytic couples shall not be used, for example copper and steel, especially in the presence of moisture, in which corrosion will be accelerated. Similarly, the conditions within soil will have adverse effects on the ground system elements. Down conductors entering corrosive soil must be protected against corrosion by a protective covering. The paper presents the causes of corrosion and recent developments in minimising the corrosion associated with lightning protection and grounding systems. Elsevier 2015 Article PeerReviewed Ghavamian, Aidin and Maghami, Mohammad Reza and Dehghan, Shayan and Gomes, Chandima (2015) Concerns of corrosive effects with respect to lightning protection systems. Engineering Failure Analysis, 57. pp. 434-443. ISSN 1350-6307; ESSN: 1873-1961 https://www.sciencedirect.com/science/article/pii/S1350630715300613 10.1016/j.engfailanal.2015.08.019
institution Universiti Putra Malaysia
building UPM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Putra Malaysia
content_source UPM Institutional Repository
url_provider http://psasir.upm.edu.my/
description Lightning protection system elements need to be selected from materials which are resistant to corrosion and should be protected from fast degradation. However, over the time corrosion will take place in the presence of galvanically dissimilar metals in the same electrolyte (moisture). Historically, copper, aluminium and copper alloys (including bronze and brass) have been used in lightning protection applications as these materials are highly conductive and abundantly available. Corrosive effects on system components are influenced by the environmental factors such as moisture, soil type and temperature that make the corrosion process highly complex in soil. As per many standards on the installation of lightning protection systems, combinations of materials that naturally form electrolytic couples shall not be used, for example copper and steel, especially in the presence of moisture, in which corrosion will be accelerated. Similarly, the conditions within soil will have adverse effects on the ground system elements. Down conductors entering corrosive soil must be protected against corrosion by a protective covering. The paper presents the causes of corrosion and recent developments in minimising the corrosion associated with lightning protection and grounding systems.
format Article
author Ghavamian, Aidin
Maghami, Mohammad Reza
Dehghan, Shayan
Gomes, Chandima
spellingShingle Ghavamian, Aidin
Maghami, Mohammad Reza
Dehghan, Shayan
Gomes, Chandima
Concerns of corrosive effects with respect to lightning protection systems
author_facet Ghavamian, Aidin
Maghami, Mohammad Reza
Dehghan, Shayan
Gomes, Chandima
author_sort Ghavamian, Aidin
title Concerns of corrosive effects with respect to lightning protection systems
title_short Concerns of corrosive effects with respect to lightning protection systems
title_full Concerns of corrosive effects with respect to lightning protection systems
title_fullStr Concerns of corrosive effects with respect to lightning protection systems
title_full_unstemmed Concerns of corrosive effects with respect to lightning protection systems
title_sort concerns of corrosive effects with respect to lightning protection systems
publisher Elsevier
publishDate 2015
url http://psasir.upm.edu.my/id/eprint/44164/
https://www.sciencedirect.com/science/article/pii/S1350630715300613
_version_ 1787137178470449152