Investigation on the effects of line parameters to the lightning performance of 132 kV Kuala Krai-Gua Musang transmission line
Lightning has been a major concern to the power system researchers as it may cause damage to the transmission line. One of the event that will cause lightning overvoltage and most likely to occur is backflashover. A study has been carried out to investigate the effects of line parameters such as gro...
Saved in:
Main Authors: | , |
---|---|
Format: | Conference or Workshop Item |
Language: | English |
Published: |
IEEE
2013
|
Online Access: | http://psasir.upm.edu.my/id/eprint/45015/1/Investigation%20on%20the%20effects%20of%20line%20parameters%20to%20the%20lightning%20performance%20of%20132%20kV%20Kuala%20Krai-Gua%20Musang%20transmission%20line.pdf http://psasir.upm.edu.my/id/eprint/45015/ |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Institution: | Universiti Putra Malaysia |
Language: | English |
id |
my.upm.eprints.45015 |
---|---|
record_format |
eprints |
spelling |
my.upm.eprints.450152020-08-04T02:40:58Z http://psasir.upm.edu.my/id/eprint/45015/ Investigation on the effects of line parameters to the lightning performance of 132 kV Kuala Krai-Gua Musang transmission line Sardi, Junainah Ab Kadir, Mohd Zainal Abidin Lightning has been a major concern to the power system researchers as it may cause damage to the transmission line. One of the event that will cause lightning overvoltage and most likely to occur is backflashover. A study has been carried out to investigate the effects of line parameters such as ground resistance, soil resistivity, tower surge impedance, tower height and number of shield wires to the values of tower top voltage, backflashover rate (BFR) and probability of transformer damage at substation. A sample of worst performance of transmission line in Peninsular Malaysia i.e. 132 kV Kuala Krai-Gua Musang transmission line data was obtained from Tenaga Nasional Berhad (TNB) for the purpose of backflashover analysis. Power System Computer Aided Design (PSCAD) software was used to model integral part of transmission line components such as insulator gap, tower and footing resistance followed by doing the backflashover simulation and analysis. Findings from the analysis imply that the values of BFR and probability of transformer damage are strongly influenced by the values of line parameters. Right selection of line parameters may reduce BFR and probability of transformer damage, thus improve the transmission line performance. Findings of this research can be useful guideline towards high voltage transmission line design and planning in Malaysia. IEEE 2013 Conference or Workshop Item PeerReviewed text en http://psasir.upm.edu.my/id/eprint/45015/1/Investigation%20on%20the%20effects%20of%20line%20parameters%20to%20the%20lightning%20performance%20of%20132%20kV%20Kuala%20Krai-Gua%20Musang%20transmission%20line.pdf Sardi, Junainah and Ab Kadir, Mohd Zainal Abidin (2013) Investigation on the effects of line parameters to the lightning performance of 132 kV Kuala Krai-Gua Musang transmission line. In: 2013 IEEE 7th International Power Engineering and Optimization Conference (PEOCO 2013), 3-4 June 2013, Langkawi, Kedah. (pp. 594-599). 10.1109/PEOCO.2013.6564617 |
institution |
Universiti Putra Malaysia |
building |
UPM Library |
collection |
Institutional Repository |
continent |
Asia |
country |
Malaysia |
content_provider |
Universiti Putra Malaysia |
content_source |
UPM Institutional Repository |
url_provider |
http://psasir.upm.edu.my/ |
language |
English |
description |
Lightning has been a major concern to the power system researchers as it may cause damage to the transmission line. One of the event that will cause lightning overvoltage and most likely to occur is backflashover. A study has been carried out to investigate the effects of line parameters such as ground resistance, soil resistivity, tower surge impedance, tower height and number of shield wires to the values of tower top voltage, backflashover rate (BFR) and probability of transformer damage at substation. A sample of worst performance of transmission line in Peninsular Malaysia i.e. 132 kV Kuala Krai-Gua Musang transmission line data was obtained from Tenaga Nasional Berhad (TNB) for the purpose of backflashover analysis. Power System Computer Aided Design (PSCAD) software was used to model integral part of transmission line components such as insulator gap, tower and footing resistance followed by doing the backflashover simulation and analysis. Findings from the analysis imply that the values of BFR and probability of transformer damage are strongly influenced by the values of line parameters. Right selection of line parameters may reduce BFR and probability of transformer damage, thus improve the transmission line performance. Findings of this research can be useful guideline towards high voltage transmission line design and planning in Malaysia. |
format |
Conference or Workshop Item |
author |
Sardi, Junainah Ab Kadir, Mohd Zainal Abidin |
spellingShingle |
Sardi, Junainah Ab Kadir, Mohd Zainal Abidin Investigation on the effects of line parameters to the lightning performance of 132 kV Kuala Krai-Gua Musang transmission line |
author_facet |
Sardi, Junainah Ab Kadir, Mohd Zainal Abidin |
author_sort |
Sardi, Junainah |
title |
Investigation on the effects of line parameters to the lightning performance of 132 kV Kuala Krai-Gua Musang transmission line |
title_short |
Investigation on the effects of line parameters to the lightning performance of 132 kV Kuala Krai-Gua Musang transmission line |
title_full |
Investigation on the effects of line parameters to the lightning performance of 132 kV Kuala Krai-Gua Musang transmission line |
title_fullStr |
Investigation on the effects of line parameters to the lightning performance of 132 kV Kuala Krai-Gua Musang transmission line |
title_full_unstemmed |
Investigation on the effects of line parameters to the lightning performance of 132 kV Kuala Krai-Gua Musang transmission line |
title_sort |
investigation on the effects of line parameters to the lightning performance of 132 kv kuala krai-gua musang transmission line |
publisher |
IEEE |
publishDate |
2013 |
url |
http://psasir.upm.edu.my/id/eprint/45015/1/Investigation%20on%20the%20effects%20of%20line%20parameters%20to%20the%20lightning%20performance%20of%20132%20kV%20Kuala%20Krai-Gua%20Musang%20transmission%20line.pdf http://psasir.upm.edu.my/id/eprint/45015/ |
_version_ |
1675328725237891072 |