Considering the effects of a cross-arm on a contaminated polymer insulator at different angles

This paper considers the effects of a cross-arm on a contaminated polymer insulator at different angles (90°, 60° and 45°) with negative and positive impulses. An experiment was conducted using a 10 kV polymer insulator that was contaminated with 4 % salt (a mixture of distilled water and sodium chl...

Full description

Saved in:
Bibliographic Details
Main Authors: Jamaludin, Farah Adilah, Abd Rahman, Muhammad Syahmi, Izadi, Mahdi, Ab Kadir, Mohd Zainal Abidin, Azis, Norhafiz, Jasni, Jasronita
Format: Conference or Workshop Item
Language:English
Published: IEEE 2015
Online Access:http://psasir.upm.edu.my/id/eprint/47635/1/Considering%20the%20effects%20of%20a%20cross-arm%20on%20a%20contaminated%20polymer%20insulator%20at%20different%20angles.pdf
http://psasir.upm.edu.my/id/eprint/47635/
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Universiti Putra Malaysia
Language: English
id my.upm.eprints.47635
record_format eprints
spelling my.upm.eprints.476352019-04-16T07:20:00Z http://psasir.upm.edu.my/id/eprint/47635/ Considering the effects of a cross-arm on a contaminated polymer insulator at different angles Jamaludin, Farah Adilah Abd Rahman, Muhammad Syahmi Izadi, Mahdi Ab Kadir, Mohd Zainal Abidin Azis, Norhafiz Jasni, Jasronita This paper considers the effects of a cross-arm on a contaminated polymer insulator at different angles (90°, 60° and 45°) with negative and positive impulses. An experiment was conducted using a 10 kV polymer insulator that was contaminated with 4 % salt (a mixture of distilled water and sodium chloride). From the experiment, the behaviour of the voltage breakdown and leakage current of the contaminated insulator positioned at different angles from the cross-arm was evaluated under different impulse polarities. The results show that the values of the breakdown voltage and leakage current decrease with angle when using the 90° angle as a reference. The reason for this study into the effects of the cross-arm on a contaminated polymer insulator is because in the real case, when the insulators are installed on an angle tower, the forces or tensions due to the weather conditions (especially under strong winds) and from the distribution lines themselves will force the installed insulators to be tilted from its original 90° angle position. IEEE 2015 Conference or Workshop Item PeerReviewed application/pdf en http://psasir.upm.edu.my/id/eprint/47635/1/Considering%20the%20effects%20of%20a%20cross-arm%20on%20a%20contaminated%20polymer%20insulator%20at%20different%20angles.pdf Jamaludin, Farah Adilah and Abd Rahman, Muhammad Syahmi and Izadi, Mahdi and Ab Kadir, Mohd Zainal Abidin and Azis, Norhafiz and Jasni, Jasronita (2015) Considering the effects of a cross-arm on a contaminated polymer insulator at different angles. In: 2015 IEEE Conference on Energy Conversion (CENCON), 19-20 Oct. 2015, Johor Bahru, Malaysia. (pp. 263-267). 10.1109/CENCON.2015.7409551
institution Universiti Putra Malaysia
building UPM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Putra Malaysia
content_source UPM Institutional Repository
url_provider http://psasir.upm.edu.my/
language English
description This paper considers the effects of a cross-arm on a contaminated polymer insulator at different angles (90°, 60° and 45°) with negative and positive impulses. An experiment was conducted using a 10 kV polymer insulator that was contaminated with 4 % salt (a mixture of distilled water and sodium chloride). From the experiment, the behaviour of the voltage breakdown and leakage current of the contaminated insulator positioned at different angles from the cross-arm was evaluated under different impulse polarities. The results show that the values of the breakdown voltage and leakage current decrease with angle when using the 90° angle as a reference. The reason for this study into the effects of the cross-arm on a contaminated polymer insulator is because in the real case, when the insulators are installed on an angle tower, the forces or tensions due to the weather conditions (especially under strong winds) and from the distribution lines themselves will force the installed insulators to be tilted from its original 90° angle position.
format Conference or Workshop Item
author Jamaludin, Farah Adilah
Abd Rahman, Muhammad Syahmi
Izadi, Mahdi
Ab Kadir, Mohd Zainal Abidin
Azis, Norhafiz
Jasni, Jasronita
spellingShingle Jamaludin, Farah Adilah
Abd Rahman, Muhammad Syahmi
Izadi, Mahdi
Ab Kadir, Mohd Zainal Abidin
Azis, Norhafiz
Jasni, Jasronita
Considering the effects of a cross-arm on a contaminated polymer insulator at different angles
author_facet Jamaludin, Farah Adilah
Abd Rahman, Muhammad Syahmi
Izadi, Mahdi
Ab Kadir, Mohd Zainal Abidin
Azis, Norhafiz
Jasni, Jasronita
author_sort Jamaludin, Farah Adilah
title Considering the effects of a cross-arm on a contaminated polymer insulator at different angles
title_short Considering the effects of a cross-arm on a contaminated polymer insulator at different angles
title_full Considering the effects of a cross-arm on a contaminated polymer insulator at different angles
title_fullStr Considering the effects of a cross-arm on a contaminated polymer insulator at different angles
title_full_unstemmed Considering the effects of a cross-arm on a contaminated polymer insulator at different angles
title_sort considering the effects of a cross-arm on a contaminated polymer insulator at different angles
publisher IEEE
publishDate 2015
url http://psasir.upm.edu.my/id/eprint/47635/1/Considering%20the%20effects%20of%20a%20cross-arm%20on%20a%20contaminated%20polymer%20insulator%20at%20different%20angles.pdf
http://psasir.upm.edu.my/id/eprint/47635/
_version_ 1643833937111285760