Relationship between capacitance values and diesel contamination levels in crude palm oil

Measurement of crude palm oil (CPO) contamination is a major concern in CPO quality monitoring. In this study, capacitive sensing technique was used to measure diesel contamination levels in CPO. This technique was choosing because it is provide immediately real-time information of contamination in...

Full description

Saved in:
Bibliographic Details
Main Authors: Chin @ Hashim, Nur Fizura, Abd Aziz, Samsuzana, Saringat, Hafizan
Format: Conference or Workshop Item
Language:English
Published: Faculty of Engineering, Universiti Putra Malaysia 2012
Online Access:http://psasir.upm.edu.my/id/eprint/50662/1/_TechnicalPapers_CAFEi2012_68.pdf
http://psasir.upm.edu.my/id/eprint/50662/
http://cafei.upm.edu.my/download.php?filename=/TechnicalPapers/CAFEi2012_68.pdf
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Universiti Putra Malaysia
Language: English
id my.upm.eprints.50662
record_format eprints
spelling my.upm.eprints.506622017-03-02T06:11:01Z http://psasir.upm.edu.my/id/eprint/50662/ Relationship between capacitance values and diesel contamination levels in crude palm oil Chin @ Hashim, Nur Fizura Abd Aziz, Samsuzana Saringat, Hafizan Measurement of crude palm oil (CPO) contamination is a major concern in CPO quality monitoring. In this study, capacitive sensing technique was used to measure diesel contamination levels in CPO. This technique was choosing because it is provide immediately real-time information of contamination in CPO. Low cost capacitive sensing system was developed in this study by using AD7746 capacitance to digital converter. The effect of diesel contamination levels range from 0% to 50% in CPO and the output of capacitance sensor at a room temperature (25°C) were investigated. The results showed that capacitance value decreased with increases in diesel contamination levels. The regression model for this research y=0.0002x2-0.0125x+0.9360 with r2 value of 0.96. These results indicated that capacitive sensing technique has potential for CPO quality monitoring. Faculty of Engineering, Universiti Putra Malaysia 2012 Conference or Workshop Item PeerReviewed application/pdf en http://psasir.upm.edu.my/id/eprint/50662/1/_TechnicalPapers_CAFEi2012_68.pdf Chin @ Hashim, Nur Fizura and Abd Aziz, Samsuzana and Saringat, Hafizan (2012) Relationship between capacitance values and diesel contamination levels in crude palm oil. In: International Conference on Agricultural and Food Engineering for Life (Cafei2012), 26-28 Nov. 2012, Palm Garden Hotel, Putrajaya. (pp. 219-224). http://cafei.upm.edu.my/download.php?filename=/TechnicalPapers/CAFEi2012_68.pdf
institution Universiti Putra Malaysia
building UPM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Putra Malaysia
content_source UPM Institutional Repository
url_provider http://psasir.upm.edu.my/
language English
description Measurement of crude palm oil (CPO) contamination is a major concern in CPO quality monitoring. In this study, capacitive sensing technique was used to measure diesel contamination levels in CPO. This technique was choosing because it is provide immediately real-time information of contamination in CPO. Low cost capacitive sensing system was developed in this study by using AD7746 capacitance to digital converter. The effect of diesel contamination levels range from 0% to 50% in CPO and the output of capacitance sensor at a room temperature (25°C) were investigated. The results showed that capacitance value decreased with increases in diesel contamination levels. The regression model for this research y=0.0002x2-0.0125x+0.9360 with r2 value of 0.96. These results indicated that capacitive sensing technique has potential for CPO quality monitoring.
format Conference or Workshop Item
author Chin @ Hashim, Nur Fizura
Abd Aziz, Samsuzana
Saringat, Hafizan
spellingShingle Chin @ Hashim, Nur Fizura
Abd Aziz, Samsuzana
Saringat, Hafizan
Relationship between capacitance values and diesel contamination levels in crude palm oil
author_facet Chin @ Hashim, Nur Fizura
Abd Aziz, Samsuzana
Saringat, Hafizan
author_sort Chin @ Hashim, Nur Fizura
title Relationship between capacitance values and diesel contamination levels in crude palm oil
title_short Relationship between capacitance values and diesel contamination levels in crude palm oil
title_full Relationship between capacitance values and diesel contamination levels in crude palm oil
title_fullStr Relationship between capacitance values and diesel contamination levels in crude palm oil
title_full_unstemmed Relationship between capacitance values and diesel contamination levels in crude palm oil
title_sort relationship between capacitance values and diesel contamination levels in crude palm oil
publisher Faculty of Engineering, Universiti Putra Malaysia
publishDate 2012
url http://psasir.upm.edu.my/id/eprint/50662/1/_TechnicalPapers_CAFEi2012_68.pdf
http://psasir.upm.edu.my/id/eprint/50662/
http://cafei.upm.edu.my/download.php?filename=/TechnicalPapers/CAFEi2012_68.pdf
_version_ 1643834729226567680