Monthly analysis of PM10 in ambient air of Klang Valley, Malaysia

The urbanization in Klang Valley, Peninsular Malaysia over the last decades has induce the atmospheric pollution’s risk resulted to negative impact on the environment. The aims of this paper are to identify the spatial-temporal relationship of particulate matter (PM10), to determine the characterist...

Full description

Saved in:
Bibliographic Details
Main Authors: Jamalani, Mohd Asrul, Abdullah, Ahmad Makmom, Azid, Azman, Ramli, Mohammad Firuz, Baharudin, Mohd Rafee, Mohammed Bose, Mahmud, Elhadi, Rashieda Elawad, Ben Youssef, Khaleed Ali Ahmed, Gnadimzadeh, Azadeh, Gumel, Danladi Yusuf
Format: Article
Language:English
Published: The Malaysian Analytical Sciences Society, Universiti Kebangsaan Malaysia 2016
Online Access:http://psasir.upm.edu.my/id/eprint/53333/1/Monthly%20analysis%20of%20PM10%20in%20ambient%20air%20of%20Klang%20Valley%2C%20Malaysia.pdf
http://psasir.upm.edu.my/id/eprint/53333/
http://www.ukm.my/mjas/mjas2017/
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Universiti Putra Malaysia
Language: English
Description
Summary:The urbanization in Klang Valley, Peninsular Malaysia over the last decades has induce the atmospheric pollution’s risk resulted to negative impact on the environment. The aims of this paper are to identify the spatial-temporal relationship of particulate matter (PM10), to determine the characteristic of each location and to classify hierarchical of the location in relation to their impact on PM10 concentration in Klang Valley. The Spearman correlation test indicate that there was strong significant relationship between all the locations (> 0.7; p < 0.001) and moderate relationship between Petaling Jaya-Kajang and Kajang-Shah Alam (< 0.7; p < 0.001). The principal component analysis (PCA) identifies all four locations have been affected by PM10 which were determined as one of the pollutant that deteriorated the air quality. Cluster analysis (CA) has classified the PM10 pattern into three (3) different classes; Class 1 (Klang), Class 2 (Petaling Jaya and Kajang) and Class 3 (Shah Alam) based on location. Further analysis of CA would be able to classify the PM10 classes into groups depending on their dissimilarities characteristic. Thus, possible period of extreme air quality degradation could be identified. Therefore, statistical and envirometric techniques have proved the impact of the various location on increasing concentration of PM10.