Strut effectiveness factor for reinforced concrete deep beamsunder dynamic loading condition

In a current study, a new strut effectiveness factor based on Strut-and-Tie Model (STM) is proposed to assess the ultimate shear strength of reinforced concrete (RC) deep beam subjected to dynamic loads. The derivation of the new effectiveness factor of concrete struts is based on Mohr–Coulomb crite...

Full description

Saved in:
Bibliographic Details
Main Authors: Hanoon, Ammar Nasiri, Jaafar, Mohd. Saleh, Hejazi, Farzad, Abd Aziz, Farah Nora Aznieta
Format: Article
Language:English
Published: 2214-3998 2016
Online Access:http://psasir.upm.edu.my/id/eprint/53915/1/Strut%20effectiveness%20factor%20for%20reinforced%20concrete%20deep%20beams%20under%20dynamic%20loading%20conditions.pdf
http://psasir.upm.edu.my/id/eprint/53915/
https://www.sciencedirect.com/science/article/pii/S2214399816300182
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Universiti Putra Malaysia
Language: English
id my.upm.eprints.53915
record_format eprints
spelling my.upm.eprints.539152018-02-21T03:57:54Z http://psasir.upm.edu.my/id/eprint/53915/ Strut effectiveness factor for reinforced concrete deep beamsunder dynamic loading condition Hanoon, Ammar Nasiri Jaafar, Mohd. Saleh Hejazi, Farzad Abd Aziz, Farah Nora Aznieta In a current study, a new strut effectiveness factor based on Strut-and-Tie Model (STM) is proposed to assess the ultimate shear strength of reinforced concrete (RC) deep beam subjected to dynamic loads. The derivation of the new effectiveness factor of concrete struts is based on Mohr–Coulomb criterion failure. Two types of concrete failure, diagonal splitting and concrete crushing failure modes, are proposed and examined. The modification of the proposed model is simulated in a MATLABSIMULINK environment. The proposed model exhibits efficiency in assessing dynamic shear resistance for deep beams. Moreover, a parametric study is then conducted to examine the effect of flexural reinforcement ratio, transverse reinforcement and shear-span to depth ratio on shear behavior of RC deep beams with consideration of the changes in strain rate. The proposed effectiveness factor is validated by utilizing the experimental results obtained from the literature and shows good accuracy for prediction the shear strength of reinforced concrete deep beams under different loading conditions. 2214-3998 2016-12 Article PeerReviewed text en http://psasir.upm.edu.my/id/eprint/53915/1/Strut%20effectiveness%20factor%20for%20reinforced%20concrete%20deep%20beams%20under%20dynamic%20loading%20conditions.pdf Hanoon, Ammar Nasiri and Jaafar, Mohd. Saleh and Hejazi, Farzad and Abd Aziz, Farah Nora Aznieta (2016) Strut effectiveness factor for reinforced concrete deep beamsunder dynamic loading condition. Case Studies in Structural Engineering, 6. pp. 84-102. ISSN Elsevier BV https://www.sciencedirect.com/science/article/pii/S2214399816300182 10.1016/j.csse.2016.08.001
institution Universiti Putra Malaysia
building UPM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Putra Malaysia
content_source UPM Institutional Repository
url_provider http://psasir.upm.edu.my/
language English
description In a current study, a new strut effectiveness factor based on Strut-and-Tie Model (STM) is proposed to assess the ultimate shear strength of reinforced concrete (RC) deep beam subjected to dynamic loads. The derivation of the new effectiveness factor of concrete struts is based on Mohr–Coulomb criterion failure. Two types of concrete failure, diagonal splitting and concrete crushing failure modes, are proposed and examined. The modification of the proposed model is simulated in a MATLABSIMULINK environment. The proposed model exhibits efficiency in assessing dynamic shear resistance for deep beams. Moreover, a parametric study is then conducted to examine the effect of flexural reinforcement ratio, transverse reinforcement and shear-span to depth ratio on shear behavior of RC deep beams with consideration of the changes in strain rate. The proposed effectiveness factor is validated by utilizing the experimental results obtained from the literature and shows good accuracy for prediction the shear strength of reinforced concrete deep beams under different loading conditions.
format Article
author Hanoon, Ammar Nasiri
Jaafar, Mohd. Saleh
Hejazi, Farzad
Abd Aziz, Farah Nora Aznieta
spellingShingle Hanoon, Ammar Nasiri
Jaafar, Mohd. Saleh
Hejazi, Farzad
Abd Aziz, Farah Nora Aznieta
Strut effectiveness factor for reinforced concrete deep beamsunder dynamic loading condition
author_facet Hanoon, Ammar Nasiri
Jaafar, Mohd. Saleh
Hejazi, Farzad
Abd Aziz, Farah Nora Aznieta
author_sort Hanoon, Ammar Nasiri
title Strut effectiveness factor for reinforced concrete deep beamsunder dynamic loading condition
title_short Strut effectiveness factor for reinforced concrete deep beamsunder dynamic loading condition
title_full Strut effectiveness factor for reinforced concrete deep beamsunder dynamic loading condition
title_fullStr Strut effectiveness factor for reinforced concrete deep beamsunder dynamic loading condition
title_full_unstemmed Strut effectiveness factor for reinforced concrete deep beamsunder dynamic loading condition
title_sort strut effectiveness factor for reinforced concrete deep beamsunder dynamic loading condition
publisher 2214-3998
publishDate 2016
url http://psasir.upm.edu.my/id/eprint/53915/1/Strut%20effectiveness%20factor%20for%20reinforced%20concrete%20deep%20beams%20under%20dynamic%20loading%20conditions.pdf
http://psasir.upm.edu.my/id/eprint/53915/
https://www.sciencedirect.com/science/article/pii/S2214399816300182
_version_ 1643835522741698560