DC-link capacitor voltage regulation with effort-reduction fuzzy logic control for three-level inverter-based shunt active power filter
Shunt active power filter (SAPF) is the most effective solution for current harmonics. In its controller, DC-link capacitor voltage regulation algorithm with either proportional-integral (PI) or fuzzy logic control (FLC) technique has played a significant role in maintaining a constant DC voltage ac...
Saved in:
Main Authors: | , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Universiti Putra Malaysia Press
2017
|
Online Access: | http://psasir.upm.edu.my/id/eprint/55863/1/2-JTS%28S%29-0116-2016-4thProof.pdf http://psasir.upm.edu.my/id/eprint/55863/ http://www.pertanika.upm.edu.my/Pertanika%20PAPERS/JST%20Vol.%2025%20(S)%20Feb.%202017/2-JTS(S)-0116-2016-4thProof.pdf |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Institution: | Universiti Putra Malaysia |
Language: | English |
id |
my.upm.eprints.55863 |
---|---|
record_format |
eprints |
spelling |
my.upm.eprints.558632017-06-30T09:49:49Z http://psasir.upm.edu.my/id/eprint/55863/ DC-link capacitor voltage regulation with effort-reduction fuzzy logic control for three-level inverter-based shunt active power filter Mailah, Nashiren Farzilah Yap, Hoon Mohd Radzi, Mohd Amran Shunt active power filter (SAPF) is the most effective solution for current harmonics. In its controller, DC-link capacitor voltage regulation algorithm with either proportional-integral (PI) or fuzzy logic control (FLC) technique has played a significant role in maintaining a constant DC voltage across all the DC-link capacitors. However, PI technique performs poorly with high overshoot and significant time delay under dynamic state conditions, as its parameters are difficult to be tuned without requiring complete knowledge of the designated system. Although FLC technique has been developed to overcome limitations of PI technique, it is mostly developed with high complexity thereby increases computational burden of the designed controller. This paper presents a fuzzy-based DC-link capacitor voltage regulation algorithm with reduced computational efforts to enhance performance of three-phase three-level neutral-point diode clamped (NPC) inverter-based SAPF in overall DC-link voltage regulation. The proposed method is called effort-reduction FLC technique. The proposed algorithm is developed and evaluated in MATLAB-Simulink. Moreover, conventional algorithm with PI technique is tested for comparison purposes. Simulation results have confirmed improvement achieved by the proposed algorithm in comparison to the conventional algorithm. Universiti Putra Malaysia Press 2017 Article PeerReviewed application/pdf en http://psasir.upm.edu.my/id/eprint/55863/1/2-JTS%28S%29-0116-2016-4thProof.pdf Mailah, Nashiren Farzilah and Yap, Hoon and Mohd Radzi, Mohd Amran (2017) DC-link capacitor voltage regulation with effort-reduction fuzzy logic control for three-level inverter-based shunt active power filter. Pertanika Journal of Science & Technology, 25 (spec. Feb.). pp. 11-20. ISSN 0128-7680; ESSN: 2231-8526 http://www.pertanika.upm.edu.my/Pertanika%20PAPERS/JST%20Vol.%2025%20(S)%20Feb.%202017/2-JTS(S)-0116-2016-4thProof.pdf |
institution |
Universiti Putra Malaysia |
building |
UPM Library |
collection |
Institutional Repository |
continent |
Asia |
country |
Malaysia |
content_provider |
Universiti Putra Malaysia |
content_source |
UPM Institutional Repository |
url_provider |
http://psasir.upm.edu.my/ |
language |
English |
description |
Shunt active power filter (SAPF) is the most effective solution for current harmonics. In its controller, DC-link capacitor voltage regulation algorithm with either proportional-integral (PI) or fuzzy logic control (FLC) technique has played a significant role in maintaining a constant DC voltage across all the DC-link capacitors. However, PI technique performs poorly with high overshoot and significant time delay under dynamic state conditions, as its parameters are difficult to be tuned without requiring complete knowledge of the designated system. Although FLC technique has been developed to overcome limitations of PI technique, it is mostly developed with high complexity thereby increases computational burden of the designed controller. This paper presents a fuzzy-based DC-link capacitor voltage regulation algorithm with reduced computational efforts to enhance performance of three-phase three-level neutral-point diode clamped (NPC) inverter-based SAPF in overall DC-link voltage regulation. The proposed method is called effort-reduction FLC technique. The proposed algorithm is developed and evaluated in MATLAB-Simulink. Moreover, conventional algorithm with PI technique is tested for comparison purposes. Simulation results have confirmed improvement achieved by the proposed algorithm in comparison to the conventional algorithm. |
format |
Article |
author |
Mailah, Nashiren Farzilah Yap, Hoon Mohd Radzi, Mohd Amran |
spellingShingle |
Mailah, Nashiren Farzilah Yap, Hoon Mohd Radzi, Mohd Amran DC-link capacitor voltage regulation with effort-reduction fuzzy logic control for three-level inverter-based shunt active power filter |
author_facet |
Mailah, Nashiren Farzilah Yap, Hoon Mohd Radzi, Mohd Amran |
author_sort |
Mailah, Nashiren Farzilah |
title |
DC-link capacitor voltage regulation with effort-reduction fuzzy logic control for three-level inverter-based shunt active power filter |
title_short |
DC-link capacitor voltage regulation with effort-reduction fuzzy logic control for three-level inverter-based shunt active power filter |
title_full |
DC-link capacitor voltage regulation with effort-reduction fuzzy logic control for three-level inverter-based shunt active power filter |
title_fullStr |
DC-link capacitor voltage regulation with effort-reduction fuzzy logic control for three-level inverter-based shunt active power filter |
title_full_unstemmed |
DC-link capacitor voltage regulation with effort-reduction fuzzy logic control for three-level inverter-based shunt active power filter |
title_sort |
dc-link capacitor voltage regulation with effort-reduction fuzzy logic control for three-level inverter-based shunt active power filter |
publisher |
Universiti Putra Malaysia Press |
publishDate |
2017 |
url |
http://psasir.upm.edu.my/id/eprint/55863/1/2-JTS%28S%29-0116-2016-4thProof.pdf http://psasir.upm.edu.my/id/eprint/55863/ http://www.pertanika.upm.edu.my/Pertanika%20PAPERS/JST%20Vol.%2025%20(S)%20Feb.%202017/2-JTS(S)-0116-2016-4thProof.pdf |
_version_ |
1643836020611874816 |