Suppression of total harmonic distortion using single-phase shunt active power filter with fuzzy logic controller

In the previous years, electrical power system equipment and devices were designed to produce purely sinusoidal voltage and current wave forms. But nowadays, with much interest and wide spreads of power electronics equipment and devices utilized for industrial, commercials and residential consumers,...

Full description

Saved in:
Bibliographic Details
Main Author: Usman, Hamisu
Format: Thesis
Language:English
Published: 2013
Online Access:http://psasir.upm.edu.my/id/eprint/56096/1/FK%202013%2089RR.pdf
http://psasir.upm.edu.my/id/eprint/56096/
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Universiti Putra Malaysia
Language: English
id my.upm.eprints.56096
record_format eprints
spelling my.upm.eprints.560962017-07-20T07:41:21Z http://psasir.upm.edu.my/id/eprint/56096/ Suppression of total harmonic distortion using single-phase shunt active power filter with fuzzy logic controller Usman, Hamisu In the previous years, electrical power system equipment and devices were designed to produce purely sinusoidal voltage and current wave forms. But nowadays, with much interest and wide spreads of power electronics equipment and devices utilized for industrial, commercials and residential consumers, these equipment and other electronics devices can no longer operate with an ideal current and voltage waveform,because of the non-linearity of the equipment and devices in nature, that draw harmonics currents and voltages from the supply. With this, traditional LC passive filters were first introduced to mitigate harmonics currents/voltages and reactive power produced by non-linear loads. But passive filters are limited in operation due to its limitations such as heavy in sizes, bulky and a tendency for parallel and series resonances with supply impedance. Due to the limitations of passive filters, active power filters are now the dynamic and viable solution to suppress current harmonics and reactive power drawn by non-linear loads. In this thesis, the modeling and simulation of single-phase shunt active power filter to mitigate the unwanted harmonics currents/voltages and reactive power drawn by non-linear loads are proposed. Fuzzy logic controller (FLC) was used to control the active filter, because of its simplicity and does not require any accurate mathematical model. Simulations arecarried out in MATLAB/SIMULINK and SIMPOWER tool box environment. In the simulation, synchronous reference frame was used to extract the harmonic reference current produced by the non-linear loads. The simulation results were validated with the experimental results of the hardware proto- type in the laboratory. Digital signal processor DSP TMS320F28335 was used in order to demonstrate the feasibility and good performance of the proposed control algorithm. The total harmonics distortions (THD %) for the simulation results are within the IEEE 519-1992 harmonic standard. While the experimental results does not comply with the recommended IEEE 519-1992 harmonic standard limits because of the real time hardware implementation and losses within the real time components. 2013-10 Thesis NonPeerReviewed application/pdf en http://psasir.upm.edu.my/id/eprint/56096/1/FK%202013%2089RR.pdf Usman, Hamisu (2013) Suppression of total harmonic distortion using single-phase shunt active power filter with fuzzy logic controller. Masters thesis, Universiti Putra Malaysia.
institution Universiti Putra Malaysia
building UPM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Putra Malaysia
content_source UPM Institutional Repository
url_provider http://psasir.upm.edu.my/
language English
description In the previous years, electrical power system equipment and devices were designed to produce purely sinusoidal voltage and current wave forms. But nowadays, with much interest and wide spreads of power electronics equipment and devices utilized for industrial, commercials and residential consumers, these equipment and other electronics devices can no longer operate with an ideal current and voltage waveform,because of the non-linearity of the equipment and devices in nature, that draw harmonics currents and voltages from the supply. With this, traditional LC passive filters were first introduced to mitigate harmonics currents/voltages and reactive power produced by non-linear loads. But passive filters are limited in operation due to its limitations such as heavy in sizes, bulky and a tendency for parallel and series resonances with supply impedance. Due to the limitations of passive filters, active power filters are now the dynamic and viable solution to suppress current harmonics and reactive power drawn by non-linear loads. In this thesis, the modeling and simulation of single-phase shunt active power filter to mitigate the unwanted harmonics currents/voltages and reactive power drawn by non-linear loads are proposed. Fuzzy logic controller (FLC) was used to control the active filter, because of its simplicity and does not require any accurate mathematical model. Simulations arecarried out in MATLAB/SIMULINK and SIMPOWER tool box environment. In the simulation, synchronous reference frame was used to extract the harmonic reference current produced by the non-linear loads. The simulation results were validated with the experimental results of the hardware proto- type in the laboratory. Digital signal processor DSP TMS320F28335 was used in order to demonstrate the feasibility and good performance of the proposed control algorithm. The total harmonics distortions (THD %) for the simulation results are within the IEEE 519-1992 harmonic standard. While the experimental results does not comply with the recommended IEEE 519-1992 harmonic standard limits because of the real time hardware implementation and losses within the real time components.
format Thesis
author Usman, Hamisu
spellingShingle Usman, Hamisu
Suppression of total harmonic distortion using single-phase shunt active power filter with fuzzy logic controller
author_facet Usman, Hamisu
author_sort Usman, Hamisu
title Suppression of total harmonic distortion using single-phase shunt active power filter with fuzzy logic controller
title_short Suppression of total harmonic distortion using single-phase shunt active power filter with fuzzy logic controller
title_full Suppression of total harmonic distortion using single-phase shunt active power filter with fuzzy logic controller
title_fullStr Suppression of total harmonic distortion using single-phase shunt active power filter with fuzzy logic controller
title_full_unstemmed Suppression of total harmonic distortion using single-phase shunt active power filter with fuzzy logic controller
title_sort suppression of total harmonic distortion using single-phase shunt active power filter with fuzzy logic controller
publishDate 2013
url http://psasir.upm.edu.my/id/eprint/56096/1/FK%202013%2089RR.pdf
http://psasir.upm.edu.my/id/eprint/56096/
_version_ 1643836089378537472