Microwave‐based biosensor for glucose detection
In this project, microwave‐based biosensor for glucose detection has been studied. The study is based on the dielectric properties changes at microwave frequency for glucose‐enzyme reaction. Glucose interaction with glucose oxidase (GOD) produced gluconic acid and hydrogen peroxide. The reaction of...
Saved in:
Main Authors: | , , |
---|---|
Format: | Conference or Workshop Item |
Language: | English |
Published: |
American Institute of Physics
2009
|
Online Access: | http://psasir.upm.edu.my/id/eprint/57283/1/Microwave%E2%80%90based%20biosensor%20for%20glucose%20detection.pdf http://psasir.upm.edu.my/id/eprint/57283/ |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Institution: | Universiti Putra Malaysia |
Language: | English |
id |
my.upm.eprints.57283 |
---|---|
record_format |
eprints |
spelling |
my.upm.eprints.572832017-09-26T03:59:02Z http://psasir.upm.edu.my/id/eprint/57283/ Microwave‐based biosensor for glucose detection Md Salim, Nora Salina Khalid, Kaida Yusof, Nor Azah In this project, microwave‐based biosensor for glucose detection has been studied. The study is based on the dielectric properties changes at microwave frequency for glucose‐enzyme reaction. Glucose interaction with glucose oxidase (GOD) produced gluconic acid and hydrogen peroxide. The reaction of the glucose solutions with an enzyme was carried out in 1:3 of glucose and enzyme respectively. The measurements were done using the Open Ended Coaxial Probe (OECP) coupled with computer controlled software automated network analyzer (ANA) with frequency range from 200MHz to 20GHz at room temperature (25 °C). The differences of enzyme and glucose‐enzyme reaction were calculated and plotted. In the microwave interaction with the glucose‐enzyme reaction, ionic conduction and dipole molecules was detected at 0.99GHz and 16.44GHz respectively based on changes of dielectric loss factor. American Institute of Physics 2009 Conference or Workshop Item PeerReviewed application/pdf en http://psasir.upm.edu.my/id/eprint/57283/1/Microwave%E2%80%90based%20biosensor%20for%20glucose%20detection.pdf Md Salim, Nora Salina and Khalid, Kaida and Yusof, Nor Azah (2009) Microwave‐based biosensor for glucose detection. In: Progress of Physics Research in Malaysia (PERFIK2009), 7-9 Dec. 2009, Melaka, Malaysia. (pp. 401-404). 10.1063/1.3469692 |
institution |
Universiti Putra Malaysia |
building |
UPM Library |
collection |
Institutional Repository |
continent |
Asia |
country |
Malaysia |
content_provider |
Universiti Putra Malaysia |
content_source |
UPM Institutional Repository |
url_provider |
http://psasir.upm.edu.my/ |
language |
English |
description |
In this project, microwave‐based biosensor for glucose detection has been studied. The study is based on the dielectric properties changes at microwave frequency for glucose‐enzyme reaction. Glucose interaction with glucose oxidase (GOD) produced gluconic acid and hydrogen peroxide. The reaction of the glucose solutions with an enzyme was carried out in 1:3 of glucose and enzyme respectively. The measurements were done using the Open Ended Coaxial Probe (OECP) coupled with computer controlled software automated network analyzer (ANA) with frequency range from 200MHz to 20GHz at room temperature (25 °C). The differences of enzyme and glucose‐enzyme reaction were calculated and plotted. In the microwave interaction with the glucose‐enzyme reaction, ionic conduction and dipole molecules was detected at 0.99GHz and 16.44GHz respectively based on changes of dielectric loss factor. |
format |
Conference or Workshop Item |
author |
Md Salim, Nora Salina Khalid, Kaida Yusof, Nor Azah |
spellingShingle |
Md Salim, Nora Salina Khalid, Kaida Yusof, Nor Azah Microwave‐based biosensor for glucose detection |
author_facet |
Md Salim, Nora Salina Khalid, Kaida Yusof, Nor Azah |
author_sort |
Md Salim, Nora Salina |
title |
Microwave‐based biosensor for glucose detection |
title_short |
Microwave‐based biosensor for glucose detection |
title_full |
Microwave‐based biosensor for glucose detection |
title_fullStr |
Microwave‐based biosensor for glucose detection |
title_full_unstemmed |
Microwave‐based biosensor for glucose detection |
title_sort |
microwave‐based biosensor for glucose detection |
publisher |
American Institute of Physics |
publishDate |
2009 |
url |
http://psasir.upm.edu.my/id/eprint/57283/1/Microwave%E2%80%90based%20biosensor%20for%20glucose%20detection.pdf http://psasir.upm.edu.my/id/eprint/57283/ |
_version_ |
1643836441332023296 |