A modified diametrical compression test technique (MDCTT) for mode II fracture toughness of iron powder compact
A sound knowledge of the fracture properties of a powder metallurgy (PM) component is essential for a design engineer to predict or prevent sudden fracture failure. Though iron powder is the most used base material in the PM industries, only its tensile mode fracture toughness (KIC) has been documen...
Saved in:
Main Authors: | , , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Elsevier
2017
|
Online Access: | http://psasir.upm.edu.my/id/eprint/60670/1/A%20modified%20diametrical%20compression%20test%20technique%20%28MDCTT%29%20for%20mode%20II%20fracture%20toughness%20of%20iron%20powder%20compact.pdf http://psasir.upm.edu.my/id/eprint/60670/ |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Institution: | Universiti Putra Malaysia |
Language: | English |
id |
my.upm.eprints.60670 |
---|---|
record_format |
eprints |
spelling |
my.upm.eprints.606702018-05-17T08:24:05Z http://psasir.upm.edu.my/id/eprint/60670/ A modified diametrical compression test technique (MDCTT) for mode II fracture toughness of iron powder compact Alabi, A. A. Mohd Tahir, Suraya Zahari, Nur Ismarrubie Mohamed Ariff, Azmah Hanim Anuar, Mohd Shamsul A sound knowledge of the fracture properties of a powder metallurgy (PM) component is essential for a design engineer to predict or prevent sudden fracture failure. Though iron powder is the most used base material in the PM industries, only its tensile mode fracture toughness (KIC) has been documented. This lack of adequate data can be traced to the non-availability of suitable test technique. In this paper, we present a new test approach for determining the mode II (shear mode) fracture toughness (KIIC) of iron powder compact. This method is known as the modified diametrical compression test technique (MDCTT). The MDCTT combined the qualities of diametrical compression test specimen with the pure shear mode failure of a riveted lap joint. The fracture toughness of copper powder compacts was also studied to corroborate the results of this technique. A comparison of the ratios for both powder compacts with theoretical predictions made using the maximum tangential stress criterion show strong agreement. Hence, the MDCTT is a suitable technique for determination of the KIIC values for iron and other metallic powder compacts. Elsevier 2017-09 Article PeerReviewed text en http://psasir.upm.edu.my/id/eprint/60670/1/A%20modified%20diametrical%20compression%20test%20technique%20%28MDCTT%29%20for%20mode%20II%20fracture%20toughness%20of%20iron%20powder%20compact.pdf Alabi, A. A. and Mohd Tahir, Suraya and Zahari, Nur Ismarrubie and Mohamed Ariff, Azmah Hanim and Anuar, Mohd Shamsul (2017) A modified diametrical compression test technique (MDCTT) for mode II fracture toughness of iron powder compact. Powder Technology, 319. pp. 356-364. ISSN 0032-5910; ESSN: 1873-328X 10.1016/j.powtec.2017.06.058 |
institution |
Universiti Putra Malaysia |
building |
UPM Library |
collection |
Institutional Repository |
continent |
Asia |
country |
Malaysia |
content_provider |
Universiti Putra Malaysia |
content_source |
UPM Institutional Repository |
url_provider |
http://psasir.upm.edu.my/ |
language |
English |
description |
A sound knowledge of the fracture properties of a powder metallurgy (PM) component is essential for a design engineer to predict or prevent sudden fracture failure. Though iron powder is the most used base material in the PM industries, only its tensile mode fracture toughness (KIC) has been documented. This lack of adequate data can be traced to the non-availability of suitable test technique. In this paper, we present a new test approach for determining the mode II (shear mode) fracture toughness (KIIC) of iron powder compact. This method is known as the modified diametrical compression test technique (MDCTT). The MDCTT combined the qualities of diametrical compression test specimen with the pure shear mode failure of a riveted lap joint. The fracture toughness of copper powder compacts was also studied to corroborate the results of this technique. A comparison of the ratios for both powder compacts with theoretical predictions made using the maximum tangential stress criterion show strong agreement. Hence, the MDCTT is a suitable technique for determination of the KIIC values for iron and other metallic powder compacts. |
format |
Article |
author |
Alabi, A. A. Mohd Tahir, Suraya Zahari, Nur Ismarrubie Mohamed Ariff, Azmah Hanim Anuar, Mohd Shamsul |
spellingShingle |
Alabi, A. A. Mohd Tahir, Suraya Zahari, Nur Ismarrubie Mohamed Ariff, Azmah Hanim Anuar, Mohd Shamsul A modified diametrical compression test technique (MDCTT) for mode II fracture toughness of iron powder compact |
author_facet |
Alabi, A. A. Mohd Tahir, Suraya Zahari, Nur Ismarrubie Mohamed Ariff, Azmah Hanim Anuar, Mohd Shamsul |
author_sort |
Alabi, A. A. |
title |
A modified diametrical compression test technique (MDCTT) for mode II fracture toughness of iron powder compact |
title_short |
A modified diametrical compression test technique (MDCTT) for mode II fracture toughness of iron powder compact |
title_full |
A modified diametrical compression test technique (MDCTT) for mode II fracture toughness of iron powder compact |
title_fullStr |
A modified diametrical compression test technique (MDCTT) for mode II fracture toughness of iron powder compact |
title_full_unstemmed |
A modified diametrical compression test technique (MDCTT) for mode II fracture toughness of iron powder compact |
title_sort |
modified diametrical compression test technique (mdctt) for mode ii fracture toughness of iron powder compact |
publisher |
Elsevier |
publishDate |
2017 |
url |
http://psasir.upm.edu.my/id/eprint/60670/1/A%20modified%20diametrical%20compression%20test%20technique%20%28MDCTT%29%20for%20mode%20II%20fracture%20toughness%20of%20iron%20powder%20compact.pdf http://psasir.upm.edu.my/id/eprint/60670/ |
_version_ |
1643837414539526144 |