Application of BATMAN and BAYESIL for quantitative ¹H-NMR based metabolomics of urine: discriminant analysis of lean, obese, and obese-diabetic rats

Introduction: BATMAN and BAYESIL are software tools, which can provide a solution for automated metabolite quantifications based on the proton nuclear magnetic resonance (1H-NMR) spectral data of bio-fluids. However, their specific application for the quantitative 1H-NMR based metabolomics of urine...

Full description

Saved in:
Bibliographic Details
Main Authors: Maulidiani, Rudiyanto, Mediani, Ahmed, Khatib, Alfi, Ismail, Amin, Hamid, Muhajir, H. Lajis, Nordin, Shaari, Khozirah, Abas, Faridah
Format: Article
Language:English
Published: OMICS International 2017
Online Access:http://psasir.upm.edu.my/id/eprint/60906/1/Application%20of%20BATMAN%20and%20BAYESIL%20for%20quantitative%20%C2%B9H-NMR%20based%20metabolomics%20of%20urine%20discriminant%20analysis%20of%20lean%2C%20obese%2C%20and%20obese-diabetic%20rats.pdf
http://psasir.upm.edu.my/id/eprint/60906/
https://link.springer.com/content/pdf/10.1007%2Fs11306-017-1273-0.pdf
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Universiti Putra Malaysia
Language: English
id my.upm.eprints.60906
record_format eprints
spelling my.upm.eprints.609062019-03-25T08:10:58Z http://psasir.upm.edu.my/id/eprint/60906/ Application of BATMAN and BAYESIL for quantitative ¹H-NMR based metabolomics of urine: discriminant analysis of lean, obese, and obese-diabetic rats Maulidiani Rudiyanto Mediani, Ahmed Khatib, Alfi Ismail, Amin Hamid, Muhajir H. Lajis, Nordin Shaari, Khozirah Abas, Faridah Introduction: BATMAN and BAYESIL are software tools, which can provide a solution for automated metabolite quantifications based on the proton nuclear magnetic resonance (1H-NMR) spectral data of bio-fluids. However, their specific application for the quantitative 1H-NMR based metabolomics of urine has not been investigated. Objectives: The aim of this study is to evaluate the performance of BATMAN and BAYESIL in the quantitative metabolite analysis of urine based on its 1H-NMR spectra. Methods: BATMAN and BAYESIL were used for automated metabolite quantification based on the 1H-NMR spectra of the urine from the lean, obese and obese-diabetic rat groups. PLS-DA model was used to discriminate the three different groups based on the results from the quantifications. Results:BATMAN was found to be superior to BAYESIL in identifying and quantifying the metabolites in the urine samples, owing to its flexibility that allows users to define and adjust the relevant signals of the pure standard metabolites in the database in order to fit the signals in the samples, a necessary step since variations and peak shift are natural in most 1H-NMR spectra. The results of BATMAN also agreed well with that of the manual deconvolution method, which indicated the higher accuracy in metabolite quantification, despite the need of pre-processing and longer processing time than BAYESIL. However, in the case where the problems in baseline correction and peak shift of 1H-NMR spectra are absent, the use of BAYESIL is more advantageous. Application of quantitative 1H-NMR based metabolomics of the urine showed that PLS-DA model derived from BATMAN could satisfactorily discriminate the lean, obese, and obese-diabetic rat groups. Conclusion: Both BATMAN and BAYESIL are useful for the quantitative automation of urine metabolites based on its 1H-NMR spectra. The results from BATMAN method is superior to BAYESIL but require expertise in spectroscopy and longer computer time. Both methods help in simplifying the interpretation of metabolite status in the VIP analysis. OMICS International 2017 Article PeerReviewed text en http://psasir.upm.edu.my/id/eprint/60906/1/Application%20of%20BATMAN%20and%20BAYESIL%20for%20quantitative%20%C2%B9H-NMR%20based%20metabolomics%20of%20urine%20discriminant%20analysis%20of%20lean%2C%20obese%2C%20and%20obese-diabetic%20rats.pdf Maulidiani and Rudiyanto and Mediani, Ahmed and Khatib, Alfi and Ismail, Amin and Hamid, Muhajir and H. Lajis, Nordin and Shaari, Khozirah and Abas, Faridah (2017) Application of BATMAN and BAYESIL for quantitative ¹H-NMR based metabolomics of urine: discriminant analysis of lean, obese, and obese-diabetic rats. Metabolomics, 13 (131). pp. 1-14. ISSN 2153-0769 https://link.springer.com/content/pdf/10.1007%2Fs11306-017-1273-0.pdf 10.1007/s11306-017-1273-0
institution Universiti Putra Malaysia
building UPM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Putra Malaysia
content_source UPM Institutional Repository
url_provider http://psasir.upm.edu.my/
language English
description Introduction: BATMAN and BAYESIL are software tools, which can provide a solution for automated metabolite quantifications based on the proton nuclear magnetic resonance (1H-NMR) spectral data of bio-fluids. However, their specific application for the quantitative 1H-NMR based metabolomics of urine has not been investigated. Objectives: The aim of this study is to evaluate the performance of BATMAN and BAYESIL in the quantitative metabolite analysis of urine based on its 1H-NMR spectra. Methods: BATMAN and BAYESIL were used for automated metabolite quantification based on the 1H-NMR spectra of the urine from the lean, obese and obese-diabetic rat groups. PLS-DA model was used to discriminate the three different groups based on the results from the quantifications. Results:BATMAN was found to be superior to BAYESIL in identifying and quantifying the metabolites in the urine samples, owing to its flexibility that allows users to define and adjust the relevant signals of the pure standard metabolites in the database in order to fit the signals in the samples, a necessary step since variations and peak shift are natural in most 1H-NMR spectra. The results of BATMAN also agreed well with that of the manual deconvolution method, which indicated the higher accuracy in metabolite quantification, despite the need of pre-processing and longer processing time than BAYESIL. However, in the case where the problems in baseline correction and peak shift of 1H-NMR spectra are absent, the use of BAYESIL is more advantageous. Application of quantitative 1H-NMR based metabolomics of the urine showed that PLS-DA model derived from BATMAN could satisfactorily discriminate the lean, obese, and obese-diabetic rat groups. Conclusion: Both BATMAN and BAYESIL are useful for the quantitative automation of urine metabolites based on its 1H-NMR spectra. The results from BATMAN method is superior to BAYESIL but require expertise in spectroscopy and longer computer time. Both methods help in simplifying the interpretation of metabolite status in the VIP analysis.
format Article
author Maulidiani
Rudiyanto
Mediani, Ahmed
Khatib, Alfi
Ismail, Amin
Hamid, Muhajir
H. Lajis, Nordin
Shaari, Khozirah
Abas, Faridah
spellingShingle Maulidiani
Rudiyanto
Mediani, Ahmed
Khatib, Alfi
Ismail, Amin
Hamid, Muhajir
H. Lajis, Nordin
Shaari, Khozirah
Abas, Faridah
Application of BATMAN and BAYESIL for quantitative ¹H-NMR based metabolomics of urine: discriminant analysis of lean, obese, and obese-diabetic rats
author_facet Maulidiani
Rudiyanto
Mediani, Ahmed
Khatib, Alfi
Ismail, Amin
Hamid, Muhajir
H. Lajis, Nordin
Shaari, Khozirah
Abas, Faridah
author_sort Maulidiani
title Application of BATMAN and BAYESIL for quantitative ¹H-NMR based metabolomics of urine: discriminant analysis of lean, obese, and obese-diabetic rats
title_short Application of BATMAN and BAYESIL for quantitative ¹H-NMR based metabolomics of urine: discriminant analysis of lean, obese, and obese-diabetic rats
title_full Application of BATMAN and BAYESIL for quantitative ¹H-NMR based metabolomics of urine: discriminant analysis of lean, obese, and obese-diabetic rats
title_fullStr Application of BATMAN and BAYESIL for quantitative ¹H-NMR based metabolomics of urine: discriminant analysis of lean, obese, and obese-diabetic rats
title_full_unstemmed Application of BATMAN and BAYESIL for quantitative ¹H-NMR based metabolomics of urine: discriminant analysis of lean, obese, and obese-diabetic rats
title_sort application of batman and bayesil for quantitative ¹h-nmr based metabolomics of urine: discriminant analysis of lean, obese, and obese-diabetic rats
publisher OMICS International
publishDate 2017
url http://psasir.upm.edu.my/id/eprint/60906/1/Application%20of%20BATMAN%20and%20BAYESIL%20for%20quantitative%20%C2%B9H-NMR%20based%20metabolomics%20of%20urine%20discriminant%20analysis%20of%20lean%2C%20obese%2C%20and%20obese-diabetic%20rats.pdf
http://psasir.upm.edu.my/id/eprint/60906/
https://link.springer.com/content/pdf/10.1007%2Fs11306-017-1273-0.pdf
_version_ 1643837462303211520