Investigation of severity of voltage flicker caused by second harmonic

Second harmonic produces asymmetrical waveform which leads to fluctuation of root-means-square (rms) value with certain frequency. Meanwhile, function of weighting filter in flickermeter is designed for sixth-order low-pass filtering function with frequency to be limited to 35 Hz, signal with freque...

Full description

Saved in:
Bibliographic Details
Main Authors: Goh, Zai Peng, Mohd Radzi, Mohd Amran, Hizam, Hashim, Abdul Wahab, Noor Izzri
Format: Article
Language:English
Published: The Institution of Engineering and Technology 2017
Online Access:http://psasir.upm.edu.my/id/eprint/62216/1/Investigation%20of%20severity%20of%20voltage%20flicker%20caused%20by%20second%20harmonic.pdf
http://psasir.upm.edu.my/id/eprint/62216/
https://ieeexplore.ieee.org/document/7929474
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Universiti Putra Malaysia
Language: English
id my.upm.eprints.62216
record_format eprints
spelling my.upm.eprints.622162019-04-22T08:58:59Z http://psasir.upm.edu.my/id/eprint/62216/ Investigation of severity of voltage flicker caused by second harmonic Goh, Zai Peng Mohd Radzi, Mohd Amran Hizam, Hashim Abdul Wahab, Noor Izzri Second harmonic produces asymmetrical waveform which leads to fluctuation of root-means-square (rms) value with certain frequency. Meanwhile, function of weighting filter in flickermeter is designed for sixth-order low-pass filtering function with frequency to be limited to 35 Hz, signal with frequency ranging from 35 to 100 Hz, at certain gain, still can pass through. Since the second harmonic produces fluctuation of rms value with 50 Hz, there is high possibility that it can be passed by this filter and thus resulting in flicker detection. Therefore, this study points out a worthwhile research gap to justify that the presence of the second harmonic can directly increase severity of voltage flicker. In addition, further simulation work using semi-converter has been carried out, as one of main even harmonic sources, in order to justify the concept. To practically validate the concept, Fluke power analyser 435 series II and programmable alternative current source are utilised in the experimental setup. In the main finding, it is confirmed that severity of the voltage flicker increases directly with the presence of the second harmonic and it also formed a clear relationship between short-term perceptibility (Pst) and percentage of the second harmonic component. The Institution of Engineering and Technology 2017-05 Article PeerReviewed text en http://psasir.upm.edu.my/id/eprint/62216/1/Investigation%20of%20severity%20of%20voltage%20flicker%20caused%20by%20second%20harmonic.pdf Goh, Zai Peng and Mohd Radzi, Mohd Amran and Hizam, Hashim and Abdul Wahab, Noor Izzri (2017) Investigation of severity of voltage flicker caused by second harmonic. IET Science Measurement & Technology, 11 (3). pp. 363-370. ISSN 1751-8822; ESSN: 1751-8830 https://ieeexplore.ieee.org/document/7929474 10.1049/iet-smt.2016.0369
institution Universiti Putra Malaysia
building UPM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Putra Malaysia
content_source UPM Institutional Repository
url_provider http://psasir.upm.edu.my/
language English
description Second harmonic produces asymmetrical waveform which leads to fluctuation of root-means-square (rms) value with certain frequency. Meanwhile, function of weighting filter in flickermeter is designed for sixth-order low-pass filtering function with frequency to be limited to 35 Hz, signal with frequency ranging from 35 to 100 Hz, at certain gain, still can pass through. Since the second harmonic produces fluctuation of rms value with 50 Hz, there is high possibility that it can be passed by this filter and thus resulting in flicker detection. Therefore, this study points out a worthwhile research gap to justify that the presence of the second harmonic can directly increase severity of voltage flicker. In addition, further simulation work using semi-converter has been carried out, as one of main even harmonic sources, in order to justify the concept. To practically validate the concept, Fluke power analyser 435 series II and programmable alternative current source are utilised in the experimental setup. In the main finding, it is confirmed that severity of the voltage flicker increases directly with the presence of the second harmonic and it also formed a clear relationship between short-term perceptibility (Pst) and percentage of the second harmonic component.
format Article
author Goh, Zai Peng
Mohd Radzi, Mohd Amran
Hizam, Hashim
Abdul Wahab, Noor Izzri
spellingShingle Goh, Zai Peng
Mohd Radzi, Mohd Amran
Hizam, Hashim
Abdul Wahab, Noor Izzri
Investigation of severity of voltage flicker caused by second harmonic
author_facet Goh, Zai Peng
Mohd Radzi, Mohd Amran
Hizam, Hashim
Abdul Wahab, Noor Izzri
author_sort Goh, Zai Peng
title Investigation of severity of voltage flicker caused by second harmonic
title_short Investigation of severity of voltage flicker caused by second harmonic
title_full Investigation of severity of voltage flicker caused by second harmonic
title_fullStr Investigation of severity of voltage flicker caused by second harmonic
title_full_unstemmed Investigation of severity of voltage flicker caused by second harmonic
title_sort investigation of severity of voltage flicker caused by second harmonic
publisher The Institution of Engineering and Technology
publishDate 2017
url http://psasir.upm.edu.my/id/eprint/62216/1/Investigation%20of%20severity%20of%20voltage%20flicker%20caused%20by%20second%20harmonic.pdf
http://psasir.upm.edu.my/id/eprint/62216/
https://ieeexplore.ieee.org/document/7929474
_version_ 1643837698071330816