S-band five-port ring reflectometer-probe system for in vitro breast tumor detection

A five-port ring reflectometer-probe system was developed to measure relative permittivity of normal and tumorous breast tissues in frequency range from 1.6 to 2.75 GHz. The calibration procedures of the study reflectometer and the coaxial probe were described in detail. In this study, the synthetic...

Full description

Saved in:
Bibliographic Details
Main Authors: Lee, Chia Yew, Kok, Yeow You, Abbas, Zulkifly, Lee, Kim Yee, Lee, Yeng Seng, Cheng, Ee Meng
Format: Article
Language:English
Published: Wiley 2018
Online Access:http://psasir.upm.edu.my/id/eprint/73829/1/BAND.pdf
http://psasir.upm.edu.my/id/eprint/73829/
https://onlinelibrary.wiley.com/doi/abs/10.1002/mmce.21198
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Universiti Putra Malaysia
Language: English
id my.upm.eprints.73829
record_format eprints
spelling my.upm.eprints.738292021-07-17T23:43:53Z http://psasir.upm.edu.my/id/eprint/73829/ S-band five-port ring reflectometer-probe system for in vitro breast tumor detection Lee, Chia Yew Kok, Yeow You Abbas, Zulkifly Lee, Kim Yee Lee, Yeng Seng Cheng, Ee Meng A five-port ring reflectometer-probe system was developed to measure relative permittivity of normal and tumorous breast tissues in frequency range from 1.6 to 2.75 GHz. The calibration procedures of the study reflectometer and the coaxial probe were described in detail. In this study, the synthetic breast tissues have been used, which are the Triton TX-100-water mixture at different ratios that mimic dielectric properties of normal and tumor breast tissue samples. The comparative studies of reflection coefficient and dielectric properties of the synthetic mixture samples were conducted using study reflectometer-probe system and commercial vector network analyzer with Keysight (formerly Agilent) 85070E dielectric probe. Maximum mean errors of the linear magnitude, phase, dielectric, and loss factor measurements were recorded to be 0.02, 6.1°, 2.21, and 1.60, respectively. These measurements were significantly distinguishable for normal and tumorous breast tissues. Wiley 2018-03 Article PeerReviewed text en http://psasir.upm.edu.my/id/eprint/73829/1/BAND.pdf Lee, Chia Yew and Kok, Yeow You and Abbas, Zulkifly and Lee, Kim Yee and Lee, Yeng Seng and Cheng, Ee Meng (2018) S-band five-port ring reflectometer-probe system for in vitro breast tumor detection. International Journal of RF and Microwave Computer-Aided Engineering, 28 (3). pp. 1-13. ISSN 1096-4290; ESSN: 1099-047X https://onlinelibrary.wiley.com/doi/abs/10.1002/mmce.21198 10.1002/mmce.21198
institution Universiti Putra Malaysia
building UPM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Putra Malaysia
content_source UPM Institutional Repository
url_provider http://psasir.upm.edu.my/
language English
description A five-port ring reflectometer-probe system was developed to measure relative permittivity of normal and tumorous breast tissues in frequency range from 1.6 to 2.75 GHz. The calibration procedures of the study reflectometer and the coaxial probe were described in detail. In this study, the synthetic breast tissues have been used, which are the Triton TX-100-water mixture at different ratios that mimic dielectric properties of normal and tumor breast tissue samples. The comparative studies of reflection coefficient and dielectric properties of the synthetic mixture samples were conducted using study reflectometer-probe system and commercial vector network analyzer with Keysight (formerly Agilent) 85070E dielectric probe. Maximum mean errors of the linear magnitude, phase, dielectric, and loss factor measurements were recorded to be 0.02, 6.1°, 2.21, and 1.60, respectively. These measurements were significantly distinguishable for normal and tumorous breast tissues.
format Article
author Lee, Chia Yew
Kok, Yeow You
Abbas, Zulkifly
Lee, Kim Yee
Lee, Yeng Seng
Cheng, Ee Meng
spellingShingle Lee, Chia Yew
Kok, Yeow You
Abbas, Zulkifly
Lee, Kim Yee
Lee, Yeng Seng
Cheng, Ee Meng
S-band five-port ring reflectometer-probe system for in vitro breast tumor detection
author_facet Lee, Chia Yew
Kok, Yeow You
Abbas, Zulkifly
Lee, Kim Yee
Lee, Yeng Seng
Cheng, Ee Meng
author_sort Lee, Chia Yew
title S-band five-port ring reflectometer-probe system for in vitro breast tumor detection
title_short S-band five-port ring reflectometer-probe system for in vitro breast tumor detection
title_full S-band five-port ring reflectometer-probe system for in vitro breast tumor detection
title_fullStr S-band five-port ring reflectometer-probe system for in vitro breast tumor detection
title_full_unstemmed S-band five-port ring reflectometer-probe system for in vitro breast tumor detection
title_sort s-band five-port ring reflectometer-probe system for in vitro breast tumor detection
publisher Wiley
publishDate 2018
url http://psasir.upm.edu.my/id/eprint/73829/1/BAND.pdf
http://psasir.upm.edu.my/id/eprint/73829/
https://onlinelibrary.wiley.com/doi/abs/10.1002/mmce.21198
_version_ 1706958785370652672