Direct and indirect entrance surface dose measurement in X-ray diagnostics using nanoDot OSL dosimeters

This study investigated the suitability of nanoDot optically stimulated luminescence (OSL) dosimeters for entrance surface dose (ESD) measurements in common X-ray diagnostics. OSL dosimetry system supplied by Landauer Inc, (Glenwood, IL, USA) consisting of nanoDot OSL dosimeters and microStar reader...

Full description

Saved in:
Bibliographic Details
Main Authors: Musa, Yahaya, Hashim, Suhairul, Abdul Karim, Muhammad Khalis
Format: Article
Language:English
Published: IOP Publishing 2019
Online Access:http://psasir.upm.edu.my/id/eprint/79392/1/Direct%20and%20indirect%20entrance%20surface%20dose%20.pdf
http://psasir.upm.edu.my/id/eprint/79392/
https://iopscience.iop.org/article/10.1088/1742-6596/1248/1/012014
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Universiti Putra Malaysia
Language: English
id my.upm.eprints.79392
record_format eprints
spelling my.upm.eprints.793922021-03-30T23:24:01Z http://psasir.upm.edu.my/id/eprint/79392/ Direct and indirect entrance surface dose measurement in X-ray diagnostics using nanoDot OSL dosimeters Musa, Yahaya Hashim, Suhairul Abdul Karim, Muhammad Khalis This study investigated the suitability of nanoDot optically stimulated luminescence (OSL) dosimeters for entrance surface dose (ESD) measurements in common X-ray diagnostics. OSL dosimetry system supplied by Landauer Inc, (Glenwood, IL, USA) consisting of nanoDot OSL dosimeters and microStar reader were used. ESDs were measured with nanoDots placed on whole-body anthropomorphic phantom (for direct measurements) and in free air without backscatter material (for indirect measurements) in accordance with the IAEA Technical Report Series No. 457. Measurements were carried out in five X-ray projections including AP abdomen, AP chest, PA chest, AP thoracic spine and AP skull. The mean ESD for each projection was evaluated from multiple measurements with three different field sizes. Mean ESDs (direct measurements) for AP abdomen, AP chest, PA chest, AP thoracic spine and AP skull were 4.3 mGy, 0.7 mGy, 0.3 mGy, 6.8 mGy and 2.8 mGy respectively. While in the case of indirect measurements, the corresponding mean ESD values were 4.8 mGy, 0.7 mGy, 0.2 mGy, 7.2 mGy and 3.7 mGy respectively. The results were found to be within IAEA and European Commission (EC) diagnostic reference levels (DRLs) range. The percentage difference of the ESDs measured by direct and indirect methods in all projections were between 0 to 40%. It was affirmed that nanoDot OSL dosimeter is a good candidate for ESD measurement in common radiographic examinations, while taking into account the effect of energy dependence. IOP Publishing 2019 Article PeerReviewed text en http://psasir.upm.edu.my/id/eprint/79392/1/Direct%20and%20indirect%20entrance%20surface%20dose%20.pdf Musa, Yahaya and Hashim, Suhairul and Abdul Karim, Muhammad Khalis (2019) Direct and indirect entrance surface dose measurement in X-ray diagnostics using nanoDot OSL dosimeters. Journal of Physics: Conference Series, 1248 (1). pp. 1-7. ISSN 1742-6588; ESSN: 1742-6596 https://iopscience.iop.org/article/10.1088/1742-6596/1248/1/012014 10.1088/1742-6596/1248/1/012014
institution Universiti Putra Malaysia
building UPM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Putra Malaysia
content_source UPM Institutional Repository
url_provider http://psasir.upm.edu.my/
language English
description This study investigated the suitability of nanoDot optically stimulated luminescence (OSL) dosimeters for entrance surface dose (ESD) measurements in common X-ray diagnostics. OSL dosimetry system supplied by Landauer Inc, (Glenwood, IL, USA) consisting of nanoDot OSL dosimeters and microStar reader were used. ESDs were measured with nanoDots placed on whole-body anthropomorphic phantom (for direct measurements) and in free air without backscatter material (for indirect measurements) in accordance with the IAEA Technical Report Series No. 457. Measurements were carried out in five X-ray projections including AP abdomen, AP chest, PA chest, AP thoracic spine and AP skull. The mean ESD for each projection was evaluated from multiple measurements with three different field sizes. Mean ESDs (direct measurements) for AP abdomen, AP chest, PA chest, AP thoracic spine and AP skull were 4.3 mGy, 0.7 mGy, 0.3 mGy, 6.8 mGy and 2.8 mGy respectively. While in the case of indirect measurements, the corresponding mean ESD values were 4.8 mGy, 0.7 mGy, 0.2 mGy, 7.2 mGy and 3.7 mGy respectively. The results were found to be within IAEA and European Commission (EC) diagnostic reference levels (DRLs) range. The percentage difference of the ESDs measured by direct and indirect methods in all projections were between 0 to 40%. It was affirmed that nanoDot OSL dosimeter is a good candidate for ESD measurement in common radiographic examinations, while taking into account the effect of energy dependence.
format Article
author Musa, Yahaya
Hashim, Suhairul
Abdul Karim, Muhammad Khalis
spellingShingle Musa, Yahaya
Hashim, Suhairul
Abdul Karim, Muhammad Khalis
Direct and indirect entrance surface dose measurement in X-ray diagnostics using nanoDot OSL dosimeters
author_facet Musa, Yahaya
Hashim, Suhairul
Abdul Karim, Muhammad Khalis
author_sort Musa, Yahaya
title Direct and indirect entrance surface dose measurement in X-ray diagnostics using nanoDot OSL dosimeters
title_short Direct and indirect entrance surface dose measurement in X-ray diagnostics using nanoDot OSL dosimeters
title_full Direct and indirect entrance surface dose measurement in X-ray diagnostics using nanoDot OSL dosimeters
title_fullStr Direct and indirect entrance surface dose measurement in X-ray diagnostics using nanoDot OSL dosimeters
title_full_unstemmed Direct and indirect entrance surface dose measurement in X-ray diagnostics using nanoDot OSL dosimeters
title_sort direct and indirect entrance surface dose measurement in x-ray diagnostics using nanodot osl dosimeters
publisher IOP Publishing
publishDate 2019
url http://psasir.upm.edu.my/id/eprint/79392/1/Direct%20and%20indirect%20entrance%20surface%20dose%20.pdf
http://psasir.upm.edu.my/id/eprint/79392/
https://iopscience.iop.org/article/10.1088/1742-6596/1248/1/012014
_version_ 1696977666992766976