Occupant interaction with window blinds in a green-certified office building in Putrajaya, Malaysia

One of the key features of green office buildings is the proper utilization of daylight in order to ensure a good visual indoor environment which can potentially increase the occupant's productivity. However, poor daylight condition inside office buildings can occur due to improper positioning...

Full description

Saved in:
Bibliographic Details
Main Authors: Jubaer Alam, S. M., Shari, Zalina
Format: Article
Language:English
Published: University of Malaya 2019
Online Access:http://psasir.upm.edu.my/id/eprint/81519/1/Occupant%20interaction%20with%20window%20blinds%20in%20a%20green-certified%20office%20building%20in%20Putrajaya%2C%20Malaysia.pdf
http://psasir.upm.edu.my/id/eprint/81519/
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Universiti Putra Malaysia
Language: English
id my.upm.eprints.81519
record_format eprints
spelling my.upm.eprints.815192020-10-30T08:55:15Z http://psasir.upm.edu.my/id/eprint/81519/ Occupant interaction with window blinds in a green-certified office building in Putrajaya, Malaysia Jubaer Alam, S. M. Shari, Zalina One of the key features of green office buildings is the proper utilization of daylight in order to ensure a good visual indoor environment which can potentially increase the occupant's productivity. However, poor daylight condition inside office buildings can occur due to improper positioning of window blinds by the occupants. Previous studies have shown that fully lowered window blinds and the use of the artificial lightings during daytime have caused many office buildings in Malaysia to have high rates of electricity consumption. Yet, the operation of window blinds is rarely considered during the calculation of building's daylight performance in the tropics. Therefore, this paper aims to investigate the frequency of window blind operations by office occupants and the driving factors behind their window blind operations. A GBI Gold-certified office building was selected for the study. The specific objectives of this paper are, 1) to find out the correlation between window blind operations with different orientations of the building, sky conditions, time and floor levels; and 2) to gauge the occupants' views on their window blind operations and also their satisfaction level with their visual working environment. This study used time-lapse photography to record the blinds positions and a questionnaire survey among the occupants. Results of the ANOVA and Pearson Correlation tests from the photographic analysis found a strong correlation between window blind occlusion values with the building orientations and floor levels, but not with time. The survey results revealed that most of the participants seldom adjusted their window blinds and, in most cases, excessive brightness or glare was the main issue. These results indicate that the occupants make a little effort in changing their blind positions, which may lead to a poor daylight condition. It is expected that the results of this study will serve as the initial steps in considering occupants' behaviour in window blinds usage during the calculation process of a building's daylight performance in order to ensure a better indoor visual environment. University of Malaya 2019 Article PeerReviewed text en http://psasir.upm.edu.my/id/eprint/81519/1/Occupant%20interaction%20with%20window%20blinds%20in%20a%20green-certified%20office%20building%20in%20Putrajaya%2C%20Malaysia.pdf Jubaer Alam, S. M. and Shari, Zalina (2019) Occupant interaction with window blinds in a green-certified office building in Putrajaya, Malaysia. Journal of Design and Built Environment, 19 (1). pp. 60-73. ISSN 2232-1500; ESSN: 1823-4208
institution Universiti Putra Malaysia
building UPM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Putra Malaysia
content_source UPM Institutional Repository
url_provider http://psasir.upm.edu.my/
language English
description One of the key features of green office buildings is the proper utilization of daylight in order to ensure a good visual indoor environment which can potentially increase the occupant's productivity. However, poor daylight condition inside office buildings can occur due to improper positioning of window blinds by the occupants. Previous studies have shown that fully lowered window blinds and the use of the artificial lightings during daytime have caused many office buildings in Malaysia to have high rates of electricity consumption. Yet, the operation of window blinds is rarely considered during the calculation of building's daylight performance in the tropics. Therefore, this paper aims to investigate the frequency of window blind operations by office occupants and the driving factors behind their window blind operations. A GBI Gold-certified office building was selected for the study. The specific objectives of this paper are, 1) to find out the correlation between window blind operations with different orientations of the building, sky conditions, time and floor levels; and 2) to gauge the occupants' views on their window blind operations and also their satisfaction level with their visual working environment. This study used time-lapse photography to record the blinds positions and a questionnaire survey among the occupants. Results of the ANOVA and Pearson Correlation tests from the photographic analysis found a strong correlation between window blind occlusion values with the building orientations and floor levels, but not with time. The survey results revealed that most of the participants seldom adjusted their window blinds and, in most cases, excessive brightness or glare was the main issue. These results indicate that the occupants make a little effort in changing their blind positions, which may lead to a poor daylight condition. It is expected that the results of this study will serve as the initial steps in considering occupants' behaviour in window blinds usage during the calculation process of a building's daylight performance in order to ensure a better indoor visual environment.
format Article
author Jubaer Alam, S. M.
Shari, Zalina
spellingShingle Jubaer Alam, S. M.
Shari, Zalina
Occupant interaction with window blinds in a green-certified office building in Putrajaya, Malaysia
author_facet Jubaer Alam, S. M.
Shari, Zalina
author_sort Jubaer Alam, S. M.
title Occupant interaction with window blinds in a green-certified office building in Putrajaya, Malaysia
title_short Occupant interaction with window blinds in a green-certified office building in Putrajaya, Malaysia
title_full Occupant interaction with window blinds in a green-certified office building in Putrajaya, Malaysia
title_fullStr Occupant interaction with window blinds in a green-certified office building in Putrajaya, Malaysia
title_full_unstemmed Occupant interaction with window blinds in a green-certified office building in Putrajaya, Malaysia
title_sort occupant interaction with window blinds in a green-certified office building in putrajaya, malaysia
publisher University of Malaya
publishDate 2019
url http://psasir.upm.edu.my/id/eprint/81519/1/Occupant%20interaction%20with%20window%20blinds%20in%20a%20green-certified%20office%20building%20in%20Putrajaya%2C%20Malaysia.pdf
http://psasir.upm.edu.my/id/eprint/81519/
_version_ 1682298728023588864