Effect of single and double stenosed on renal arteries of abdominal aorta: a computational fluid dynamics
This study investigated the impact of single stenosed (SS) and double stenosed (DS) of renal artery branches using the Computational Fluid Dynamics (CFD) approach. A 3D abdominal aorta with renal artery branches model was constructed using MIMICS software. Some modification of SS and DS are applied...
Saved in:
Main Authors: | , , , , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Penerbit Akademia Baru
2020
|
Online Access: | http://psasir.upm.edu.my/id/eprint/88638/1/ABSTRACT.pdf http://psasir.upm.edu.my/id/eprint/88638/ https://www.akademiabaru.com/submit/index.php/cfdl/article/view/3132 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Institution: | Universiti Putra Malaysia |
Language: | English |
id |
my.upm.eprints.88638 |
---|---|
record_format |
eprints |
spelling |
my.upm.eprints.886382021-11-03T07:05:51Z http://psasir.upm.edu.my/id/eprint/88638/ Effect of single and double stenosed on renal arteries of abdominal aorta: a computational fluid dynamics Basri, Adi Azriff Abdul Khader, Shah Mohammed Johny, Cherian Pai B, Raghuvir Zuber, Mohammad Ahmad, Zainuldin Ahmad, Kamarul Arifin This study investigated the impact of single stenosed (SS) and double stenosed (DS) of renal artery branches using the Computational Fluid Dynamics (CFD) approach. A 3D abdominal aorta with renal artery branches model was constructed using MIMICS software. Some modification of SS and DS are applied at right and left renal artery branches, respectively. Numerical analysis of both stenosed cases with the condition of normal blood pressure (NBP) and high blood pressure (HBP) are performed using CFD solver in software ANSYS-18. The results of velocity, pressure and wall shear stress of SS and DS renal artery branches with the condition of NBP and HBP are compared with respect to the blood flow behavior. The results concluded that DS-NBP showed the highest value for velocity magnitude. Meanwhile for pressure and wall shear stress value, DS-HBP showed the highest value for both results, respectively. The present study demonstrates the fundamental aspects of haemodynamics of blood flow behavior in idealized abdominal aorta with stenosed renal branches subjected to the normal and high pressure conditions of DS and SS cases of renal artery branches. Penerbit Akademia Baru 2020 Article PeerReviewed text en http://psasir.upm.edu.my/id/eprint/88638/1/ABSTRACT.pdf Basri, Adi Azriff and Abdul Khader, Shah Mohammed and Johny, Cherian and Pai B, Raghuvir and Zuber, Mohammad and Ahmad, Zainuldin and Ahmad, Kamarul Arifin (2020) Effect of single and double stenosed on renal arteries of abdominal aorta: a computational fluid dynamics. CFD Letters, 12 (1). 87 - 97. ISSN 2180-1363 https://www.akademiabaru.com/submit/index.php/cfdl/article/view/3132 |
institution |
Universiti Putra Malaysia |
building |
UPM Library |
collection |
Institutional Repository |
continent |
Asia |
country |
Malaysia |
content_provider |
Universiti Putra Malaysia |
content_source |
UPM Institutional Repository |
url_provider |
http://psasir.upm.edu.my/ |
language |
English |
description |
This study investigated the impact of single stenosed (SS) and double stenosed (DS) of renal artery branches using the Computational Fluid Dynamics (CFD) approach. A 3D abdominal aorta with renal artery branches model was constructed using MIMICS software. Some modification of SS and DS are applied at right and left renal artery branches, respectively. Numerical analysis of both stenosed cases with the condition of normal blood pressure (NBP) and high blood pressure (HBP) are performed using CFD solver in software ANSYS-18. The results of velocity, pressure and wall shear stress of SS and DS renal artery branches with the condition of NBP and HBP are compared with respect to the blood flow behavior. The results concluded that DS-NBP showed the highest value for velocity magnitude. Meanwhile for pressure and wall shear stress value, DS-HBP showed the highest value for both results, respectively. The present study demonstrates the fundamental aspects of haemodynamics of blood flow behavior in idealized abdominal aorta with stenosed renal branches subjected to the normal and high pressure conditions of DS and SS cases of renal artery branches. |
format |
Article |
author |
Basri, Adi Azriff Abdul Khader, Shah Mohammed Johny, Cherian Pai B, Raghuvir Zuber, Mohammad Ahmad, Zainuldin Ahmad, Kamarul Arifin |
spellingShingle |
Basri, Adi Azriff Abdul Khader, Shah Mohammed Johny, Cherian Pai B, Raghuvir Zuber, Mohammad Ahmad, Zainuldin Ahmad, Kamarul Arifin Effect of single and double stenosed on renal arteries of abdominal aorta: a computational fluid dynamics |
author_facet |
Basri, Adi Azriff Abdul Khader, Shah Mohammed Johny, Cherian Pai B, Raghuvir Zuber, Mohammad Ahmad, Zainuldin Ahmad, Kamarul Arifin |
author_sort |
Basri, Adi Azriff |
title |
Effect of single and double stenosed on renal arteries of abdominal aorta: a computational fluid dynamics |
title_short |
Effect of single and double stenosed on renal arteries of abdominal aorta: a computational fluid dynamics |
title_full |
Effect of single and double stenosed on renal arteries of abdominal aorta: a computational fluid dynamics |
title_fullStr |
Effect of single and double stenosed on renal arteries of abdominal aorta: a computational fluid dynamics |
title_full_unstemmed |
Effect of single and double stenosed on renal arteries of abdominal aorta: a computational fluid dynamics |
title_sort |
effect of single and double stenosed on renal arteries of abdominal aorta: a computational fluid dynamics |
publisher |
Penerbit Akademia Baru |
publishDate |
2020 |
url |
http://psasir.upm.edu.my/id/eprint/88638/1/ABSTRACT.pdf http://psasir.upm.edu.my/id/eprint/88638/ https://www.akademiabaru.com/submit/index.php/cfdl/article/view/3132 |
_version_ |
1717095400946532352 |