Hepatitis C Virus Genotyping Methods: Evaluation of AmpliSens (R) HCV-1/2/3-FRT Compared to Sequencing Method

Background Hepatitis C virus (HCV) genotyping is important for treatment and epidemiological purposes. The objective of this study was to evaluate the performance of AmpliSens (R) HCV-1/2/3-FRT kit in comparison to sequencing method for genotyping. Methods A total of 17 samples collected from Decemb...

Full description

Saved in:
Bibliographic Details
Main Authors: Nurul Azmawati, Mohamed, Zetti, Zainol Rashid, Kon Ken, Wong
Format: Article
Language:English
Published: John Wiley & Sons Inc 2015
Subjects:
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Universiti Sains Islam Malaysia
Language: English
id my.usim-8215
record_format dspace
spelling my.usim-82152017-02-20T04:44:17Z Hepatitis C Virus Genotyping Methods: Evaluation of AmpliSens (R) HCV-1/2/3-FRT Compared to Sequencing Method Nurul Azmawati, Mohamed, Zetti, Zainol Rashid, Kon Ken, Wong, HCV Genotype Sequencing Methods RT-PCR Real Time Amplisens (R) HCV-1/2/3-FRT HCV Subtype Background Hepatitis C virus (HCV) genotyping is important for treatment and epidemiological purposes. The objective of this study was to evaluate the performance of AmpliSens (R) HCV-1/2/3-FRT kit in comparison to sequencing method for genotyping. Methods A total of 17 samples collected from December 2009 to January 2011 were analyzed. Reverse transcriptase polymerase chain reaction (PCR) was performed, followed by sequencing technique. Results were analyzed based on sequence information in GenBank. A second genotyping method (AmpliSens (R) HCV-1/2/3-FRT) was done, which differentiates HCV genotypes by means of real-time hybridization-fluorescence detection. Results From 17 samples, four were untypeable by AmpliSens (R) HCV-1/2/3-FRT. Eleven of 13 (84.6%) results showed concordant genotypes. A specimen that was determined as genotype 3a by sequencing was genotype 1 by the AmpliSens (R) HCV-1/2/3-FRT. Another specimen that was genotype 1 by sequencing was identified as genotype 3 by AmpliSens (R) HCV-1/2/3-FRT. Conclusion HCV genotyping with AmpliSens (R) HCV-1/2/3-FRT using real-time PCR method provides a much simpler and more feasible workflow with shorter time compared to sequencing method. There was good concordance compared to sequencing method. However, more evaluation studies would be required to show statistical significance, and to troubleshoot discordant results. AmpliSens (R) HCV-1/2/3-FRT does differentiate between genotype but not until subtype level. 2015-05-19T02:32:16Z 2015-05-19T02:32:16Z 2014-01-01 Article 0887-8013 1098-2825 en John Wiley & Sons Inc
institution Universiti Sains Islam Malaysia
building USIM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universit Sains Islam i Malaysia
content_source USIM Institutional Repository
url_provider http://ddms.usim.edu.my/
language English
topic HCV Genotype
Sequencing Methods
RT-PCR
Real Time
Amplisens (R) HCV-1/2/3-FRT
HCV Subtype
spellingShingle HCV Genotype
Sequencing Methods
RT-PCR
Real Time
Amplisens (R) HCV-1/2/3-FRT
HCV Subtype
Nurul Azmawati, Mohamed,
Zetti, Zainol Rashid,
Kon Ken, Wong,
Hepatitis C Virus Genotyping Methods: Evaluation of AmpliSens (R) HCV-1/2/3-FRT Compared to Sequencing Method
description Background Hepatitis C virus (HCV) genotyping is important for treatment and epidemiological purposes. The objective of this study was to evaluate the performance of AmpliSens (R) HCV-1/2/3-FRT kit in comparison to sequencing method for genotyping. Methods A total of 17 samples collected from December 2009 to January 2011 were analyzed. Reverse transcriptase polymerase chain reaction (PCR) was performed, followed by sequencing technique. Results were analyzed based on sequence information in GenBank. A second genotyping method (AmpliSens (R) HCV-1/2/3-FRT) was done, which differentiates HCV genotypes by means of real-time hybridization-fluorescence detection. Results From 17 samples, four were untypeable by AmpliSens (R) HCV-1/2/3-FRT. Eleven of 13 (84.6%) results showed concordant genotypes. A specimen that was determined as genotype 3a by sequencing was genotype 1 by the AmpliSens (R) HCV-1/2/3-FRT. Another specimen that was genotype 1 by sequencing was identified as genotype 3 by AmpliSens (R) HCV-1/2/3-FRT. Conclusion HCV genotyping with AmpliSens (R) HCV-1/2/3-FRT using real-time PCR method provides a much simpler and more feasible workflow with shorter time compared to sequencing method. There was good concordance compared to sequencing method. However, more evaluation studies would be required to show statistical significance, and to troubleshoot discordant results. AmpliSens (R) HCV-1/2/3-FRT does differentiate between genotype but not until subtype level.
format Article
author Nurul Azmawati, Mohamed,
Zetti, Zainol Rashid,
Kon Ken, Wong,
author_facet Nurul Azmawati, Mohamed,
Zetti, Zainol Rashid,
Kon Ken, Wong,
author_sort Nurul Azmawati, Mohamed,
title Hepatitis C Virus Genotyping Methods: Evaluation of AmpliSens (R) HCV-1/2/3-FRT Compared to Sequencing Method
title_short Hepatitis C Virus Genotyping Methods: Evaluation of AmpliSens (R) HCV-1/2/3-FRT Compared to Sequencing Method
title_full Hepatitis C Virus Genotyping Methods: Evaluation of AmpliSens (R) HCV-1/2/3-FRT Compared to Sequencing Method
title_fullStr Hepatitis C Virus Genotyping Methods: Evaluation of AmpliSens (R) HCV-1/2/3-FRT Compared to Sequencing Method
title_full_unstemmed Hepatitis C Virus Genotyping Methods: Evaluation of AmpliSens (R) HCV-1/2/3-FRT Compared to Sequencing Method
title_sort hepatitis c virus genotyping methods: evaluation of amplisens (r) hcv-1/2/3-frt compared to sequencing method
publisher John Wiley & Sons Inc
publishDate 2015
_version_ 1645152366840774656