Highly Sensitive Fluorescence Optode Based on Polymer Inclusion Membranes for Determination of Al(III) Ions

This paper reports the use of a polymer inclusion membranes (PIMs) for direct determination of Al(III) ions in natural water by using a fluorescence based optode. The best composition of the PIMs consisted of 60 wt.% (m/m) poly (vinyl chloride) (PVC) as the base polymer, 20 wt.% (m/m) triton X-100 a...

Full description

Saved in:
Bibliographic Details
Main Authors: F. B. M., Suah, L. Y., Heng, M., Ahmad
Format: Article
Language:English
Published: Springer/Plenum Publishers 2015
Subjects:
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Universiti Sains Islam Malaysia
Language: English
id my.usim-8217
record_format dspace
spelling my.usim-82172017-02-20T04:53:50Z Highly Sensitive Fluorescence Optode Based on Polymer Inclusion Membranes for Determination of Al(III) Ions F. B. M., Suah, L. Y., Heng, M., Ahmad, Aluminium(III) determination Optode Natural waters Polymer inclusion membrane This paper reports the use of a polymer inclusion membranes (PIMs) for direct determination of Al(III) ions in natural water by using a fluorescence based optode. The best composition of the PIMs consisted of 60 wt.% (m/m) poly (vinyl chloride) (PVC) as the base polymer, 20 wt.% (m/m) triton X-100 as an extractant, 20 wt.% (m/m) dioctyl phthalate (DOP) as plasticizer and morin as the reagent, was used in this study. The inclusion of triton X-100 was used for enhancing the sorption of Al(III) ions from liquid phase into the membrane phase, thus increasing the optode fluorescence intensity. The optimized optode was characterized by a linear calibration curve in the range from 7.41 x 10(-7) to 1.00 x 10(-4) molL(-1) of Al(III), with a detection limit of 5.19 x 10(-7) molL(-1). The response of the optode was 4 min and reproducible results were obtained for eight different membranes demonstrated good membrane stability. The optode was applied to the determination of Al(III) in natural water samples. The result obtained is comparable to atomic absorption spectrometry method. 2015-05-19T02:38:45Z 2015-05-19T02:38:45Z 2014-01-01 Article 1053-0509 1573-4994 en Springer/Plenum Publishers
institution Universiti Sains Islam Malaysia
building USIM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universit Sains Islam i Malaysia
content_source USIM Institutional Repository
url_provider http://ddms.usim.edu.my/
language English
topic Aluminium(III) determination
Optode
Natural waters
Polymer inclusion membrane
spellingShingle Aluminium(III) determination
Optode
Natural waters
Polymer inclusion membrane
F. B. M., Suah,
L. Y., Heng,
M., Ahmad,
Highly Sensitive Fluorescence Optode Based on Polymer Inclusion Membranes for Determination of Al(III) Ions
description This paper reports the use of a polymer inclusion membranes (PIMs) for direct determination of Al(III) ions in natural water by using a fluorescence based optode. The best composition of the PIMs consisted of 60 wt.% (m/m) poly (vinyl chloride) (PVC) as the base polymer, 20 wt.% (m/m) triton X-100 as an extractant, 20 wt.% (m/m) dioctyl phthalate (DOP) as plasticizer and morin as the reagent, was used in this study. The inclusion of triton X-100 was used for enhancing the sorption of Al(III) ions from liquid phase into the membrane phase, thus increasing the optode fluorescence intensity. The optimized optode was characterized by a linear calibration curve in the range from 7.41 x 10(-7) to 1.00 x 10(-4) molL(-1) of Al(III), with a detection limit of 5.19 x 10(-7) molL(-1). The response of the optode was 4 min and reproducible results were obtained for eight different membranes demonstrated good membrane stability. The optode was applied to the determination of Al(III) in natural water samples. The result obtained is comparable to atomic absorption spectrometry method.
format Article
author F. B. M., Suah,
L. Y., Heng,
M., Ahmad,
author_facet F. B. M., Suah,
L. Y., Heng,
M., Ahmad,
author_sort F. B. M., Suah,
title Highly Sensitive Fluorescence Optode Based on Polymer Inclusion Membranes for Determination of Al(III) Ions
title_short Highly Sensitive Fluorescence Optode Based on Polymer Inclusion Membranes for Determination of Al(III) Ions
title_full Highly Sensitive Fluorescence Optode Based on Polymer Inclusion Membranes for Determination of Al(III) Ions
title_fullStr Highly Sensitive Fluorescence Optode Based on Polymer Inclusion Membranes for Determination of Al(III) Ions
title_full_unstemmed Highly Sensitive Fluorescence Optode Based on Polymer Inclusion Membranes for Determination of Al(III) Ions
title_sort highly sensitive fluorescence optode based on polymer inclusion membranes for determination of al(iii) ions
publisher Springer/Plenum Publishers
publishDate 2015
_version_ 1645152367133327360