Development Of Wireless Sensor Network For Monitoring Indoor Air Quality

It is an undeniable fact that air quality is vital in our daily lives. The contributing indoor air pollution at the workplace or in our residential areas has caught the attention of scientists and generally, the public in recent years. It is interesting to find that the studies done came up with...

Full description

Saved in:
Bibliographic Details
Main Author: Idris, Mohaiyedin
Format: Thesis
Language:English
Published: 2010
Subjects:
Online Access:http://eprints.usm.my/41658/1/MOHAIYEDIN_IDRIS_HJ.pdf
http://eprints.usm.my/41658/
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Universiti Sains Malaysia
Language: English
id my.usm.eprints.41658
record_format eprints
spelling my.usm.eprints.41658 http://eprints.usm.my/41658/ Development Of Wireless Sensor Network For Monitoring Indoor Air Quality Idris, Mohaiyedin TK Electrical Engineering. Electronics. Nuclear Engineering It is an undeniable fact that air quality is vital in our daily lives. The contributing indoor air pollution at the workplace or in our residential areas has caught the attention of scientists and generally, the public in recent years. It is interesting to find that the studies done came up with the discovery that the indoor air pollution contributes higher degree of air contaminants compared to the level of air pollution outdoor. This is probably explained by the fact that people tend to spend 90 % of their time indoor and the rest on outdoor activities. Unpolluted air furnishes us with good, comfortable, and healthy lifestyles which may lead to a productive working environment and at the same time, contribute to a better peace of mind. The approach of wireless sensor network is applied in order to detect and monitor the indoor air pollution. The air quality parameters such as air temperature, percentage of relative humidity, and air contaminants are carried out in this research. LM35DZ temperature sensor and A0545 humidity sensor are employed to measure air temperature and relative humidity in percentage. Based on these two measurements, dew point is obtained to measure the level of air temperature required to produce 100 % relative humidity. The TGS2600 semiconductor gas sensor is employed to detect air contaminants of carbon monoxide with 0.0188 mean square error. In this research, six nodes and a data handler are developed. Each sensor node consists of PIC16F877 microcontroller device with three sensors (temperature, humidity and gas sensors) and SRWF-508 transceiver module. All the sensor nodes are connected to the data handler through the star network to monitor air quality. 2010-10 Thesis NonPeerReviewed application/pdf en http://eprints.usm.my/41658/1/MOHAIYEDIN_IDRIS_HJ.pdf Idris, Mohaiyedin (2010) Development Of Wireless Sensor Network For Monitoring Indoor Air Quality. Masters thesis, Universiti Sains Malaysia.
institution Universiti Sains Malaysia
building Hamzah Sendut Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Sains Malaysia
content_source USM Institutional Repository
url_provider http://eprints.usm.my/
language English
topic TK Electrical Engineering. Electronics. Nuclear Engineering
spellingShingle TK Electrical Engineering. Electronics. Nuclear Engineering
Idris, Mohaiyedin
Development Of Wireless Sensor Network For Monitoring Indoor Air Quality
description It is an undeniable fact that air quality is vital in our daily lives. The contributing indoor air pollution at the workplace or in our residential areas has caught the attention of scientists and generally, the public in recent years. It is interesting to find that the studies done came up with the discovery that the indoor air pollution contributes higher degree of air contaminants compared to the level of air pollution outdoor. This is probably explained by the fact that people tend to spend 90 % of their time indoor and the rest on outdoor activities. Unpolluted air furnishes us with good, comfortable, and healthy lifestyles which may lead to a productive working environment and at the same time, contribute to a better peace of mind. The approach of wireless sensor network is applied in order to detect and monitor the indoor air pollution. The air quality parameters such as air temperature, percentage of relative humidity, and air contaminants are carried out in this research. LM35DZ temperature sensor and A0545 humidity sensor are employed to measure air temperature and relative humidity in percentage. Based on these two measurements, dew point is obtained to measure the level of air temperature required to produce 100 % relative humidity. The TGS2600 semiconductor gas sensor is employed to detect air contaminants of carbon monoxide with 0.0188 mean square error. In this research, six nodes and a data handler are developed. Each sensor node consists of PIC16F877 microcontroller device with three sensors (temperature, humidity and gas sensors) and SRWF-508 transceiver module. All the sensor nodes are connected to the data handler through the star network to monitor air quality.
format Thesis
author Idris, Mohaiyedin
author_facet Idris, Mohaiyedin
author_sort Idris, Mohaiyedin
title Development Of Wireless Sensor Network For Monitoring Indoor Air Quality
title_short Development Of Wireless Sensor Network For Monitoring Indoor Air Quality
title_full Development Of Wireless Sensor Network For Monitoring Indoor Air Quality
title_fullStr Development Of Wireless Sensor Network For Monitoring Indoor Air Quality
title_full_unstemmed Development Of Wireless Sensor Network For Monitoring Indoor Air Quality
title_sort development of wireless sensor network for monitoring indoor air quality
publishDate 2010
url http://eprints.usm.my/41658/1/MOHAIYEDIN_IDRIS_HJ.pdf
http://eprints.usm.my/41658/
_version_ 1643710282792435712