A five years review of complications of implantable venous access devices (IVAD) in cancer patient through the cephalic vein cut down approach

Introduction: Implanted venous access device (IVAD) is one of the options that give access to the central venous circulation. It is widely used nowadays and can be used for various reasons. It can be retained in the body for a period of up to two years with minimal care and low risk of infection...

Full description

Saved in:
Bibliographic Details
Main Author: Nor, Sobri
Format: Thesis
Language:English
Published: 2018
Subjects:
Online Access:http://eprints.usm.my/48550/1/Dr.%20Sobri%20Nor-24%20pages.pdf
http://eprints.usm.my/48550/
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Universiti Sains Malaysia
Language: English
id my.usm.eprints.48550
record_format eprints
spelling my.usm.eprints.48550 http://eprints.usm.my/48550/ A five years review of complications of implantable venous access devices (IVAD) in cancer patient through the cephalic vein cut down approach Nor, Sobri RC666-701 Diseases of the circulatory (Cardiovascular) system Introduction: Implanted venous access device (IVAD) is one of the options that give access to the central venous circulation. It is widely used nowadays and can be used for various reasons. It can be retained in the body for a period of up to two years with minimal care and low risk of infection thus it is suitable for patients especially for those who had the difficult vascular access example in cancer patients. Cephalic vein cut down approach is one of the methods of insertion of IVAD with minimal complication associated to this technique, however, it is not widely used as it needs to be done in operating theatre setting and it took longer duration. This study was done to evaluate the complication of the IVAD that implanted in cancer patient through cephalic vein cut down approach. Methodology: This is a retrospective study involving cancer patients that were implanted with IVAD through cephalic vein cut-down approach in HUSM from January 2010 to December 2014. All medical records reviewed and evaluated for demographics, surgical procedure, and types of IVAD, complications post implantation and possible associated factors with the complications studied. All the information collected and analyzed with SPSS programme 22.0. Results: There were 197 patients included in this study which involved 54.3% male patients and 45.7% female patients. The procedure performed by orthopaedic surgeons in 132(67%) patients, 65 patients (33%) performed by the medical officers. All patients received intravenous antibiotic prophylaxis, Cefuroxime prior to implantation. The mean duration of surgery was 59.37 minutes while the mean duration of follow up, was 715 days. The overall complication rate was 12.7% (n= 25). There were 7.6% (n=15) infection rate, 3.6% (n=7) thrombosis, 1.0% (n= 2) for fracture and migration and 0.5% (n=1) mal-position of IVAD. There was no association between the types of catheter with the overall complication rate. There was an association between the types of cancer with the infections rate. We found no association between age and absolute neutrophil count (ANC) with the infection rates and the platelet levels with thrombosis rates. Conclusions: Cephalic vein cut down approach is a safe approach for IVAD implantation with an overall low rate of complications. These treatments offer an alternative and provide benefits to patients in HUSM. 2018 Thesis NonPeerReviewed application/pdf en http://eprints.usm.my/48550/1/Dr.%20Sobri%20Nor-24%20pages.pdf Nor, Sobri (2018) A five years review of complications of implantable venous access devices (IVAD) in cancer patient through the cephalic vein cut down approach. Masters thesis, Universiti Sains Malaysia.
institution Universiti Sains Malaysia
building Hamzah Sendut Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Sains Malaysia
content_source USM Institutional Repository
url_provider http://eprints.usm.my/
language English
topic RC666-701 Diseases of the circulatory (Cardiovascular) system
spellingShingle RC666-701 Diseases of the circulatory (Cardiovascular) system
Nor, Sobri
A five years review of complications of implantable venous access devices (IVAD) in cancer patient through the cephalic vein cut down approach
description Introduction: Implanted venous access device (IVAD) is one of the options that give access to the central venous circulation. It is widely used nowadays and can be used for various reasons. It can be retained in the body for a period of up to two years with minimal care and low risk of infection thus it is suitable for patients especially for those who had the difficult vascular access example in cancer patients. Cephalic vein cut down approach is one of the methods of insertion of IVAD with minimal complication associated to this technique, however, it is not widely used as it needs to be done in operating theatre setting and it took longer duration. This study was done to evaluate the complication of the IVAD that implanted in cancer patient through cephalic vein cut down approach. Methodology: This is a retrospective study involving cancer patients that were implanted with IVAD through cephalic vein cut-down approach in HUSM from January 2010 to December 2014. All medical records reviewed and evaluated for demographics, surgical procedure, and types of IVAD, complications post implantation and possible associated factors with the complications studied. All the information collected and analyzed with SPSS programme 22.0. Results: There were 197 patients included in this study which involved 54.3% male patients and 45.7% female patients. The procedure performed by orthopaedic surgeons in 132(67%) patients, 65 patients (33%) performed by the medical officers. All patients received intravenous antibiotic prophylaxis, Cefuroxime prior to implantation. The mean duration of surgery was 59.37 minutes while the mean duration of follow up, was 715 days. The overall complication rate was 12.7% (n= 25). There were 7.6% (n=15) infection rate, 3.6% (n=7) thrombosis, 1.0% (n= 2) for fracture and migration and 0.5% (n=1) mal-position of IVAD. There was no association between the types of catheter with the overall complication rate. There was an association between the types of cancer with the infections rate. We found no association between age and absolute neutrophil count (ANC) with the infection rates and the platelet levels with thrombosis rates. Conclusions: Cephalic vein cut down approach is a safe approach for IVAD implantation with an overall low rate of complications. These treatments offer an alternative and provide benefits to patients in HUSM.
format Thesis
author Nor, Sobri
author_facet Nor, Sobri
author_sort Nor, Sobri
title A five years review of complications of implantable venous access devices (IVAD) in cancer patient through the cephalic vein cut down approach
title_short A five years review of complications of implantable venous access devices (IVAD) in cancer patient through the cephalic vein cut down approach
title_full A five years review of complications of implantable venous access devices (IVAD) in cancer patient through the cephalic vein cut down approach
title_fullStr A five years review of complications of implantable venous access devices (IVAD) in cancer patient through the cephalic vein cut down approach
title_full_unstemmed A five years review of complications of implantable venous access devices (IVAD) in cancer patient through the cephalic vein cut down approach
title_sort five years review of complications of implantable venous access devices (ivad) in cancer patient through the cephalic vein cut down approach
publishDate 2018
url http://eprints.usm.my/48550/1/Dr.%20Sobri%20Nor-24%20pages.pdf
http://eprints.usm.my/48550/
_version_ 1693726889086025728