Performance Of Micro Steam Engine

Steam engines were the first engine type to see widespread use. It was the foundation of the industrial revolution. This study is done to investigate the performance and specification of the components that make up the Micro Wobbler Steam Engine. The system comprise of 3 parts namely the boiler, the...

Full description

Saved in:
Bibliographic Details
Main Author: Louis, Mark Selvan Anthony Rogers
Format: Monograph
Language:English
Published: Universiti Sains Malaysia 2017
Subjects:
Online Access:http://eprints.usm.my/53986/1/Performance%20Of%20Micro%20Steam%20Engine_Mark%20Selvan%20%20Anthony%20Rogers%20Louis_M4_2017.pdf
http://eprints.usm.my/53986/
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Universiti Sains Malaysia
Language: English
id my.usm.eprints.53986
record_format eprints
spelling my.usm.eprints.53986 http://eprints.usm.my/53986/ Performance Of Micro Steam Engine Louis, Mark Selvan Anthony Rogers T Technology Steam engines were the first engine type to see widespread use. It was the foundation of the industrial revolution. This study is done to investigate the performance and specification of the components that make up the Micro Wobbler Steam Engine. The system comprise of 3 parts namely the boiler, the pressure regulating valve and the steam engine. The LPG fired boiler is a vertical fire tube boiler with a 7.5 L capacity and a maximum operating pressure of 10 Bar. The pressure regulating valve is a Yoshitake GD 45P that is compact, lightweight and with a minimum inlet pressure of 2 Bar. The steam engine is Micro Wobbler Steam engine. The performance of the system was determined by varying the inlet pressure and the load while measuring the flowrate and torque. Subsequently, the brake power, indicated power, friction power, brake thermal efficiency and mechanical efficiency were calculated. From the experiment carried out, the highest brake power, indicated power and friction power were 4.35 Watts, 17.4 Watts and 13.05 Watts. The highest indicated thermal efficiency was 0.23% while the mechanical efficiency remained constant at 25%. Whereas the boiler efficiency was 43%. The results indicates a relatively low overall efficiency of the system that is 0.056%. Universiti Sains Malaysia 2017-05-01 Monograph NonPeerReviewed application/pdf en http://eprints.usm.my/53986/1/Performance%20Of%20Micro%20Steam%20Engine_Mark%20Selvan%20%20Anthony%20Rogers%20Louis_M4_2017.pdf Louis, Mark Selvan Anthony Rogers (2017) Performance Of Micro Steam Engine. Project Report. Universiti Sains Malaysia, Pusat Pengajian Kejuruteraan Mekanik. (Submitted)
institution Universiti Sains Malaysia
building Hamzah Sendut Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Sains Malaysia
content_source USM Institutional Repository
url_provider http://eprints.usm.my/
language English
topic T Technology
spellingShingle T Technology
Louis, Mark Selvan Anthony Rogers
Performance Of Micro Steam Engine
description Steam engines were the first engine type to see widespread use. It was the foundation of the industrial revolution. This study is done to investigate the performance and specification of the components that make up the Micro Wobbler Steam Engine. The system comprise of 3 parts namely the boiler, the pressure regulating valve and the steam engine. The LPG fired boiler is a vertical fire tube boiler with a 7.5 L capacity and a maximum operating pressure of 10 Bar. The pressure regulating valve is a Yoshitake GD 45P that is compact, lightweight and with a minimum inlet pressure of 2 Bar. The steam engine is Micro Wobbler Steam engine. The performance of the system was determined by varying the inlet pressure and the load while measuring the flowrate and torque. Subsequently, the brake power, indicated power, friction power, brake thermal efficiency and mechanical efficiency were calculated. From the experiment carried out, the highest brake power, indicated power and friction power were 4.35 Watts, 17.4 Watts and 13.05 Watts. The highest indicated thermal efficiency was 0.23% while the mechanical efficiency remained constant at 25%. Whereas the boiler efficiency was 43%. The results indicates a relatively low overall efficiency of the system that is 0.056%.
format Monograph
author Louis, Mark Selvan Anthony Rogers
author_facet Louis, Mark Selvan Anthony Rogers
author_sort Louis, Mark Selvan Anthony Rogers
title Performance Of Micro Steam Engine
title_short Performance Of Micro Steam Engine
title_full Performance Of Micro Steam Engine
title_fullStr Performance Of Micro Steam Engine
title_full_unstemmed Performance Of Micro Steam Engine
title_sort performance of micro steam engine
publisher Universiti Sains Malaysia
publishDate 2017
url http://eprints.usm.my/53986/1/Performance%20Of%20Micro%20Steam%20Engine_Mark%20Selvan%20%20Anthony%20Rogers%20Louis_M4_2017.pdf
http://eprints.usm.my/53986/
_version_ 1740826604080201728