Developing Flow In Microchannel Having Regular Microstructure
Microchannel is used as compact heat exchangers or microcoolers in electronics packaging in many engineering system. The system performance depends on laminar flow development in the microchannels. Sometimes, the use of short microchannel lengths is insufficient to yield a fully developed flow. In...
Saved in:
Main Author: | |
---|---|
Format: | Monograph |
Language: | English |
Published: |
Universiti Sains Malaysia
2018
|
Subjects: | |
Online Access: | http://eprints.usm.my/54183/1/Developing%20Flow%20In%20Microchannel%20Having%20Regular%20Microstructure_Tan%20Yan%20Xu_M4_2018.pdf http://eprints.usm.my/54183/ |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Institution: | Universiti Sains Malaysia |
Language: | English |
id |
my.usm.eprints.54183 |
---|---|
record_format |
eprints |
spelling |
my.usm.eprints.54183 http://eprints.usm.my/54183/ Developing Flow In Microchannel Having Regular Microstructure Tan, Yan Xu T Technology TJ Mechanical engineering and machinery Microchannel is used as compact heat exchangers or microcoolers in electronics packaging in many engineering system. The system performance depends on laminar flow development in the microchannels. Sometimes, the use of short microchannel lengths is insufficient to yield a fully developed flow. In other words, only developing flow could prevail along the channel length. Thus, it is essential to determine the distance needed for a flowing liquid before a fully developed flow condition could prevail. The main objective of the work is focused on exploring the effects of different surface topologies on the hydrodynamic entrance region in the channels. This study is carried out by using ANSYS FLUENT 16.1, a finite volume based computational fluid dynamics (CFD) software package to simulate the fluid flow in parallel plate and rectangular microchannel having regular microstructure. The data obtained from the simulation are then processed by using MATLAB to determine the hydrodynamic entrance length. As expected, regular microstructure has the effect on hydrodynamic entrance length of both increasing and decreasing the hydrodynamic entrance length of parallel plate and rectangular microchannel with its microstructure parameter of dimensionless period extent of groove-rib combination, L and no slip fraction δ. Universiti Sains Malaysia 2018-05-01 Monograph NonPeerReviewed application/pdf en http://eprints.usm.my/54183/1/Developing%20Flow%20In%20Microchannel%20Having%20Regular%20Microstructure_Tan%20Yan%20Xu_M4_2018.pdf Tan, Yan Xu (2018) Developing Flow In Microchannel Having Regular Microstructure. Project Report. Universiti Sains Malaysia, Pusat Pengajian Kejuruteraan Mekanikal. (Submitted) |
institution |
Universiti Sains Malaysia |
building |
Hamzah Sendut Library |
collection |
Institutional Repository |
continent |
Asia |
country |
Malaysia |
content_provider |
Universiti Sains Malaysia |
content_source |
USM Institutional Repository |
url_provider |
http://eprints.usm.my/ |
language |
English |
topic |
T Technology TJ Mechanical engineering and machinery |
spellingShingle |
T Technology TJ Mechanical engineering and machinery Tan, Yan Xu Developing Flow In Microchannel Having Regular Microstructure |
description |
Microchannel is used as compact heat exchangers or microcoolers in electronics packaging in many engineering system. The system performance depends on laminar flow development in the microchannels. Sometimes, the use of short microchannel
lengths is insufficient to yield a fully developed flow. In other words, only developing flow could prevail along the channel length. Thus, it is essential to determine the
distance needed for a flowing liquid before a fully developed flow condition could prevail. The main objective of the work is focused on exploring the effects of different surface topologies on the hydrodynamic entrance region in the channels. This study is carried out by using ANSYS FLUENT 16.1, a finite volume based computational fluid dynamics (CFD) software package to simulate the fluid flow in parallel plate and
rectangular microchannel having regular microstructure. The data obtained from the simulation are then processed by using MATLAB to determine the hydrodynamic entrance length. As expected, regular microstructure has the effect on hydrodynamic
entrance length of both increasing and decreasing the hydrodynamic entrance length of parallel plate and rectangular microchannel with its microstructure parameter of dimensionless period extent of groove-rib combination, L and no slip fraction δ. |
format |
Monograph |
author |
Tan, Yan Xu |
author_facet |
Tan, Yan Xu |
author_sort |
Tan, Yan Xu |
title |
Developing Flow In Microchannel Having Regular Microstructure |
title_short |
Developing Flow In Microchannel Having Regular Microstructure |
title_full |
Developing Flow In Microchannel Having Regular Microstructure |
title_fullStr |
Developing Flow In Microchannel Having Regular Microstructure |
title_full_unstemmed |
Developing Flow In Microchannel Having Regular Microstructure |
title_sort |
developing flow in microchannel having regular microstructure |
publisher |
Universiti Sains Malaysia |
publishDate |
2018 |
url |
http://eprints.usm.my/54183/1/Developing%20Flow%20In%20Microchannel%20Having%20Regular%20Microstructure_Tan%20Yan%20Xu_M4_2018.pdf http://eprints.usm.my/54183/ |
_version_ |
1743107796099923968 |