Optimization of the differential pulse anodic stripping voltammetry technique for determination of cadmium in Pengkalan Chepa River, Kelantan

Cadmium is one of heavy metal that can cause river water pollution by waste from factories. Common exposure of human or animal towards cadmium will cause toxicity. In determination of cadmium, voltammetric technique was used since it is highly sensitive, low cost and low limit of detection. This...

Full description

Saved in:
Bibliographic Details
Main Author: Zulkiply, Nor Amalina
Format: Monograph
Language:English
Published: Universiti Sains Malaysia 2009
Subjects:
Online Access:http://eprints.usm.my/59502/1/NOR%20AMALINA%20BINTI%20ZULKIPLY%20-%20e.pdf
http://eprints.usm.my/59502/
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Universiti Sains Malaysia
Language: English
id my.usm.eprints.59502
record_format eprints
spelling my.usm.eprints.59502 http://eprints.usm.my/59502/ Optimization of the differential pulse anodic stripping voltammetry technique for determination of cadmium in Pengkalan Chepa River, Kelantan Zulkiply, Nor Amalina TD878-894 Special types of environment. Including soil pollution, air pollution, noise pollution Cadmium is one of heavy metal that can cause river water pollution by waste from factories. Common exposure of human or animal towards cadmium will cause toxicity. In determination of cadmium, voltammetric technique was used since it is highly sensitive, low cost and low limit of detection. This technique was used for qualitative and quantitative determination of cadmium in water samples. Samples were collected from five rivers; Sungai Alor B, Sungai Alor Lintah, Sungai Keladi, Sungai Pengkalan Chepa and Sungai Pengkalan Chepa 2 which are tributaries of main river, Pengkalan Chepa River at different depth (surface and bottom). Differential Pulse Anodic Stripping Voltammetry (DPSA V) technique was carried out using three electrodes, hanging mercury drop electrode (HMDE) act as working electrode, Ag/AgCI/KCI saturated act as reference electrode and platinum electrode act as auxiliary electrode. The supporting electrolyte used was acetate buffer (1.38 M, pH 4.6). The optimum voltammetric parameters to determine cadmium in river water were initial potential (Ei) -1 V, final potential (Er) -0.2 V, scan rate (v) 5 mV/s, voltage step 0.005 V, voltage step time 1 s, deposition potential (Eacc) -1 V, deposition time (tacc) 60s and equilibrium time (teq) 1000 s. Using this optimized parameters, peak potential (Ep) for cadmium standard was found at -0.632 V. The linear range of cadmium was observed over the concentration range 0.26 ppm to 1.32 ppm with correlation coefficient (r) 0.993, standard deviation (SD) 0.500, sensitivity 10.227 nA/ppm and limit of detection 147 ppb. The method had been successfully applied for determination of cadmium in real samples. The results showed that cadmium was absent in all the samples. Universiti Sains Malaysia 2009 Monograph NonPeerReviewed application/pdf en http://eprints.usm.my/59502/1/NOR%20AMALINA%20BINTI%20ZULKIPLY%20-%20e.pdf Zulkiply, Nor Amalina (2009) Optimization of the differential pulse anodic stripping voltammetry technique for determination of cadmium in Pengkalan Chepa River, Kelantan. Project Report. Universiti Sains Malaysia. (Submitted)
institution Universiti Sains Malaysia
building Hamzah Sendut Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Sains Malaysia
content_source USM Institutional Repository
url_provider http://eprints.usm.my/
language English
topic TD878-894 Special types of environment. Including soil pollution, air pollution, noise pollution
spellingShingle TD878-894 Special types of environment. Including soil pollution, air pollution, noise pollution
Zulkiply, Nor Amalina
Optimization of the differential pulse anodic stripping voltammetry technique for determination of cadmium in Pengkalan Chepa River, Kelantan
description Cadmium is one of heavy metal that can cause river water pollution by waste from factories. Common exposure of human or animal towards cadmium will cause toxicity. In determination of cadmium, voltammetric technique was used since it is highly sensitive, low cost and low limit of detection. This technique was used for qualitative and quantitative determination of cadmium in water samples. Samples were collected from five rivers; Sungai Alor B, Sungai Alor Lintah, Sungai Keladi, Sungai Pengkalan Chepa and Sungai Pengkalan Chepa 2 which are tributaries of main river, Pengkalan Chepa River at different depth (surface and bottom). Differential Pulse Anodic Stripping Voltammetry (DPSA V) technique was carried out using three electrodes, hanging mercury drop electrode (HMDE) act as working electrode, Ag/AgCI/KCI saturated act as reference electrode and platinum electrode act as auxiliary electrode. The supporting electrolyte used was acetate buffer (1.38 M, pH 4.6). The optimum voltammetric parameters to determine cadmium in river water were initial potential (Ei) -1 V, final potential (Er) -0.2 V, scan rate (v) 5 mV/s, voltage step 0.005 V, voltage step time 1 s, deposition potential (Eacc) -1 V, deposition time (tacc) 60s and equilibrium time (teq) 1000 s. Using this optimized parameters, peak potential (Ep) for cadmium standard was found at -0.632 V. The linear range of cadmium was observed over the concentration range 0.26 ppm to 1.32 ppm with correlation coefficient (r) 0.993, standard deviation (SD) 0.500, sensitivity 10.227 nA/ppm and limit of detection 147 ppb. The method had been successfully applied for determination of cadmium in real samples. The results showed that cadmium was absent in all the samples.
format Monograph
author Zulkiply, Nor Amalina
author_facet Zulkiply, Nor Amalina
author_sort Zulkiply, Nor Amalina
title Optimization of the differential pulse anodic stripping voltammetry technique for determination of cadmium in Pengkalan Chepa River, Kelantan
title_short Optimization of the differential pulse anodic stripping voltammetry technique for determination of cadmium in Pengkalan Chepa River, Kelantan
title_full Optimization of the differential pulse anodic stripping voltammetry technique for determination of cadmium in Pengkalan Chepa River, Kelantan
title_fullStr Optimization of the differential pulse anodic stripping voltammetry technique for determination of cadmium in Pengkalan Chepa River, Kelantan
title_full_unstemmed Optimization of the differential pulse anodic stripping voltammetry technique for determination of cadmium in Pengkalan Chepa River, Kelantan
title_sort optimization of the differential pulse anodic stripping voltammetry technique for determination of cadmium in pengkalan chepa river, kelantan
publisher Universiti Sains Malaysia
publishDate 2009
url http://eprints.usm.my/59502/1/NOR%20AMALINA%20BINTI%20ZULKIPLY%20-%20e.pdf
http://eprints.usm.my/59502/
_version_ 1783877481951920128