Delineation Of Seulimeum Fault System And Identification Of Geothermal Signatures Using Ground Magnetic And 2-D Resistivity Imaging Methods

Ground magnetic and 2-D resistivity imaging method are widely used in geophysical exploration for subsurface identification to study the earth rheology such as fault process based on the geophysical parameter. Ground magnetic and 2-D resistivity imaging surveys were conducted to investigate the t...

Full description

Saved in:
Bibliographic Details
Main Author: Zakaria, Muhammad Taqiuddin
Format: Thesis
Language:English
Published: 2017
Subjects:
Online Access:http://eprints.usm.my/61183/1/24%20Pages%20from%20PHS18020037.pdf
http://eprints.usm.my/61183/
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Universiti Sains Malaysia
Language: English
id my.usm.eprints.61183
record_format eprints
spelling my.usm.eprints.61183 http://eprints.usm.my/61183/ Delineation Of Seulimeum Fault System And Identification Of Geothermal Signatures Using Ground Magnetic And 2-D Resistivity Imaging Methods Zakaria, Muhammad Taqiuddin QC1 Physics (General) Ground magnetic and 2-D resistivity imaging method are widely used in geophysical exploration for subsurface identification to study the earth rheology such as fault process based on the geophysical parameter. Ground magnetic and 2-D resistivity imaging surveys were conducted to investigate the trend of Seulimeum fault system and the signature of potential geothermal surface manifestation resulting from the fault. Four different sites, namely Krueng Raya, Iejue, Lamtamot, and Tangse were chosen as study area for Seulimeum fault study while two sites; lejue and Ie-Seu 'Urn were chosen as case study areas in identifying the geothermal signatures. Ground magnetic method was performed using proton magnetometer while the 2-D resistivity imaging survey was done using ABEM Terrameter with Pole-dipole array. The magnetic residual contour map in Krueng Raya locality shows the dislocation from northwest to southeast (NW-SE) direction with contrast of high and low magnetic residual ranging from -150 nT to 300 nT which interpreted as the geological fault. In Iejue site the result shows the contrast of magnetic residual between -150 nT to 300 nT which indicate as geological fault continuous from Krueng Raya. 2017-02 Thesis NonPeerReviewed application/pdf en http://eprints.usm.my/61183/1/24%20Pages%20from%20PHS18020037.pdf Zakaria, Muhammad Taqiuddin (2017) Delineation Of Seulimeum Fault System And Identification Of Geothermal Signatures Using Ground Magnetic And 2-D Resistivity Imaging Methods. Masters thesis, Perpustakaan Hamzah Sendut.
institution Universiti Sains Malaysia
building Hamzah Sendut Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Sains Malaysia
content_source USM Institutional Repository
url_provider http://eprints.usm.my/
language English
topic QC1 Physics (General)
spellingShingle QC1 Physics (General)
Zakaria, Muhammad Taqiuddin
Delineation Of Seulimeum Fault System And Identification Of Geothermal Signatures Using Ground Magnetic And 2-D Resistivity Imaging Methods
description Ground magnetic and 2-D resistivity imaging method are widely used in geophysical exploration for subsurface identification to study the earth rheology such as fault process based on the geophysical parameter. Ground magnetic and 2-D resistivity imaging surveys were conducted to investigate the trend of Seulimeum fault system and the signature of potential geothermal surface manifestation resulting from the fault. Four different sites, namely Krueng Raya, Iejue, Lamtamot, and Tangse were chosen as study area for Seulimeum fault study while two sites; lejue and Ie-Seu 'Urn were chosen as case study areas in identifying the geothermal signatures. Ground magnetic method was performed using proton magnetometer while the 2-D resistivity imaging survey was done using ABEM Terrameter with Pole-dipole array. The magnetic residual contour map in Krueng Raya locality shows the dislocation from northwest to southeast (NW-SE) direction with contrast of high and low magnetic residual ranging from -150 nT to 300 nT which interpreted as the geological fault. In Iejue site the result shows the contrast of magnetic residual between -150 nT to 300 nT which indicate as geological fault continuous from Krueng Raya.
format Thesis
author Zakaria, Muhammad Taqiuddin
author_facet Zakaria, Muhammad Taqiuddin
author_sort Zakaria, Muhammad Taqiuddin
title Delineation Of Seulimeum Fault System And Identification Of Geothermal Signatures Using Ground Magnetic And 2-D Resistivity Imaging Methods
title_short Delineation Of Seulimeum Fault System And Identification Of Geothermal Signatures Using Ground Magnetic And 2-D Resistivity Imaging Methods
title_full Delineation Of Seulimeum Fault System And Identification Of Geothermal Signatures Using Ground Magnetic And 2-D Resistivity Imaging Methods
title_fullStr Delineation Of Seulimeum Fault System And Identification Of Geothermal Signatures Using Ground Magnetic And 2-D Resistivity Imaging Methods
title_full_unstemmed Delineation Of Seulimeum Fault System And Identification Of Geothermal Signatures Using Ground Magnetic And 2-D Resistivity Imaging Methods
title_sort delineation of seulimeum fault system and identification of geothermal signatures using ground magnetic and 2-d resistivity imaging methods
publishDate 2017
url http://eprints.usm.my/61183/1/24%20Pages%20from%20PHS18020037.pdf
http://eprints.usm.my/61183/
_version_ 1811683111317012480