Delineation Of Seulimeum Fault System And Identification Of Geothermal Signatures Using Ground Magnetic And 2-D Resistivity Imaging Methods
Ground magnetic and 2-D resistivity imaging method are widely used in geophysical exploration for subsurface identification to study the earth rheology such as fault process based on the geophysical parameter. Ground magnetic and 2-D resistivity imaging surveys were conducted to investigate the t...
Saved in:
Main Author: | |
---|---|
Format: | Thesis |
Language: | English |
Published: |
2017
|
Subjects: | |
Online Access: | http://eprints.usm.my/61183/1/24%20Pages%20from%20PHS18020037.pdf http://eprints.usm.my/61183/ |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Institution: | Universiti Sains Malaysia |
Language: | English |
id |
my.usm.eprints.61183 |
---|---|
record_format |
eprints |
spelling |
my.usm.eprints.61183 http://eprints.usm.my/61183/ Delineation Of Seulimeum Fault System And Identification Of Geothermal Signatures Using Ground Magnetic And 2-D Resistivity Imaging Methods Zakaria, Muhammad Taqiuddin QC1 Physics (General) Ground magnetic and 2-D resistivity imaging method are widely used in geophysical exploration for subsurface identification to study the earth rheology such as fault process based on the geophysical parameter. Ground magnetic and 2-D resistivity imaging surveys were conducted to investigate the trend of Seulimeum fault system and the signature of potential geothermal surface manifestation resulting from the fault. Four different sites, namely Krueng Raya, Iejue, Lamtamot, and Tangse were chosen as study area for Seulimeum fault study while two sites; lejue and Ie-Seu 'Urn were chosen as case study areas in identifying the geothermal signatures. Ground magnetic method was performed using proton magnetometer while the 2-D resistivity imaging survey was done using ABEM Terrameter with Pole-dipole array. The magnetic residual contour map in Krueng Raya locality shows the dislocation from northwest to southeast (NW-SE) direction with contrast of high and low magnetic residual ranging from -150 nT to 300 nT which interpreted as the geological fault. In Iejue site the result shows the contrast of magnetic residual between -150 nT to 300 nT which indicate as geological fault continuous from Krueng Raya. 2017-02 Thesis NonPeerReviewed application/pdf en http://eprints.usm.my/61183/1/24%20Pages%20from%20PHS18020037.pdf Zakaria, Muhammad Taqiuddin (2017) Delineation Of Seulimeum Fault System And Identification Of Geothermal Signatures Using Ground Magnetic And 2-D Resistivity Imaging Methods. Masters thesis, Perpustakaan Hamzah Sendut. |
institution |
Universiti Sains Malaysia |
building |
Hamzah Sendut Library |
collection |
Institutional Repository |
continent |
Asia |
country |
Malaysia |
content_provider |
Universiti Sains Malaysia |
content_source |
USM Institutional Repository |
url_provider |
http://eprints.usm.my/ |
language |
English |
topic |
QC1 Physics (General) |
spellingShingle |
QC1 Physics (General) Zakaria, Muhammad Taqiuddin Delineation Of Seulimeum Fault System And Identification Of Geothermal Signatures Using Ground Magnetic And 2-D Resistivity Imaging Methods |
description |
Ground magnetic and 2-D resistivity imaging method are widely used in
geophysical exploration for subsurface identification to study the earth rheology such
as fault process based on the geophysical parameter. Ground magnetic and 2-D
resistivity imaging surveys were conducted to investigate the trend of Seulimeum
fault system and the signature of potential geothermal surface manifestation resulting
from the fault. Four different sites, namely Krueng Raya, Iejue, Lamtamot, and
Tangse were chosen as study area for Seulimeum fault study while two sites; lejue
and Ie-Seu 'Urn were chosen as case study areas in identifying the geothermal
signatures. Ground magnetic method was performed using proton magnetometer
while the 2-D resistivity imaging survey was done using ABEM Terrameter with
Pole-dipole array. The magnetic residual contour map in Krueng Raya locality shows
the dislocation from northwest to southeast (NW-SE) direction with contrast of high
and low magnetic residual ranging from -150 nT to 300 nT which interpreted as the
geological fault. In Iejue site the result shows the contrast of magnetic residual
between -150 nT to 300 nT which indicate as geological fault continuous from
Krueng Raya. |
format |
Thesis |
author |
Zakaria, Muhammad Taqiuddin |
author_facet |
Zakaria, Muhammad Taqiuddin |
author_sort |
Zakaria, Muhammad Taqiuddin |
title |
Delineation Of Seulimeum Fault System And Identification Of
Geothermal Signatures Using Ground Magnetic And 2-D Resistivity Imaging Methods |
title_short |
Delineation Of Seulimeum Fault System And Identification Of
Geothermal Signatures Using Ground Magnetic And 2-D Resistivity Imaging Methods |
title_full |
Delineation Of Seulimeum Fault System And Identification Of
Geothermal Signatures Using Ground Magnetic And 2-D Resistivity Imaging Methods |
title_fullStr |
Delineation Of Seulimeum Fault System And Identification Of
Geothermal Signatures Using Ground Magnetic And 2-D Resistivity Imaging Methods |
title_full_unstemmed |
Delineation Of Seulimeum Fault System And Identification Of
Geothermal Signatures Using Ground Magnetic And 2-D Resistivity Imaging Methods |
title_sort |
delineation of seulimeum fault system and identification of
geothermal signatures using ground magnetic and 2-d resistivity imaging methods |
publishDate |
2017 |
url |
http://eprints.usm.my/61183/1/24%20Pages%20from%20PHS18020037.pdf http://eprints.usm.my/61183/ |
_version_ |
1811683111317012480 |