Speed performance of space vector pulse width modulation direct torque for five leg inverter served dual three-phase induction motor
Independent control of multi-machine with singleconverter systems is the motivation of this research study. As in the previous literature review, there is no report regarding speed control applying space vector pulse width modulation direct torque control (SVPWM-DTC) method for dual three-phase in...
Saved in:
Main Authors: | , , |
---|---|
Format: | Conference or Workshop Item |
Language: | English |
Published: |
2012
|
Subjects: | |
Online Access: | http://eprints.utem.edu.my/id/eprint/15153/1/Speed%20performance%20of%20space%20vector%20pulse%20width%20modulation%20direct%20torque%20for%20five%20leg%20inverter%20served%20dual%20three-phase%20induction%20motor194.pdf http://eprints.utem.edu.my/id/eprint/15153/ |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Institution: | Universiti Teknikal Malaysia Melaka |
Language: | English |
id |
my.utem.eprints.15153 |
---|---|
record_format |
eprints |
spelling |
my.utem.eprints.151532015-10-29T08:14:11Z http://eprints.utem.edu.my/id/eprint/15153/ Speed performance of space vector pulse width modulation direct torque for five leg inverter served dual three-phase induction motor N.M., Yaakop Zulkifilie, Ibrahim Md Hairul Nizam , Talib TK Electrical engineering. Electronics Nuclear engineering Independent control of multi-machine with singleconverter systems is the motivation of this research study. As in the previous literature review, there is no report regarding speed control applying space vector pulse width modulation direct torque control (SVPWM-DTC) method for dual three-phase induction motor (IM) fed by a five leg inverter (FLI). Therefore, in this paper, a new and simple control method based on SVPWM-DTC for dual three-phase induction motors with only one drive of five-leg voltage source inverter is investigated. The method effectively allows independent control of two three-phase IMs. Simulations of different speed commands and variation of load condition tests have been performed. Future work is to do comparative study between vector controls (VC) versus DTC methods to the FLI performance. 2012 Conference or Workshop Item PeerReviewed text en http://eprints.utem.edu.my/id/eprint/15153/1/Speed%20performance%20of%20space%20vector%20pulse%20width%20modulation%20direct%20torque%20for%20five%20leg%20inverter%20served%20dual%20three-phase%20induction%20motor194.pdf N.M., Yaakop and Zulkifilie, Ibrahim and Md Hairul Nizam , Talib (2012) Speed performance of space vector pulse width modulation direct torque for five leg inverter served dual three-phase induction motor. In: 2012 Ieee International Power Engineering and Optimization Conference (PEDCO) Melaka, Malaysia, 6-7 June 2012, Melaka. (Submitted) |
institution |
Universiti Teknikal Malaysia Melaka |
building |
UTEM Library |
collection |
Institutional Repository |
continent |
Asia |
country |
Malaysia |
content_provider |
Universiti Teknikal Malaysia Melaka |
content_source |
UTEM Institutional Repository |
url_provider |
http://eprints.utem.edu.my/ |
language |
English |
topic |
TK Electrical engineering. Electronics Nuclear engineering |
spellingShingle |
TK Electrical engineering. Electronics Nuclear engineering N.M., Yaakop Zulkifilie, Ibrahim Md Hairul Nizam , Talib Speed performance of space vector pulse width modulation direct torque for five leg inverter served dual three-phase induction motor |
description |
Independent control of multi-machine with singleconverter
systems is the motivation of this research study. As in
the previous literature review, there is no report regarding speed control applying space vector pulse width modulation direct torque control (SVPWM-DTC) method for dual three-phase induction motor (IM) fed by a five leg inverter (FLI). Therefore, in this paper, a new and simple control method based on SVPWM-DTC for dual three-phase induction motors with only one drive of five-leg voltage source inverter is investigated. The method effectively allows independent control of two three-phase
IMs. Simulations of different speed commands and variation of load condition tests have been performed. Future work is to do comparative study between vector controls (VC) versus DTC methods to the FLI performance. |
format |
Conference or Workshop Item |
author |
N.M., Yaakop Zulkifilie, Ibrahim Md Hairul Nizam , Talib |
author_facet |
N.M., Yaakop Zulkifilie, Ibrahim Md Hairul Nizam , Talib |
author_sort |
N.M., Yaakop |
title |
Speed performance of space vector pulse width modulation direct torque for five leg inverter served dual three-phase induction motor |
title_short |
Speed performance of space vector pulse width modulation direct torque for five leg inverter served dual three-phase induction motor |
title_full |
Speed performance of space vector pulse width modulation direct torque for five leg inverter served dual three-phase induction motor |
title_fullStr |
Speed performance of space vector pulse width modulation direct torque for five leg inverter served dual three-phase induction motor |
title_full_unstemmed |
Speed performance of space vector pulse width modulation direct torque for five leg inverter served dual three-phase induction motor |
title_sort |
speed performance of space vector pulse width modulation direct torque for five leg inverter served dual three-phase induction motor |
publishDate |
2012 |
url |
http://eprints.utem.edu.my/id/eprint/15153/1/Speed%20performance%20of%20space%20vector%20pulse%20width%20modulation%20direct%20torque%20for%20five%20leg%20inverter%20served%20dual%20three-phase%20induction%20motor194.pdf http://eprints.utem.edu.my/id/eprint/15153/ |
_version_ |
1665905633294024704 |