The impact of embedded generation due to harmonic performance
The paper investigates the most suitable location of inverter connection installed into the distribution line feeder. Thus, it can reduce losses, control voltages as well as the protection system. Besides, it is more focused on mitigated a whack-a-mole phenomenon due to its fifth and seventh harmoni...
Saved in:
Main Authors: | , , |
---|---|
Format: | Conference or Workshop Item |
Language: | English |
Published: |
2009
|
Subjects: | |
Online Access: | http://eprints.utem.edu.my/id/eprint/15162/1/The%20impact%20of%20embedded%20generation%20due%20to%20harmonic%20performance242.pdf http://eprints.utem.edu.my/id/eprint/15162/ |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Institution: | Universiti Teknikal Malaysia Melaka |
Language: | English |
id |
my.utem.eprints.15162 |
---|---|
record_format |
eprints |
spelling |
my.utem.eprints.151622015-10-29T08:06:45Z http://eprints.utem.edu.my/id/eprint/15162/ The impact of embedded generation due to harmonic performance Aziah, Khamis Matthew, Armstrong Marizan, Sulaiman TK Electrical engineering. Electronics Nuclear engineering The paper investigates the most suitable location of inverter connection installed into the distribution line feeder. Thus, it can reduce losses, control voltages as well as the protection system. Besides, it is more focused on mitigated a whack-a-mole phenomenon due to its fifth and seventh harmonics. Whack-a-mole phenomenon occurs as an active filter or passive filter installed on the long feeder line. It effect harmonic voltage where increase on some busses and decrease on other busses, especially at point of installation. In this paper, the inverter replaced by directly connected with the current source. Thus, parallels current source with combination of fundamental, third, fifth and seventh harmonic frequencies were tested. From the analysis, the best location of inverter current source should be at least lambda/4 from end bus. Thus, it proves by looking into its harmonic voltage, harmonic current and total harmonics distortion (THD) performance 2009 Conference or Workshop Item PeerReviewed text en http://eprints.utem.edu.my/id/eprint/15162/1/The%20impact%20of%20embedded%20generation%20due%20to%20harmonic%20performance242.pdf Aziah, Khamis and Matthew, Armstrong and Marizan, Sulaiman (2009) The impact of embedded generation due to harmonic performance. In: Third Asia International Conference on Modelling & Simulation, 2009. AMS '09, 25-29 May 2009, Bali, Indonesia. (Submitted) |
institution |
Universiti Teknikal Malaysia Melaka |
building |
UTEM Library |
collection |
Institutional Repository |
continent |
Asia |
country |
Malaysia |
content_provider |
Universiti Teknikal Malaysia Melaka |
content_source |
UTEM Institutional Repository |
url_provider |
http://eprints.utem.edu.my/ |
language |
English |
topic |
TK Electrical engineering. Electronics Nuclear engineering |
spellingShingle |
TK Electrical engineering. Electronics Nuclear engineering Aziah, Khamis Matthew, Armstrong Marizan, Sulaiman The impact of embedded generation due to harmonic performance |
description |
The paper investigates the most suitable location of inverter connection installed into the distribution line feeder. Thus, it can reduce losses, control voltages as well as the protection system. Besides, it is more focused on mitigated a whack-a-mole phenomenon due to its fifth and seventh harmonics. Whack-a-mole phenomenon occurs as an active filter or passive filter installed on the long feeder line. It effect harmonic voltage where increase on some busses and decrease on other busses, especially at point of installation. In this paper, the inverter replaced by directly connected with the current source. Thus, parallels current source with combination of fundamental, third, fifth and seventh harmonic frequencies were tested. From the analysis, the best location of inverter current source should be at least lambda/4 from end bus. Thus, it proves by looking into its harmonic voltage, harmonic current and total harmonics distortion (THD) performance |
format |
Conference or Workshop Item |
author |
Aziah, Khamis Matthew, Armstrong Marizan, Sulaiman |
author_facet |
Aziah, Khamis Matthew, Armstrong Marizan, Sulaiman |
author_sort |
Aziah, Khamis |
title |
The impact of embedded generation due to harmonic performance |
title_short |
The impact of embedded generation due to harmonic performance |
title_full |
The impact of embedded generation due to harmonic performance |
title_fullStr |
The impact of embedded generation due to harmonic performance |
title_full_unstemmed |
The impact of embedded generation due to harmonic performance |
title_sort |
impact of embedded generation due to harmonic performance |
publishDate |
2009 |
url |
http://eprints.utem.edu.my/id/eprint/15162/1/The%20impact%20of%20embedded%20generation%20due%20to%20harmonic%20performance242.pdf http://eprints.utem.edu.my/id/eprint/15162/ |
_version_ |
1665905634163294208 |