Development Of Performance Standard For Circular Ducting Local Exhaust Ventilation System At Workplace

Engineering controls, such as local exhaust ventilation (LEV) system, are functioned to remove contaminants from work place, as it is vital that the level of contaminants must comply with legislation. Furthermore, LEV in industries has been designed, fabricated, and monitored to perform better in ac...

Full description

Saved in:
Bibliographic Details
Main Author: Hasan, Nor Halim
Format: Thesis
Language:English
English
Published: UTeM 2016
Subjects:
Online Access:http://eprints.utem.edu.my/id/eprint/18616/1/Development%20Of%20Performance%20Standard%20For%20Circular%20Ducting%20Local%20Exhaust%20Ventilation%20System%20At%20Workplace%2024%20Pages.pdf
http://eprints.utem.edu.my/id/eprint/18616/2/Development%20Of%20Performance%20Standard%20For%20Circular%20Ducting%20Local%20Exhaust%20Ventilation%20System%20At%20Workplace.pdf
http://eprints.utem.edu.my/id/eprint/18616/
https://plh.utem.edu.my/cgi-bin/koha/opac-detail.pl?biblionumber=100421
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Universiti Teknikal Malaysia Melaka
Language: English
English
id my.utem.eprints.18616
record_format eprints
spelling my.utem.eprints.186162021-10-08T16:02:01Z http://eprints.utem.edu.my/id/eprint/18616/ Development Of Performance Standard For Circular Ducting Local Exhaust Ventilation System At Workplace Hasan, Nor Halim T Technology (General) TH Building construction Engineering controls, such as local exhaust ventilation (LEV) system, are functioned to remove contaminants from work place, as it is vital that the level of contaminants must comply with legislation. Furthermore, LEV in industries has been designed, fabricated, and monitored to perform better in accordance to the American Conference for Governmental Industrial Hygienists (ACGIH) standard and the Guideline on LEV provided by Department of Occupational Safety and Health (DOSH). This study on LEV had been depicted from the Industrial Hygiene Technician assessment report due to issues on the effectiveness of LEV to remove contaminants. That includes problem of assessing, measuring the fan area, as well as the material fabricated. Thus, the objective of the study was to identify the current compliance of the national law with regards to LEV system. Moreover, besides determining the usage of ducting in LEV by looking into the characteristics of the material using American Society for Testing and Materials (ASTM) standard, the performance of LEV system was tested, as suggested in the ACGIH standard, through design, construct, and measurement data. Three different models (in laboratory scale model) of LEV system were designed according to the ACGIH Standard, and tested to determine the relationship between analytical, experimental, and numerical analyses in this study. As for the three models, they were designed and fabricated to measure velocity and flow of air. Meanwhile, as for numerical analysis, computer simulation i.e. Ansys CFX, Engineering Simulation Software version 14.0 (Ansys 14.0) was used to simulate these three models for verification and comparison. A comparative study was conducted to retrieve analytical, experimental, and simulation results to justify the performances of LEV on different velocity and static pressure values. The results showed that there was insignificant difference between the values of velocity that were calculated, measured, and simulated. The average difference for velocity data was 8%. Static pressure for analytical and experimental results also portrayed insignificant difference compared to simulation that was mostly influenced by the mesh of variable setting. The outcome of the study was to produce the Malaysian Standard on LEV system design, fabrication, measurement, and maintenance. The development of LEV Malaysian Standard through Standard and Industrial Research Institute of Malaysia (SIRIM) Berhad that proposes the evaluation of LEV performance should be carried out before any LEV system is developed due to cost consideration, besides benefiting employees and employers for their safety and health, and in preventing occupational diseases in the future. UTeM 2016 Thesis NonPeerReviewed text en http://eprints.utem.edu.my/id/eprint/18616/1/Development%20Of%20Performance%20Standard%20For%20Circular%20Ducting%20Local%20Exhaust%20Ventilation%20System%20At%20Workplace%2024%20Pages.pdf text en http://eprints.utem.edu.my/id/eprint/18616/2/Development%20Of%20Performance%20Standard%20For%20Circular%20Ducting%20Local%20Exhaust%20Ventilation%20System%20At%20Workplace.pdf Hasan, Nor Halim (2016) Development Of Performance Standard For Circular Ducting Local Exhaust Ventilation System At Workplace. Doctoral thesis, Universiti Teknikal Malaysia Melaka. https://plh.utem.edu.my/cgi-bin/koha/opac-detail.pl?biblionumber=100421 HF5351.M34 2016
institution Universiti Teknikal Malaysia Melaka
building UTEM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Teknikal Malaysia Melaka
content_source UTEM Institutional Repository
url_provider http://eprints.utem.edu.my/
language English
English
topic T Technology (General)
TH Building construction
spellingShingle T Technology (General)
TH Building construction
Hasan, Nor Halim
Development Of Performance Standard For Circular Ducting Local Exhaust Ventilation System At Workplace
description Engineering controls, such as local exhaust ventilation (LEV) system, are functioned to remove contaminants from work place, as it is vital that the level of contaminants must comply with legislation. Furthermore, LEV in industries has been designed, fabricated, and monitored to perform better in accordance to the American Conference for Governmental Industrial Hygienists (ACGIH) standard and the Guideline on LEV provided by Department of Occupational Safety and Health (DOSH). This study on LEV had been depicted from the Industrial Hygiene Technician assessment report due to issues on the effectiveness of LEV to remove contaminants. That includes problem of assessing, measuring the fan area, as well as the material fabricated. Thus, the objective of the study was to identify the current compliance of the national law with regards to LEV system. Moreover, besides determining the usage of ducting in LEV by looking into the characteristics of the material using American Society for Testing and Materials (ASTM) standard, the performance of LEV system was tested, as suggested in the ACGIH standard, through design, construct, and measurement data. Three different models (in laboratory scale model) of LEV system were designed according to the ACGIH Standard, and tested to determine the relationship between analytical, experimental, and numerical analyses in this study. As for the three models, they were designed and fabricated to measure velocity and flow of air. Meanwhile, as for numerical analysis, computer simulation i.e. Ansys CFX, Engineering Simulation Software version 14.0 (Ansys 14.0) was used to simulate these three models for verification and comparison. A comparative study was conducted to retrieve analytical, experimental, and simulation results to justify the performances of LEV on different velocity and static pressure values. The results showed that there was insignificant difference between the values of velocity that were calculated, measured, and simulated. The average difference for velocity data was 8%. Static pressure for analytical and experimental results also portrayed insignificant difference compared to simulation that was mostly influenced by the mesh of variable setting. The outcome of the study was to produce the Malaysian Standard on LEV system design, fabrication, measurement, and maintenance. The development of LEV Malaysian Standard through Standard and Industrial Research Institute of Malaysia (SIRIM) Berhad that proposes the evaluation of LEV performance should be carried out before any LEV system is developed due to cost consideration, besides benefiting employees and employers for their safety and health, and in preventing occupational diseases in the future.
format Thesis
author Hasan, Nor Halim
author_facet Hasan, Nor Halim
author_sort Hasan, Nor Halim
title Development Of Performance Standard For Circular Ducting Local Exhaust Ventilation System At Workplace
title_short Development Of Performance Standard For Circular Ducting Local Exhaust Ventilation System At Workplace
title_full Development Of Performance Standard For Circular Ducting Local Exhaust Ventilation System At Workplace
title_fullStr Development Of Performance Standard For Circular Ducting Local Exhaust Ventilation System At Workplace
title_full_unstemmed Development Of Performance Standard For Circular Ducting Local Exhaust Ventilation System At Workplace
title_sort development of performance standard for circular ducting local exhaust ventilation system at workplace
publisher UTeM
publishDate 2016
url http://eprints.utem.edu.my/id/eprint/18616/1/Development%20Of%20Performance%20Standard%20For%20Circular%20Ducting%20Local%20Exhaust%20Ventilation%20System%20At%20Workplace%2024%20Pages.pdf
http://eprints.utem.edu.my/id/eprint/18616/2/Development%20Of%20Performance%20Standard%20For%20Circular%20Ducting%20Local%20Exhaust%20Ventilation%20System%20At%20Workplace.pdf
http://eprints.utem.edu.my/id/eprint/18616/
https://plh.utem.edu.my/cgi-bin/koha/opac-detail.pl?biblionumber=100421
_version_ 1715193902705672192