The comparative study between twisted and non-twisted distribution line for photovoltaic system subjected to induced voltage generated by impulse voltage

The recent advancement of renewable energy sources and specifically photovoltaic system has resulted in outdoor installations of large power stations. A photovoltaic system is exposed to extreme ambient conditions due to the lightning strike activity that generated induced overvoltage which have a h...

Full description

Saved in:
Bibliographic Details
Main Authors: Abdul Rahim , Nur Hidayu, Baharudin, Zikri Abadi, Othman, Md Nazri, Ab Rahman, Puteri Nur Suhaila
Format: Article
Language:English
Published: Universitas Ahmad Dahlan (UAD) and Institute of Advanced Engineering and Science (IAES) 2014
Subjects:
Online Access:http://eprints.utem.edu.my/id/eprint/19287/2/The%20Comparative%20Study%20between%20Twisted%20and%20Non-Twisted%20for%20PV.pdf
http://eprints.utem.edu.my/id/eprint/19287/
http://www.iaesjournal.com/online/index.php/IJEECS/article/view/6275
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Universiti Teknikal Malaysia Melaka
Language: English
id my.utem.eprints.19287
record_format eprints
spelling my.utem.eprints.192872023-08-16T11:47:11Z http://eprints.utem.edu.my/id/eprint/19287/ The comparative study between twisted and non-twisted distribution line for photovoltaic system subjected to induced voltage generated by impulse voltage Abdul Rahim , Nur Hidayu Baharudin, Zikri Abadi Othman, Md Nazri Ab Rahman, Puteri Nur Suhaila T Technology (General) TK Electrical engineering. Electronics Nuclear engineering The recent advancement of renewable energy sources and specifically photovoltaic system has resulted in outdoor installations of large power stations. A photovoltaic system is exposed to extreme ambient conditions due to the lightning strike activity that generated induced overvoltage which have a high tendency to affect the electrical apparatus especially renewable energy plant that directly exposed to this source. This study is performed through experimental work by comparing the effect of induced overvoltage propagation upon between the twisted and non-twisted distribution line for photovoltaic system. The induced voltage is performed by using lightning impulse generator. It is found that the maximum voltage of the unwanted signal is proportional with the distant of the specimen. The closer distant between solar panel material and spark discharge, the more serious effect would occur due to the induced overvoltage. Universitas Ahmad Dahlan (UAD) and Institute of Advanced Engineering and Science (IAES) 2014-08 Article PeerReviewed text en http://eprints.utem.edu.my/id/eprint/19287/2/The%20Comparative%20Study%20between%20Twisted%20and%20Non-Twisted%20for%20PV.pdf Abdul Rahim , Nur Hidayu and Baharudin, Zikri Abadi and Othman, Md Nazri and Ab Rahman, Puteri Nur Suhaila (2014) The comparative study between twisted and non-twisted distribution line for photovoltaic system subjected to induced voltage generated by impulse voltage. TELKOMNIKA: Telecommunication, Computing, Electronics and Control, 12 (8). pp. 5774-5778. ISSN 1693-6930 http://www.iaesjournal.com/online/index.php/IJEECS/article/view/6275 10.11591/telkomnika.v12i8.6275
institution Universiti Teknikal Malaysia Melaka
building UTEM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Teknikal Malaysia Melaka
content_source UTEM Institutional Repository
url_provider http://eprints.utem.edu.my/
language English
topic T Technology (General)
TK Electrical engineering. Electronics Nuclear engineering
spellingShingle T Technology (General)
TK Electrical engineering. Electronics Nuclear engineering
Abdul Rahim , Nur Hidayu
Baharudin, Zikri Abadi
Othman, Md Nazri
Ab Rahman, Puteri Nur Suhaila
The comparative study between twisted and non-twisted distribution line for photovoltaic system subjected to induced voltage generated by impulse voltage
description The recent advancement of renewable energy sources and specifically photovoltaic system has resulted in outdoor installations of large power stations. A photovoltaic system is exposed to extreme ambient conditions due to the lightning strike activity that generated induced overvoltage which have a high tendency to affect the electrical apparatus especially renewable energy plant that directly exposed to this source. This study is performed through experimental work by comparing the effect of induced overvoltage propagation upon between the twisted and non-twisted distribution line for photovoltaic system. The induced voltage is performed by using lightning impulse generator. It is found that the maximum voltage of the unwanted signal is proportional with the distant of the specimen. The closer distant between solar panel material and spark discharge, the more serious effect would occur due to the induced overvoltage.
format Article
author Abdul Rahim , Nur Hidayu
Baharudin, Zikri Abadi
Othman, Md Nazri
Ab Rahman, Puteri Nur Suhaila
author_facet Abdul Rahim , Nur Hidayu
Baharudin, Zikri Abadi
Othman, Md Nazri
Ab Rahman, Puteri Nur Suhaila
author_sort Abdul Rahim , Nur Hidayu
title The comparative study between twisted and non-twisted distribution line for photovoltaic system subjected to induced voltage generated by impulse voltage
title_short The comparative study between twisted and non-twisted distribution line for photovoltaic system subjected to induced voltage generated by impulse voltage
title_full The comparative study between twisted and non-twisted distribution line for photovoltaic system subjected to induced voltage generated by impulse voltage
title_fullStr The comparative study between twisted and non-twisted distribution line for photovoltaic system subjected to induced voltage generated by impulse voltage
title_full_unstemmed The comparative study between twisted and non-twisted distribution line for photovoltaic system subjected to induced voltage generated by impulse voltage
title_sort comparative study between twisted and non-twisted distribution line for photovoltaic system subjected to induced voltage generated by impulse voltage
publisher Universitas Ahmad Dahlan (UAD) and Institute of Advanced Engineering and Science (IAES)
publishDate 2014
url http://eprints.utem.edu.my/id/eprint/19287/2/The%20Comparative%20Study%20between%20Twisted%20and%20Non-Twisted%20for%20PV.pdf
http://eprints.utem.edu.my/id/eprint/19287/
http://www.iaesjournal.com/online/index.php/IJEECS/article/view/6275
_version_ 1775626880060227584