An Investigation Of Inertia Constant In Single Generator On Transient Analysis For An Isolated Electrical Network System

An isolated electrical network which fed by an independent generator for a low voltage system is considerable in remote and islandic areas. Although the network system has less complexity in term of system structure, its stability level is crucial due to frequency dynamical responses. An influence o...

Full description

Saved in:
Bibliographic Details
Main Authors: Jamri, Mohd Saifuzam, Kamarudin, Muhammad Nizam, Mohd Jamil, Mohd Luqman
Format: Article
Language:English
Published: Institute of Advanced Engineering and Science 2021
Online Access:http://eprints.utem.edu.my/id/eprint/25768/2/2NDAUTHOR.PAPER.2021.IJECS2.PDF
http://eprints.utem.edu.my/id/eprint/25768/
http://ijeecs.iaescore.com/index.php/IJEECS/article/view/25670/15359#
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Universiti Teknikal Malaysia Melaka
Language: English
id my.utem.eprints.25768
record_format eprints
spelling my.utem.eprints.257682022-03-17T10:18:15Z http://eprints.utem.edu.my/id/eprint/25768/ An Investigation Of Inertia Constant In Single Generator On Transient Analysis For An Isolated Electrical Network System Jamri, Mohd Saifuzam Kamarudin, Muhammad Nizam Mohd Jamil, Mohd Luqman An isolated electrical network which fed by an independent generator for a low voltage system is considerable in remote and islandic areas. Although the network system has less complexity in term of system structure, its stability level is crucial due to frequency dynamical responses. An influence of initial stability margin on frequency stability study during contingency situation is a thing rather than being ignored. Here the initial transient response inherently delivers important info such as system inertia and momentarily power deficit. In this paper, an investigation of transient stability responses under different inertia values is carried out. The investigation is carried out by modelling the isolated system in MATLAB/Simulink environment which consists of state-space mathematical equations. It is confirmed that the generator system inertia shapes the initial slope, speed droop and oscillation. For a verification purpose, the influence of system inertia is also analyzed using bode diagram in which system gain and frequency margin are evaluated. Institute of Advanced Engineering and Science 2021-09 Article PeerReviewed text en http://eprints.utem.edu.my/id/eprint/25768/2/2NDAUTHOR.PAPER.2021.IJECS2.PDF Jamri, Mohd Saifuzam and Kamarudin, Muhammad Nizam and Mohd Jamil, Mohd Luqman (2021) An Investigation Of Inertia Constant In Single Generator On Transient Analysis For An Isolated Electrical Network System. Indonesian Journal of Electrical Engineering and Computer Science, 23 (3). pp. 1299-1305. ISSN 2502-4760 http://ijeecs.iaescore.com/index.php/IJEECS/article/view/25670/15359# 10.11591/ijeecs.v23.i3.pp1299-1305
institution Universiti Teknikal Malaysia Melaka
building UTEM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Teknikal Malaysia Melaka
content_source UTEM Institutional Repository
url_provider http://eprints.utem.edu.my/
language English
description An isolated electrical network which fed by an independent generator for a low voltage system is considerable in remote and islandic areas. Although the network system has less complexity in term of system structure, its stability level is crucial due to frequency dynamical responses. An influence of initial stability margin on frequency stability study during contingency situation is a thing rather than being ignored. Here the initial transient response inherently delivers important info such as system inertia and momentarily power deficit. In this paper, an investigation of transient stability responses under different inertia values is carried out. The investigation is carried out by modelling the isolated system in MATLAB/Simulink environment which consists of state-space mathematical equations. It is confirmed that the generator system inertia shapes the initial slope, speed droop and oscillation. For a verification purpose, the influence of system inertia is also analyzed using bode diagram in which system gain and frequency margin are evaluated.
format Article
author Jamri, Mohd Saifuzam
Kamarudin, Muhammad Nizam
Mohd Jamil, Mohd Luqman
spellingShingle Jamri, Mohd Saifuzam
Kamarudin, Muhammad Nizam
Mohd Jamil, Mohd Luqman
An Investigation Of Inertia Constant In Single Generator On Transient Analysis For An Isolated Electrical Network System
author_facet Jamri, Mohd Saifuzam
Kamarudin, Muhammad Nizam
Mohd Jamil, Mohd Luqman
author_sort Jamri, Mohd Saifuzam
title An Investigation Of Inertia Constant In Single Generator On Transient Analysis For An Isolated Electrical Network System
title_short An Investigation Of Inertia Constant In Single Generator On Transient Analysis For An Isolated Electrical Network System
title_full An Investigation Of Inertia Constant In Single Generator On Transient Analysis For An Isolated Electrical Network System
title_fullStr An Investigation Of Inertia Constant In Single Generator On Transient Analysis For An Isolated Electrical Network System
title_full_unstemmed An Investigation Of Inertia Constant In Single Generator On Transient Analysis For An Isolated Electrical Network System
title_sort investigation of inertia constant in single generator on transient analysis for an isolated electrical network system
publisher Institute of Advanced Engineering and Science
publishDate 2021
url http://eprints.utem.edu.my/id/eprint/25768/2/2NDAUTHOR.PAPER.2021.IJECS2.PDF
http://eprints.utem.edu.my/id/eprint/25768/
http://ijeecs.iaescore.com/index.php/IJEECS/article/view/25670/15359#
_version_ 1728055215100264448