A study of steady-state thermal distribution on circular plate using ANSYS
The purpose of this study is to investigate the thermal behavior of a circular-shaped hot plate when certain thermal load is applied. The hot plate is a part of hot surface deposition test equipment, and is placed on top of a heater block. The temperature distribution on the hot plate will indicate...
Saved in:
Main Authors: | , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Universiti Malaysia Perlis
2021
|
Online Access: | http://eprints.utem.edu.my/id/eprint/25906/2/VOL%2014%20SI%20AUG2021%20479-488.PDF http://eprints.utem.edu.my/id/eprint/25906/ https://ijneam.unimap.edu.my/images/PDF/IJNeaM%20Special%20Issue%202021%20(1)/Vol%2014%20SI%20Aug2021%20479-488.pdf |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Institution: | Universiti Teknikal Malaysia Melaka |
Language: | English |
id |
my.utem.eprints.25906 |
---|---|
record_format |
eprints |
spelling |
my.utem.eprints.259062022-05-06T09:45:02Z http://eprints.utem.edu.my/id/eprint/25906/ A study of steady-state thermal distribution on circular plate using ANSYS Akop, Mohd Zaid Jikol, Favian Salim, Mohd Azli Mohamed Arifin, Yusmady The purpose of this study is to investigate the thermal behavior of a circular-shaped hot plate when certain thermal load is applied. The hot plate is a part of hot surface deposition test equipment, and is placed on top of a heater block. The temperature distribution on the hot plate will indicate the highest temperature, and whether the temperature generated is as per required in the hot surface deposition test. Modelling of the heater block and the steady-state thermal analysis is conducted experimentally using ANSYS Release 16.2 software. The maximum temperature of the hot plate is compared to the applied temperature on the heater block. It is shown that there is dissimilarity of temperature between the hottest spot on the hot plate surface and the temperature applied. When conducting the real deposition test, the exact required temperature of the hot plate can be obtained by altering the temperature setting and measured accurately by using thermometer Universiti Malaysia Perlis 2021-08 Article PeerReviewed text en http://eprints.utem.edu.my/id/eprint/25906/2/VOL%2014%20SI%20AUG2021%20479-488.PDF Akop, Mohd Zaid and Jikol, Favian and Salim, Mohd Azli and Mohamed Arifin, Yusmady (2021) A study of steady-state thermal distribution on circular plate using ANSYS. International Journal of Nanoelectronics and Materials, 14 (SI). pp. 479-488. ISSN 1985-5761 https://ijneam.unimap.edu.my/images/PDF/IJNeaM%20Special%20Issue%202021%20(1)/Vol%2014%20SI%20Aug2021%20479-488.pdf |
institution |
Universiti Teknikal Malaysia Melaka |
building |
UTEM Library |
collection |
Institutional Repository |
continent |
Asia |
country |
Malaysia |
content_provider |
Universiti Teknikal Malaysia Melaka |
content_source |
UTEM Institutional Repository |
url_provider |
http://eprints.utem.edu.my/ |
language |
English |
description |
The purpose of this study is to investigate the thermal behavior of a circular-shaped hot plate when certain thermal load is applied. The hot plate is a part of hot surface deposition test equipment, and is placed on top of a heater block. The temperature distribution on the hot plate will indicate the highest temperature, and whether the temperature generated is as per required in the hot surface deposition test. Modelling of the heater block and the steady-state thermal analysis is conducted experimentally using ANSYS Release 16.2 software. The maximum temperature of the hot plate is compared to the applied temperature on the heater block. It is shown that there is dissimilarity of temperature between the hottest spot on the hot plate surface and the temperature applied. When conducting the real deposition test, the exact required temperature of the hot plate can be obtained by altering the temperature setting and measured accurately by using thermometer |
format |
Article |
author |
Akop, Mohd Zaid Jikol, Favian Salim, Mohd Azli Mohamed Arifin, Yusmady |
spellingShingle |
Akop, Mohd Zaid Jikol, Favian Salim, Mohd Azli Mohamed Arifin, Yusmady A study of steady-state thermal distribution on circular plate using ANSYS |
author_facet |
Akop, Mohd Zaid Jikol, Favian Salim, Mohd Azli Mohamed Arifin, Yusmady |
author_sort |
Akop, Mohd Zaid |
title |
A study of steady-state thermal distribution on circular plate using ANSYS |
title_short |
A study of steady-state thermal distribution on circular plate using ANSYS |
title_full |
A study of steady-state thermal distribution on circular plate using ANSYS |
title_fullStr |
A study of steady-state thermal distribution on circular plate using ANSYS |
title_full_unstemmed |
A study of steady-state thermal distribution on circular plate using ANSYS |
title_sort |
study of steady-state thermal distribution on circular plate using ansys |
publisher |
Universiti Malaysia Perlis |
publishDate |
2021 |
url |
http://eprints.utem.edu.my/id/eprint/25906/2/VOL%2014%20SI%20AUG2021%20479-488.PDF http://eprints.utem.edu.my/id/eprint/25906/ https://ijneam.unimap.edu.my/images/PDF/IJNeaM%20Special%20Issue%202021%20(1)/Vol%2014%20SI%20Aug2021%20479-488.pdf |
_version_ |
1732948770135474176 |