High Impedance Fault Detection on Power Distribution Feeder

This paper presents an intelligent algorithm using a Takagi Sugeno-Kang (TSK) fuzzy modeling approach based on subtractive clustering to detect high impedance fault. High impedance fault (HIF) is abnormal event on electric power distribution feeder which does not draw enough fault current to be dete...

Full description

Saved in:
Bibliographic Details
Main Authors: Sulaiman , Marizan, Tawafan, Adnan, Ibrahim, Zulkifilie
Format: Article
Language:English
Published: Praise Worthy Prize 2012
Subjects:
Online Access:http://eprints.utem.edu.my/id/eprint/9098/1/marizan%238.pdf
http://eprints.utem.edu.my/id/eprint/9098/
http://connection.ebscohost.com/c/articles/85324325/high-impedance-fault-detection-power-distribution-feeder
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Universiti Teknikal Malaysia Melaka
Language: English
id my.utem.eprints.9098
record_format eprints
spelling my.utem.eprints.90982015-05-28T04:01:27Z http://eprints.utem.edu.my/id/eprint/9098/ High Impedance Fault Detection on Power Distribution Feeder Sulaiman , Marizan Tawafan, Adnan Ibrahim, Zulkifilie TK Electrical engineering. Electronics Nuclear engineering This paper presents an intelligent algorithm using a Takagi Sugeno-Kang (TSK) fuzzy modeling approach based on subtractive clustering to detect high impedance fault. High impedance fault (HIF) is abnormal event on electric power distribution feeder which does not draw enough fault current to be detected by conventional protective devices. The algorithm for HIF detection based on the amplitude ratio of second and (3rd, 5th, 7th, 9th, 11th) harmonics to fundamental is presented. Fast Fourier Transformation (FFT) is used to extract the feature of the fault signal and other power system events. The effect of capacitor banks switching, non-linear load current, no-load line switching and other normal event on distribution feeder harmonics is discussed. HIF and other operation event data were obtained by simulation of a 13.8 kV distribution feeder using PSCAD. The results show that the proposed algorithm can distinguish successfully HIFs from other events in distribution power system. Praise Worthy Prize 2012-10 Article PeerReviewed application/pdf en http://eprints.utem.edu.my/id/eprint/9098/1/marizan%238.pdf Sulaiman , Marizan and Tawafan, Adnan and Ibrahim, Zulkifilie (2012) High Impedance Fault Detection on Power Distribution Feeder. International Review on Modelling & Simulations, 5 (5 Part). pp. 2197-2204. ISSN 1974-9821 http://connection.ebscohost.com/c/articles/85324325/high-impedance-fault-detection-power-distribution-feeder
institution Universiti Teknikal Malaysia Melaka
building UTEM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Teknikal Malaysia Melaka
content_source UTEM Institutional Repository
url_provider http://eprints.utem.edu.my/
language English
topic TK Electrical engineering. Electronics Nuclear engineering
spellingShingle TK Electrical engineering. Electronics Nuclear engineering
Sulaiman , Marizan
Tawafan, Adnan
Ibrahim, Zulkifilie
High Impedance Fault Detection on Power Distribution Feeder
description This paper presents an intelligent algorithm using a Takagi Sugeno-Kang (TSK) fuzzy modeling approach based on subtractive clustering to detect high impedance fault. High impedance fault (HIF) is abnormal event on electric power distribution feeder which does not draw enough fault current to be detected by conventional protective devices. The algorithm for HIF detection based on the amplitude ratio of second and (3rd, 5th, 7th, 9th, 11th) harmonics to fundamental is presented. Fast Fourier Transformation (FFT) is used to extract the feature of the fault signal and other power system events. The effect of capacitor banks switching, non-linear load current, no-load line switching and other normal event on distribution feeder harmonics is discussed. HIF and other operation event data were obtained by simulation of a 13.8 kV distribution feeder using PSCAD. The results show that the proposed algorithm can distinguish successfully HIFs from other events in distribution power system.
format Article
author Sulaiman , Marizan
Tawafan, Adnan
Ibrahim, Zulkifilie
author_facet Sulaiman , Marizan
Tawafan, Adnan
Ibrahim, Zulkifilie
author_sort Sulaiman , Marizan
title High Impedance Fault Detection on Power Distribution Feeder
title_short High Impedance Fault Detection on Power Distribution Feeder
title_full High Impedance Fault Detection on Power Distribution Feeder
title_fullStr High Impedance Fault Detection on Power Distribution Feeder
title_full_unstemmed High Impedance Fault Detection on Power Distribution Feeder
title_sort high impedance fault detection on power distribution feeder
publisher Praise Worthy Prize
publishDate 2012
url http://eprints.utem.edu.my/id/eprint/9098/1/marizan%238.pdf
http://eprints.utem.edu.my/id/eprint/9098/
http://connection.ebscohost.com/c/articles/85324325/high-impedance-fault-detection-power-distribution-feeder
_version_ 1665905385663365120