Thermal Performance of Horizontal Fixed Sun Shading Device

Earlier investigations on passive cooling methods applied software modelling, and the findings were not confirmed through field measurement. Hence, this study applied a stationary experiment on a real structure and weather conditions employing horizontal sun shading (SDH). The purpose of this study...

Full description

Saved in:
Bibliographic Details
Main Authors: Mohd Fadlullah Gimat, Mohd Fadlullah Gimat, Mohd Khairul Azhar Mat Sulaiman, Mohd Khairul Azhar Mat Sulaiman, Mohd Iskandar Abd Malek, Mohd Iskandar Abd Malek, Mohd Farihan Irfan Mohd Nor, Mohd Farihan Irfan Mohd Nor
Format: Article
Language:English
Published: uthm 2023
Subjects:
Online Access:http://eprints.uthm.edu.my/10525/1/J16175_72452410e5752701e13c5650c07b2a0a.pdf
http://eprints.uthm.edu.my/10525/
https://doi.org/10.30880/ijscet.2023.14.02.021
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Universiti Tun Hussein Onn Malaysia
Language: English
id my.uthm.eprints.10525
record_format eprints
spelling my.uthm.eprints.105252024-01-03T01:34:58Z http://eprints.uthm.edu.my/10525/ Thermal Performance of Horizontal Fixed Sun Shading Device Mohd Fadlullah Gimat, Mohd Fadlullah Gimat Mohd Khairul Azhar Mat Sulaiman, Mohd Khairul Azhar Mat Sulaiman Mohd Iskandar Abd Malek, Mohd Iskandar Abd Malek Mohd Farihan Irfan Mohd Nor, Mohd Farihan Irfan Mohd Nor T Technology (General) Earlier investigations on passive cooling methods applied software modelling, and the findings were not confirmed through field measurement. Hence, this study applied a stationary experiment on a real structure and weather conditions employing horizontal sun shading (SDH). The purpose of this study was to compare the performance of fixed passive sun-shading devices put on to the bare façade of three-story terrace shophouses in Malaysia. The experiment findings revealed that SDH significantly improved the internal thermal environment by lowering the average monthly indoor air temperature (Ta) by 0.98 K and the peak temperature by 2.11 K. SDH is also effective during the warmest sunny days, lowering 1.23 K on average for the day. Meanwhile, SDH reduced the temperature in the control room by 5.40 K during the warmest peak time. When it came to indoor mean radiant temperature (Tmrt), SDH performed better than the control room in the very hot peak over a month (2.38 K) and on the highest temperature of the day (7.70 K). Finally, it can be inferred that SDH worked better from late at night until early in the morning, cooling the room temperature faster. This quiescent choice is one of the best for enhancing a building's internal thermal performance while also possibly contributing to a decrease in operational energy consumption. uthm 2023 Article PeerReviewed text en http://eprints.uthm.edu.my/10525/1/J16175_72452410e5752701e13c5650c07b2a0a.pdf Mohd Fadlullah Gimat, Mohd Fadlullah Gimat and Mohd Khairul Azhar Mat Sulaiman, Mohd Khairul Azhar Mat Sulaiman and Mohd Iskandar Abd Malek, Mohd Iskandar Abd Malek and Mohd Farihan Irfan Mohd Nor, Mohd Farihan Irfan Mohd Nor (2023) Thermal Performance of Horizontal Fixed Sun Shading Device. INTERNATIONAL JOURNAL OF SUSTAINABLE CONSTRUCTION ENGINEERING AND TECHNOLOGY, 14 (2). pp. 205-213. ISSN 2180-3242 https://doi.org/10.30880/ijscet.2023.14.02.021
institution Universiti Tun Hussein Onn Malaysia
building UTHM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Tun Hussein Onn Malaysia
content_source UTHM Institutional Repository
url_provider http://eprints.uthm.edu.my/
language English
topic T Technology (General)
spellingShingle T Technology (General)
Mohd Fadlullah Gimat, Mohd Fadlullah Gimat
Mohd Khairul Azhar Mat Sulaiman, Mohd Khairul Azhar Mat Sulaiman
Mohd Iskandar Abd Malek, Mohd Iskandar Abd Malek
Mohd Farihan Irfan Mohd Nor, Mohd Farihan Irfan Mohd Nor
Thermal Performance of Horizontal Fixed Sun Shading Device
description Earlier investigations on passive cooling methods applied software modelling, and the findings were not confirmed through field measurement. Hence, this study applied a stationary experiment on a real structure and weather conditions employing horizontal sun shading (SDH). The purpose of this study was to compare the performance of fixed passive sun-shading devices put on to the bare façade of three-story terrace shophouses in Malaysia. The experiment findings revealed that SDH significantly improved the internal thermal environment by lowering the average monthly indoor air temperature (Ta) by 0.98 K and the peak temperature by 2.11 K. SDH is also effective during the warmest sunny days, lowering 1.23 K on average for the day. Meanwhile, SDH reduced the temperature in the control room by 5.40 K during the warmest peak time. When it came to indoor mean radiant temperature (Tmrt), SDH performed better than the control room in the very hot peak over a month (2.38 K) and on the highest temperature of the day (7.70 K). Finally, it can be inferred that SDH worked better from late at night until early in the morning, cooling the room temperature faster. This quiescent choice is one of the best for enhancing a building's internal thermal performance while also possibly contributing to a decrease in operational energy consumption.
format Article
author Mohd Fadlullah Gimat, Mohd Fadlullah Gimat
Mohd Khairul Azhar Mat Sulaiman, Mohd Khairul Azhar Mat Sulaiman
Mohd Iskandar Abd Malek, Mohd Iskandar Abd Malek
Mohd Farihan Irfan Mohd Nor, Mohd Farihan Irfan Mohd Nor
author_facet Mohd Fadlullah Gimat, Mohd Fadlullah Gimat
Mohd Khairul Azhar Mat Sulaiman, Mohd Khairul Azhar Mat Sulaiman
Mohd Iskandar Abd Malek, Mohd Iskandar Abd Malek
Mohd Farihan Irfan Mohd Nor, Mohd Farihan Irfan Mohd Nor
author_sort Mohd Fadlullah Gimat, Mohd Fadlullah Gimat
title Thermal Performance of Horizontal Fixed Sun Shading Device
title_short Thermal Performance of Horizontal Fixed Sun Shading Device
title_full Thermal Performance of Horizontal Fixed Sun Shading Device
title_fullStr Thermal Performance of Horizontal Fixed Sun Shading Device
title_full_unstemmed Thermal Performance of Horizontal Fixed Sun Shading Device
title_sort thermal performance of horizontal fixed sun shading device
publisher uthm
publishDate 2023
url http://eprints.uthm.edu.my/10525/1/J16175_72452410e5752701e13c5650c07b2a0a.pdf
http://eprints.uthm.edu.my/10525/
https://doi.org/10.30880/ijscet.2023.14.02.021
_version_ 1787137848759025664