Experimental and analytical study of pvc confined concrete cylinders

This study presents results of an experimental research on the concrete filled Poly Vinyl Chloride (PVC) tubes short columns with various typical strengths of the infill concrete; C20, C25, C40. A total of 36 Concrete Filled Tube columns using PVC tubes (CFT PVC) were tested to investigate the colum...

Full description

Saved in:
Bibliographic Details
Main Authors: Abdulrazzaq Azeez, Alyaa, Jamaluddin, Norwati, Abd Rahman, Norashidah, Hassen, Douread Raheem, Attiyah, Ali Naji
Format: Article
Language:English
Published: Medwell Journals 2018
Subjects:
Online Access:http://eprints.uthm.edu.my/4249/1/AJ%202018%20%28409%29.pdf
http://eprints.uthm.edu.my/4249/
https://doi.org/10.36478/jeasci.2018.2145.2151
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Universiti Tun Hussein Onn Malaysia
Language: English
Description
Summary:This study presents results of an experimental research on the concrete filled Poly Vinyl Chloride (PVC) tubes short columns with various typical strengths of the infill concrete; C20, C25, C40. A total of 36 Concrete Filled Tube columns using PVC tubes (CFT PVC) were tested to investigate the column’s behaviour and 18 cylinder concrete column. The columns are 200 mm height, 100 mm external diameter and 3.5 and 4.8 mm tube thickness. The results presented include the maximum axial load, thickness effect, the mode of failure and concrete compressive strength effect. The column resistance shows an increment of between 32.24-83.25% higher compared to the control column specimens. The design equations for the CFT PVC tube columns are proposed.