Hardware development of electrical capacitance tomography for imaging a mixture of water and oil
This paper proposes the process of investigating the changes of capacitance value due to the changes of permittivity distribution of a different dielectric materials such as water and oil in a conveying pipeline using twelve externally Electrical Capacitance Tomography (ECT) sensor. Electrical capa...
Saved in:
Main Authors: | , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Penerbit UTM Press
2011
|
Subjects: | |
Online Access: | http://eprints.uthm.edu.my/4365/1/AJ%202017%20%28138%29%20Hardware%20development%20of%20electrical%20capacitance%20tomography%20for%20imaging.pdf http://eprints.uthm.edu.my/4365/ |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Institution: | Universiti Tun Hussein Onn Malaysia |
Language: | English |
id |
my.uthm.eprints.4365 |
---|---|
record_format |
eprints |
spelling |
my.uthm.eprints.43652021-12-02T03:45:27Z http://eprints.uthm.edu.my/4365/ Hardware development of electrical capacitance tomography for imaging a mixture of water and oil Mohamad, Elmy Johana Mohd Yunus, Fazlul Rahman Abdul Rahim, Ruzairi Chan, Kok Seong TK Electrical engineering. Electronics Nuclear engineering TA1501-1820 Applied optics. Photonics TK7800-8360 Electronics This paper proposes the process of investigating the changes of capacitance value due to the changes of permittivity distribution of a different dielectric materials such as water and oil in a conveying pipeline using twelve externally Electrical Capacitance Tomography (ECT) sensor. Electrical capacitance tomography system is a system which can be used for imaging industrial multi-component processes involving non-conducting fluids in pipeline. Therefore, in this research, a 12 electrodes electrical capacitance tomography system is developed. This system can provide more data for processing to obtain more precise images of the pipeline. In order to reduce the noise in the system, on-plate signal conditioning board is applied in this research to eliminate certain noise source from the analogue transmission line. Then, various of ac capacitance measuring circuits has been developed in terms of performance and sensitivity to achieve low noise level, wide dynamic range and high immunity stray capacitance to suits the appropriate design for system development. The signal produced by the detection circuit is digitized by using multiplexing circuit, ADC circuit and buffering so that the transferring data is suitable for pc interface. A graphic user interface (GUI) is developed with visible controls and indicators to provide users with organized interactive panels. Penerbit UTM Press 2011 Article PeerReviewed text en http://eprints.uthm.edu.my/4365/1/AJ%202017%20%28138%29%20Hardware%20development%20of%20electrical%20capacitance%20tomography%20for%20imaging.pdf Mohamad, Elmy Johana and Mohd Yunus, Fazlul Rahman and Abdul Rahim, Ruzairi and Chan, Kok Seong (2011) Hardware development of electrical capacitance tomography for imaging a mixture of water and oil. Jurnal Teknologi, 54. pp. 425-442. ISSN 0127-9696 |
institution |
Universiti Tun Hussein Onn Malaysia |
building |
UTHM Library |
collection |
Institutional Repository |
continent |
Asia |
country |
Malaysia |
content_provider |
Universiti Tun Hussein Onn Malaysia |
content_source |
UTHM Institutional Repository |
url_provider |
http://eprints.uthm.edu.my/ |
language |
English |
topic |
TK Electrical engineering. Electronics Nuclear engineering TA1501-1820 Applied optics. Photonics TK7800-8360 Electronics |
spellingShingle |
TK Electrical engineering. Electronics Nuclear engineering TA1501-1820 Applied optics. Photonics TK7800-8360 Electronics Mohamad, Elmy Johana Mohd Yunus, Fazlul Rahman Abdul Rahim, Ruzairi Chan, Kok Seong Hardware development of electrical capacitance tomography for imaging a mixture of water and oil |
description |
This paper proposes the process of investigating the changes of capacitance value due to the changes of permittivity distribution of a different dielectric materials such as water and oil in a conveying pipeline using twelve externally Electrical Capacitance Tomography (ECT) sensor. Electrical capacitance tomography system is a system which can be used for imaging industrial multi-component processes involving non-conducting fluids in pipeline. Therefore, in this research, a 12 electrodes electrical capacitance tomography system is developed. This system can provide more data for processing to obtain more precise images of the pipeline. In order to reduce the noise in the system, on-plate signal conditioning board is applied in this research to eliminate certain noise source from the analogue transmission line. Then, various of ac capacitance measuring circuits has been developed in terms of performance and sensitivity to achieve low noise level, wide dynamic range and high immunity stray capacitance to suits the appropriate design for system development. The signal produced by the detection circuit is digitized by using multiplexing circuit, ADC circuit and buffering so that the transferring data is suitable for pc interface. A graphic user interface (GUI) is developed with visible controls and indicators to provide users with organized interactive panels. |
format |
Article |
author |
Mohamad, Elmy Johana Mohd Yunus, Fazlul Rahman Abdul Rahim, Ruzairi Chan, Kok Seong |
author_facet |
Mohamad, Elmy Johana Mohd Yunus, Fazlul Rahman Abdul Rahim, Ruzairi Chan, Kok Seong |
author_sort |
Mohamad, Elmy Johana |
title |
Hardware development of electrical capacitance tomography for imaging a mixture of water and oil |
title_short |
Hardware development of electrical capacitance tomography for imaging a mixture of water and oil |
title_full |
Hardware development of electrical capacitance tomography for imaging a mixture of water and oil |
title_fullStr |
Hardware development of electrical capacitance tomography for imaging a mixture of water and oil |
title_full_unstemmed |
Hardware development of electrical capacitance tomography for imaging a mixture of water and oil |
title_sort |
hardware development of electrical capacitance tomography for imaging a mixture of water and oil |
publisher |
Penerbit UTM Press |
publishDate |
2011 |
url |
http://eprints.uthm.edu.my/4365/1/AJ%202017%20%28138%29%20Hardware%20development%20of%20electrical%20capacitance%20tomography%20for%20imaging.pdf http://eprints.uthm.edu.my/4365/ |
_version_ |
1738581241832144896 |