Fundamental study of pulse electric field effects on hela cell cultured over extracellular matrix protein micro-patterned surface

Electroporation (EP) is a method of controlling cell function by using pulses of electrical fields to create pores through cell membrane and causes other substance around it to be absorbed into the cell. This method has led to a variety of medical applications, particularly in cell studies. In th...

Full description

Saved in:
Bibliographic Details
Main Author: Abd Rahman, Nur Adilah
Format: Thesis
Language:English
English
Published: 2017
Subjects:
Online Access:http://eprints.uthm.edu.my/845/1/24p%20NUR%20ADILAH%20ABD%20RAHMAN.pdf
http://eprints.uthm.edu.my/845/2/NUR%20ADILAH%20ABD%20RAHMAN%20WATERMARK.pdf
http://eprints.uthm.edu.my/845/
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Universiti Tun Hussein Onn Malaysia
Language: English
English
id my.uthm.eprints.845
record_format eprints
spelling my.uthm.eprints.8452021-09-06T04:22:19Z http://eprints.uthm.edu.my/845/ Fundamental study of pulse electric field effects on hela cell cultured over extracellular matrix protein micro-patterned surface Abd Rahman, Nur Adilah R Medicine (General) Electroporation (EP) is a method of controlling cell function by using pulses of electrical fields to create pores through cell membrane and causes other substance around it to be absorbed into the cell. This method has led to a variety of medical applications, particularly in cell studies. In this study, a high voltage of 2 kV/cm with pulse duration of 30 µs was applied on HeLa cell (human cervical cancer cell) to investigate the electroporation process. In addition, this study focused on the effect of protein coated surface, combined with the pulse parameter mentioned above, to look at its effect on HeLa cell when exposed to high voltage. Thus, will lead towards cell surface attachment factors interrogation plus the presence of electric field as the stimulator for an aggressive growth rate of the cells. This was achieved by using the micro contact printing (μCP) method. The result showed positive respond on the effect of EP on protein printed surface combination where HeLa cells were grown. The 50µm was chosen as the best-pattern size for cell alignment by using fibronectin. From the cell guidance study we could clearly see the cell responses on the protein patterned surface are much elongated in comparison to the control. In addition, the cells plated on this patterned surface were further investigated with electroporation technique, in order to see the effect of electroporation on the cancer cell proliferation and other cellular activities. The result shows that the cells aligned and elongated on fibronectin pattern with PEF than without PEF exposure. The combination of these two techniques will contribute towards understanding the cell surface interface and cell surface attachment factors which may lead towards a new method for guiding cell towards wound healing process. 2017-08 Thesis NonPeerReviewed text en http://eprints.uthm.edu.my/845/1/24p%20NUR%20ADILAH%20ABD%20RAHMAN.pdf text en http://eprints.uthm.edu.my/845/2/NUR%20ADILAH%20ABD%20RAHMAN%20WATERMARK.pdf Abd Rahman, Nur Adilah (2017) Fundamental study of pulse electric field effects on hela cell cultured over extracellular matrix protein micro-patterned surface. Masters thesis, Universiti Tun Hussein Onn Malaysia.
institution Universiti Tun Hussein Onn Malaysia
building UTHM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Tun Hussein Onn Malaysia
content_source UTHM Institutional Repository
url_provider http://eprints.uthm.edu.my/
language English
English
topic R Medicine (General)
spellingShingle R Medicine (General)
Abd Rahman, Nur Adilah
Fundamental study of pulse electric field effects on hela cell cultured over extracellular matrix protein micro-patterned surface
description Electroporation (EP) is a method of controlling cell function by using pulses of electrical fields to create pores through cell membrane and causes other substance around it to be absorbed into the cell. This method has led to a variety of medical applications, particularly in cell studies. In this study, a high voltage of 2 kV/cm with pulse duration of 30 µs was applied on HeLa cell (human cervical cancer cell) to investigate the electroporation process. In addition, this study focused on the effect of protein coated surface, combined with the pulse parameter mentioned above, to look at its effect on HeLa cell when exposed to high voltage. Thus, will lead towards cell surface attachment factors interrogation plus the presence of electric field as the stimulator for an aggressive growth rate of the cells. This was achieved by using the micro contact printing (μCP) method. The result showed positive respond on the effect of EP on protein printed surface combination where HeLa cells were grown. The 50µm was chosen as the best-pattern size for cell alignment by using fibronectin. From the cell guidance study we could clearly see the cell responses on the protein patterned surface are much elongated in comparison to the control. In addition, the cells plated on this patterned surface were further investigated with electroporation technique, in order to see the effect of electroporation on the cancer cell proliferation and other cellular activities. The result shows that the cells aligned and elongated on fibronectin pattern with PEF than without PEF exposure. The combination of these two techniques will contribute towards understanding the cell surface interface and cell surface attachment factors which may lead towards a new method for guiding cell towards wound healing process.
format Thesis
author Abd Rahman, Nur Adilah
author_facet Abd Rahman, Nur Adilah
author_sort Abd Rahman, Nur Adilah
title Fundamental study of pulse electric field effects on hela cell cultured over extracellular matrix protein micro-patterned surface
title_short Fundamental study of pulse electric field effects on hela cell cultured over extracellular matrix protein micro-patterned surface
title_full Fundamental study of pulse electric field effects on hela cell cultured over extracellular matrix protein micro-patterned surface
title_fullStr Fundamental study of pulse electric field effects on hela cell cultured over extracellular matrix protein micro-patterned surface
title_full_unstemmed Fundamental study of pulse electric field effects on hela cell cultured over extracellular matrix protein micro-patterned surface
title_sort fundamental study of pulse electric field effects on hela cell cultured over extracellular matrix protein micro-patterned surface
publishDate 2017
url http://eprints.uthm.edu.my/845/1/24p%20NUR%20ADILAH%20ABD%20RAHMAN.pdf
http://eprints.uthm.edu.my/845/2/NUR%20ADILAH%20ABD%20RAHMAN%20WATERMARK.pdf
http://eprints.uthm.edu.my/845/
_version_ 1738580789847654400