Cooling load prediction model during the design of mosques in Madinah

The building sector accounts for almost 40% of the total global energy consumption. Saudi Arabia, along with other developed countries have expressed their concern on the increasing energy demand and established several related policies focusing on the building sector. Mosques are one category of bu...

Full description

Saved in:
Bibliographic Details
Main Author: Alharbi, Emad Ameen
Format: Thesis
Language:English
Published: 2022
Subjects:
Online Access:http://eprints.utm.my/id/eprint/101472/1/EmadAmeenPSKA2022.pdf
http://eprints.utm.my/id/eprint/101472/
http://dms.library.utm.my:8080/vital/access/manager/Repository/vital:150564
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Universiti Teknologi Malaysia
Language: English
id my.utm.101472
record_format eprints
spelling my.utm.1014722023-06-21T09:51:10Z http://eprints.utm.my/id/eprint/101472/ Cooling load prediction model during the design of mosques in Madinah Alharbi, Emad Ameen TA Engineering (General). Civil engineering (General) The building sector accounts for almost 40% of the total global energy consumption. Saudi Arabia, along with other developed countries have expressed their concern on the increasing energy demand and established several related policies focusing on the building sector. Mosques are one category of buildings that consume huge amounts of energy above other public sector buildings such as hospitals. An extensive review of literature has revealed that there is an increased demand to build new mosques. The majority of previous research works focused on operational and maintenance stages. In term of energy reduction, not much can be done to existing mosques as the solutions are both costly and time consuming. The importance of making right design at the design stage has been stressed which may save up to 70% of total energy consumption. The literature also revealed that there is a gap and absence of design stage integration for mosque projects, due to the complexity of the stage, the lack of information, and limited support tools. This research aims to develop a prediction model known as the Mosque Cooling Load Prediction Model (MCLPM) to assist designers and local authorities in reducing the energy consumption of mosques during the design stage. The process began by identifying significant structural and architectural design parameters that influence the energy consumption of mosques, using a three rounds of Delphi approach with 33 local experts. Thirteen significant parameters were identified, of which mosque orientation was found to be the most significant. Integration between Rhinoceros/Grasshopper parametric model, EnergyPlus™ simulation of selected medium-sized mosques, and optimization through Genetic Algorithm (GA) and Galapagos were made to generate the dataset required for developing mosque cooling load prediction model based on the Artificial Neural Network (ANN) approach. Two thousand five hundred simulations were performed to achieve the optimum (approximately 58%) of total energy reduction, and 23 non-repetitive design alternatives with the least demand for cooling load were generated. The Mean Square Error (MSE) and correlation coefficient (R) were obtained for the developed ANN prediction model. Based on the findings, the least MSE and R values were at 6.27 * 1 0 _ 9 and 0.99888, respectively. Validation of the results revealed that the back-propagation strategy and Levenberg-Marquardt algorithm have the highest accuracies in predicting the exact total cooling load, in comparison to the actual values, and the absolute difference is less than 1%. The comparison with other methods and algorithms showed that the proposed prediction model has the highest accuracy, effectiveness, and least time required, to complete a given task. Hence, the developed prediction model act as a powerful tool to support the decision-making process that helps mosque designers provide a range of lowest cooling load design alternatives, thus facilitating the design process, and easy-quick estimation of total cooling load. 2022 Thesis NonPeerReviewed application/pdf en http://eprints.utm.my/id/eprint/101472/1/EmadAmeenPSKA2022.pdf Alharbi, Emad Ameen (2022) Cooling load prediction model during the design of mosques in Madinah. PhD thesis, Universiti Teknologi Malaysia. http://dms.library.utm.my:8080/vital/access/manager/Repository/vital:150564
institution Universiti Teknologi Malaysia
building UTM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Teknologi Malaysia
content_source UTM Institutional Repository
url_provider http://eprints.utm.my/
language English
topic TA Engineering (General). Civil engineering (General)
spellingShingle TA Engineering (General). Civil engineering (General)
Alharbi, Emad Ameen
Cooling load prediction model during the design of mosques in Madinah
description The building sector accounts for almost 40% of the total global energy consumption. Saudi Arabia, along with other developed countries have expressed their concern on the increasing energy demand and established several related policies focusing on the building sector. Mosques are one category of buildings that consume huge amounts of energy above other public sector buildings such as hospitals. An extensive review of literature has revealed that there is an increased demand to build new mosques. The majority of previous research works focused on operational and maintenance stages. In term of energy reduction, not much can be done to existing mosques as the solutions are both costly and time consuming. The importance of making right design at the design stage has been stressed which may save up to 70% of total energy consumption. The literature also revealed that there is a gap and absence of design stage integration for mosque projects, due to the complexity of the stage, the lack of information, and limited support tools. This research aims to develop a prediction model known as the Mosque Cooling Load Prediction Model (MCLPM) to assist designers and local authorities in reducing the energy consumption of mosques during the design stage. The process began by identifying significant structural and architectural design parameters that influence the energy consumption of mosques, using a three rounds of Delphi approach with 33 local experts. Thirteen significant parameters were identified, of which mosque orientation was found to be the most significant. Integration between Rhinoceros/Grasshopper parametric model, EnergyPlus™ simulation of selected medium-sized mosques, and optimization through Genetic Algorithm (GA) and Galapagos were made to generate the dataset required for developing mosque cooling load prediction model based on the Artificial Neural Network (ANN) approach. Two thousand five hundred simulations were performed to achieve the optimum (approximately 58%) of total energy reduction, and 23 non-repetitive design alternatives with the least demand for cooling load were generated. The Mean Square Error (MSE) and correlation coefficient (R) were obtained for the developed ANN prediction model. Based on the findings, the least MSE and R values were at 6.27 * 1 0 _ 9 and 0.99888, respectively. Validation of the results revealed that the back-propagation strategy and Levenberg-Marquardt algorithm have the highest accuracies in predicting the exact total cooling load, in comparison to the actual values, and the absolute difference is less than 1%. The comparison with other methods and algorithms showed that the proposed prediction model has the highest accuracy, effectiveness, and least time required, to complete a given task. Hence, the developed prediction model act as a powerful tool to support the decision-making process that helps mosque designers provide a range of lowest cooling load design alternatives, thus facilitating the design process, and easy-quick estimation of total cooling load.
format Thesis
author Alharbi, Emad Ameen
author_facet Alharbi, Emad Ameen
author_sort Alharbi, Emad Ameen
title Cooling load prediction model during the design of mosques in Madinah
title_short Cooling load prediction model during the design of mosques in Madinah
title_full Cooling load prediction model during the design of mosques in Madinah
title_fullStr Cooling load prediction model during the design of mosques in Madinah
title_full_unstemmed Cooling load prediction model during the design of mosques in Madinah
title_sort cooling load prediction model during the design of mosques in madinah
publishDate 2022
url http://eprints.utm.my/id/eprint/101472/1/EmadAmeenPSKA2022.pdf
http://eprints.utm.my/id/eprint/101472/
http://dms.library.utm.my:8080/vital/access/manager/Repository/vital:150564
_version_ 1769842060092768256