Seamless capable PV power generation system without battery storage for rural residential load

The presented system is a three-phase three-wire (3P–3W), seamless, capable, dual-stage PV power generation system without battery storage for rural residential loads to ensure a continuous power supply during the daytime. This system effortlessly shifts from the grid-connected (GC) mode to the stan...

Full description

Saved in:
Bibliographic Details
Main Authors: Chankaya, Mukul, Hussain, Ikhlaq, Malik, Hasmat, Ahmad, Aijaz, A. Alotaibi, Majed, GarcíaMárquez, Fausto Pedro
Format: Article
Language:English
Published: MDPI 2022
Subjects:
Online Access:http://eprints.utm.my/103603/1/Hasmat2022_SeamlessCapablePVPowerGeneration.pdf
http://eprints.utm.my/103603/
http://dx.doi.org/10.3390/electronics11152413
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Universiti Teknologi Malaysia
Language: English
id my.utm.103603
record_format eprints
spelling my.utm.1036032023-11-20T03:12:24Z http://eprints.utm.my/103603/ Seamless capable PV power generation system without battery storage for rural residential load Chankaya, Mukul Hussain, Ikhlaq Malik, Hasmat Ahmad, Aijaz A. Alotaibi, Majed GarcíaMárquez, Fausto Pedro TK Electrical engineering. Electronics Nuclear engineering The presented system is a three-phase three-wire (3P–3W), seamless, capable, dual-stage PV power generation system without battery storage for rural residential loads to ensure a continuous power supply during the daytime. This system effortlessly shifts from the grid-connected (GC) mode to the standalone (SA) mode when the grid utility is unavailable. During the GC mode, a voltage source converter (VSC) is regulated by the polynomial zero-attracting least mean square (PZA-LMS) algorithm-based current control scheme. During the GC mode, the power balance is achieved at the point of common coupling (PCC) by exchanging active power with the grid, whereas the VSC delivers reactive power. Considering the low efficiency of PV power generation systems, an incremental conductance (InC)-based maximum power point tracking (MPPT) algorithm is necessary for the maximum power extraction out of a PV array. During the unavailability of the grid, the presented system operates in the SA mode, when the load is delivered with PV power only via VSC. Considering the high cost of the battery storage system (BSS), bi-directional converter, and charge control circuitry incurred by rural consumers, they were omitted from the system. Without a BSS, the InC-based MPPT is executed in the derated mode, extracting the PV power to exactly match the load demand. Without derated PV power generation operation, the load may be damaged due to excess PV power flow to the load end or the load may remain underpowered, leading to load shedding or complete disconnection. A synchronous reference frame (SRF)-based voltage control scheme is responsible for the VSC control during the SA operation of the system. The presented system performance was observed and found satisfactory during the irradiation variation, load balancing, islanding, and re-synchronization of the grid. The presented system was found to carry out harmonics suppression and active and reactive power balance at the PCC during both the GC and SA modes. The grid’s total harmonics distortion (THD) levels were shown to be kept below 5% as per the IEEE 519 standard in the GC mode. MDPI 2022 Article PeerReviewed application/pdf en http://eprints.utm.my/103603/1/Hasmat2022_SeamlessCapablePVPowerGeneration.pdf Chankaya, Mukul and Hussain, Ikhlaq and Malik, Hasmat and Ahmad, Aijaz and A. Alotaibi, Majed and GarcíaMárquez, Fausto Pedro (2022) Seamless capable PV power generation system without battery storage for rural residential load. Electronics (Switzerland), 11 (15). pp. 1-19. ISSN 2079-9292 http://dx.doi.org/10.3390/electronics11152413 DOI : 10.3390/electronics11152413
institution Universiti Teknologi Malaysia
building UTM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Teknologi Malaysia
content_source UTM Institutional Repository
url_provider http://eprints.utm.my/
language English
topic TK Electrical engineering. Electronics Nuclear engineering
spellingShingle TK Electrical engineering. Electronics Nuclear engineering
Chankaya, Mukul
Hussain, Ikhlaq
Malik, Hasmat
Ahmad, Aijaz
A. Alotaibi, Majed
GarcíaMárquez, Fausto Pedro
Seamless capable PV power generation system without battery storage for rural residential load
description The presented system is a three-phase three-wire (3P–3W), seamless, capable, dual-stage PV power generation system without battery storage for rural residential loads to ensure a continuous power supply during the daytime. This system effortlessly shifts from the grid-connected (GC) mode to the standalone (SA) mode when the grid utility is unavailable. During the GC mode, a voltage source converter (VSC) is regulated by the polynomial zero-attracting least mean square (PZA-LMS) algorithm-based current control scheme. During the GC mode, the power balance is achieved at the point of common coupling (PCC) by exchanging active power with the grid, whereas the VSC delivers reactive power. Considering the low efficiency of PV power generation systems, an incremental conductance (InC)-based maximum power point tracking (MPPT) algorithm is necessary for the maximum power extraction out of a PV array. During the unavailability of the grid, the presented system operates in the SA mode, when the load is delivered with PV power only via VSC. Considering the high cost of the battery storage system (BSS), bi-directional converter, and charge control circuitry incurred by rural consumers, they were omitted from the system. Without a BSS, the InC-based MPPT is executed in the derated mode, extracting the PV power to exactly match the load demand. Without derated PV power generation operation, the load may be damaged due to excess PV power flow to the load end or the load may remain underpowered, leading to load shedding or complete disconnection. A synchronous reference frame (SRF)-based voltage control scheme is responsible for the VSC control during the SA operation of the system. The presented system performance was observed and found satisfactory during the irradiation variation, load balancing, islanding, and re-synchronization of the grid. The presented system was found to carry out harmonics suppression and active and reactive power balance at the PCC during both the GC and SA modes. The grid’s total harmonics distortion (THD) levels were shown to be kept below 5% as per the IEEE 519 standard in the GC mode.
format Article
author Chankaya, Mukul
Hussain, Ikhlaq
Malik, Hasmat
Ahmad, Aijaz
A. Alotaibi, Majed
GarcíaMárquez, Fausto Pedro
author_facet Chankaya, Mukul
Hussain, Ikhlaq
Malik, Hasmat
Ahmad, Aijaz
A. Alotaibi, Majed
GarcíaMárquez, Fausto Pedro
author_sort Chankaya, Mukul
title Seamless capable PV power generation system without battery storage for rural residential load
title_short Seamless capable PV power generation system without battery storage for rural residential load
title_full Seamless capable PV power generation system without battery storage for rural residential load
title_fullStr Seamless capable PV power generation system without battery storage for rural residential load
title_full_unstemmed Seamless capable PV power generation system without battery storage for rural residential load
title_sort seamless capable pv power generation system without battery storage for rural residential load
publisher MDPI
publishDate 2022
url http://eprints.utm.my/103603/1/Hasmat2022_SeamlessCapablePVPowerGeneration.pdf
http://eprints.utm.my/103603/
http://dx.doi.org/10.3390/electronics11152413
_version_ 1783876388618502144