Does human movement-induced airflow elevate infection risk in burn patient's isolation ward? A validated dynamics numerical simulation approach

An isolation ward requires a highly controlled and contamination-free environment since the settling of bacteria-carrying particles (shed by medical staff) on patients’ wounds could cause infections. The present study examines the effect of medical staff's walking movement on airflow distributi...

Full description

Saved in:
Bibliographic Details
Main Authors: Tan, Huiyi, Wong, Keng Yinn, Othman, Mohd. Hafiz Dzarfan, Nyakuma, Bemgba Bevan, Vui Sheng, Desmond Daniel Chin, Kek, Hong Yee, Ho, Wai Shin, Hashim, Haslenda, Chiong, Meng Choung, Zubir, Muhammad Afiq, Abdul Wahab, Nur Haliza, Wong, Syie Luing, Abdul Wahab, Roswanira, Hatif, Ihab Hasan
Format: Article
Published: Elsevier Ltd 2023
Subjects:
Online Access:http://eprints.utm.my/106743/
http://dx.doi.org/10.1016/j.enbuild.2023.112810
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Universiti Teknologi Malaysia