Behaviour of corroded circular steel tube strengthened with external FRP tube grouting under eccentric loading: numerical study
This paper uses ABAQUS software to perform finite element simulation on eccentric compression member of corroded circular steel tubes strengthened by FRP tube grouting. The working mechanisms, failure mode and the lifting of mechanical properties are investigated. The results show that the load–disp...
Saved in:
Main Authors: | , , , , , |
---|---|
Format: | Article |
Published: |
Elsevier Ltd
2023
|
Subjects: | |
Online Access: | http://eprints.utm.my/107160/ http://dx.doi.org/10.1016/j.istruc.2023.06.141 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Institution: | Universiti Teknologi Malaysia |
id |
my.utm.107160 |
---|---|
record_format |
eprints |
spelling |
my.utm.1071602024-08-28T07:15:33Z http://eprints.utm.my/107160/ Behaviour of corroded circular steel tube strengthened with external FRP tube grouting under eccentric loading: numerical study Fu, Hao Zhao, Huanhuan Pan, Zhiyong Wu, Zhaoqi Chin, Chee Loong Ma, Chau Khun TA Engineering (General). Civil engineering (General) This paper uses ABAQUS software to perform finite element simulation on eccentric compression member of corroded circular steel tubes strengthened by FRP tube grouting. The working mechanisms, failure mode and the lifting of mechanical properties are investigated. The results show that the load–displacement curve of the member represents both bilinear and trilinear models. The former is in the overall buckling failure mode, while the latter is in the strength failure mode of the circular steel tube with bare ends. After strengthening, the bearing capacity increases by up to 114.99%. Moreover, the increase positively correlates with corrosion rate, grouting thickness, and FRP tube thickness. It first decreases before increasing as the slenderness ratio changes, while the concrete strength has little effect. At the same time, the bound flexural stiffness ratio is derived and provides reference suggestions for the practical engineering application of FRP tube grouting to strengthen corroded steel structures. Elsevier Ltd 2023-10 Article PeerReviewed Fu, Hao and Zhao, Huanhuan and Pan, Zhiyong and Wu, Zhaoqi and Chin, Chee Loong and Ma, Chau Khun (2023) Behaviour of corroded circular steel tube strengthened with external FRP tube grouting under eccentric loading: numerical study. Structures, 56 (NA). NA. ISSN 2352-0124 http://dx.doi.org/10.1016/j.istruc.2023.06.141 DOI:10.1016/j.istruc.2023.06.141 |
institution |
Universiti Teknologi Malaysia |
building |
UTM Library |
collection |
Institutional Repository |
continent |
Asia |
country |
Malaysia |
content_provider |
Universiti Teknologi Malaysia |
content_source |
UTM Institutional Repository |
url_provider |
http://eprints.utm.my/ |
topic |
TA Engineering (General). Civil engineering (General) |
spellingShingle |
TA Engineering (General). Civil engineering (General) Fu, Hao Zhao, Huanhuan Pan, Zhiyong Wu, Zhaoqi Chin, Chee Loong Ma, Chau Khun Behaviour of corroded circular steel tube strengthened with external FRP tube grouting under eccentric loading: numerical study |
description |
This paper uses ABAQUS software to perform finite element simulation on eccentric compression member of corroded circular steel tubes strengthened by FRP tube grouting. The working mechanisms, failure mode and the lifting of mechanical properties are investigated. The results show that the load–displacement curve of the member represents both bilinear and trilinear models. The former is in the overall buckling failure mode, while the latter is in the strength failure mode of the circular steel tube with bare ends. After strengthening, the bearing capacity increases by up to 114.99%. Moreover, the increase positively correlates with corrosion rate, grouting thickness, and FRP tube thickness. It first decreases before increasing as the slenderness ratio changes, while the concrete strength has little effect. At the same time, the bound flexural stiffness ratio is derived and provides reference suggestions for the practical engineering application of FRP tube grouting to strengthen corroded steel structures. |
format |
Article |
author |
Fu, Hao Zhao, Huanhuan Pan, Zhiyong Wu, Zhaoqi Chin, Chee Loong Ma, Chau Khun |
author_facet |
Fu, Hao Zhao, Huanhuan Pan, Zhiyong Wu, Zhaoqi Chin, Chee Loong Ma, Chau Khun |
author_sort |
Fu, Hao |
title |
Behaviour of corroded circular steel tube strengthened with external FRP tube grouting under eccentric loading: numerical study |
title_short |
Behaviour of corroded circular steel tube strengthened with external FRP tube grouting under eccentric loading: numerical study |
title_full |
Behaviour of corroded circular steel tube strengthened with external FRP tube grouting under eccentric loading: numerical study |
title_fullStr |
Behaviour of corroded circular steel tube strengthened with external FRP tube grouting under eccentric loading: numerical study |
title_full_unstemmed |
Behaviour of corroded circular steel tube strengthened with external FRP tube grouting under eccentric loading: numerical study |
title_sort |
behaviour of corroded circular steel tube strengthened with external frp tube grouting under eccentric loading: numerical study |
publisher |
Elsevier Ltd |
publishDate |
2023 |
url |
http://eprints.utm.my/107160/ http://dx.doi.org/10.1016/j.istruc.2023.06.141 |
_version_ |
1809136634685292544 |