An assessment of drinking water quality in parts of Skudai, Johor Bahru
In a assessment of drinking water quality in Skudai Johor Bahru, piped water samples in the distribution system from three different standpipe locations in Taman Sri Skudai, Taman Sri Pulai and Universiti Teknologi Malaysia (UTM) campus were collected and tested for selected ions and bacteriological...
Saved in:
Main Authors: | , , , , |
---|---|
Format: | Article |
Language: | English |
Published: |
Penerbit UTM Press
1992
|
Subjects: | |
Online Access: | http://eprints.utm.my/id/eprint/1245/1/AbdRasidOthman1992_AnAssessmentOfDrinkingWater.pdf http://eprints.utm.my/id/eprint/1245/ http://dx.doi.org/10.11113/jt.v20.1061 |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Institution: | Universiti Teknologi Malaysia |
Language: | English |
id |
my.utm.1245 |
---|---|
record_format |
eprints |
spelling |
my.utm.12452017-11-01T04:17:55Z http://eprints.utm.my/id/eprint/1245/ An assessment of drinking water quality in parts of Skudai, Johor Bahru Othman, Abd. Rasid Mohd. Nor, Mohd. Asri Aris, Azmi Teng, Keat Hui Jora Singh, Jagjit Singh TD Environmental technology. Sanitary engineering In a assessment of drinking water quality in Skudai Johor Bahru, piped water samples in the distribution system from three different standpipe locations in Taman Sri Skudai, Taman Sri Pulai and Universiti Teknologi Malaysia (UTM) campus were collected and tested for selected ions and bacteriological quality. The result show that pipe water supplied from a treatment plant at Gunung Pulai in Pontian was low in mineral content. No Eschericia Coli were detected expected at the UTM Campus with concentration of 3 counts/100 mL in one out of 12 sample tested. Total coliforms were found at each site with concentration ranging from 1 to 13 counts/100 mL in 15 out of 6 samples. Except for the coliforms and the fluoride levels exceeding a little over 1.5 mg/L in 8% of the samples, drinking water in the distribution system in the study area can generally be said to have met the World Health Organization (WHO) guidelines during the study period. However, with the detection of coliforms and E. Coli at the household standpipes, the possibility of the distribution system in Skudai having pathogen contamination from time to time cannot be dismissed. Penerbit UTM Press 1992-12 Article PeerReviewed application/pdf en http://eprints.utm.my/id/eprint/1245/1/AbdRasidOthman1992_AnAssessmentOfDrinkingWater.pdf Othman, Abd. Rasid and Mohd. Nor, Mohd. Asri and Aris, Azmi and Teng, Keat Hui and Jora Singh, Jagjit Singh (1992) An assessment of drinking water quality in parts of Skudai, Johor Bahru. Jurnal Teknologi, 20 . pp. 1-9. ISSN 2180-3722 http://dx.doi.org/10.11113/jt.v20.1061 doi:10.11113/jt.v20.1061 |
institution |
Universiti Teknologi Malaysia |
building |
UTM Library |
collection |
Institutional Repository |
continent |
Asia |
country |
Malaysia |
content_provider |
Universiti Teknologi Malaysia |
content_source |
UTM Institutional Repository |
url_provider |
http://eprints.utm.my/ |
language |
English |
topic |
TD Environmental technology. Sanitary engineering |
spellingShingle |
TD Environmental technology. Sanitary engineering Othman, Abd. Rasid Mohd. Nor, Mohd. Asri Aris, Azmi Teng, Keat Hui Jora Singh, Jagjit Singh An assessment of drinking water quality in parts of Skudai, Johor Bahru |
description |
In a assessment of drinking water quality in Skudai Johor Bahru, piped water samples in the distribution system from three different standpipe locations in Taman Sri Skudai, Taman Sri Pulai and Universiti Teknologi Malaysia (UTM) campus were collected and tested for selected ions and bacteriological quality. The result show that pipe water supplied from a treatment plant at Gunung Pulai in Pontian was low in mineral content. No Eschericia Coli were detected expected at the UTM Campus with concentration of 3 counts/100 mL in one out of 12 sample tested. Total coliforms were found at each site with concentration ranging from 1 to 13 counts/100 mL in 15 out of 6 samples. Except for the coliforms and the fluoride levels exceeding a little over 1.5 mg/L in 8% of the samples, drinking water in the distribution system in the study area can generally be said to have met the World Health Organization (WHO) guidelines during the study period. However, with the detection of coliforms and E. Coli at the household standpipes, the possibility of the distribution system in Skudai having pathogen contamination from time to time cannot be dismissed. |
format |
Article |
author |
Othman, Abd. Rasid Mohd. Nor, Mohd. Asri Aris, Azmi Teng, Keat Hui Jora Singh, Jagjit Singh |
author_facet |
Othman, Abd. Rasid Mohd. Nor, Mohd. Asri Aris, Azmi Teng, Keat Hui Jora Singh, Jagjit Singh |
author_sort |
Othman, Abd. Rasid |
title |
An assessment of drinking water quality in parts of Skudai, Johor Bahru |
title_short |
An assessment of drinking water quality in parts of Skudai, Johor Bahru |
title_full |
An assessment of drinking water quality in parts of Skudai, Johor Bahru |
title_fullStr |
An assessment of drinking water quality in parts of Skudai, Johor Bahru |
title_full_unstemmed |
An assessment of drinking water quality in parts of Skudai, Johor Bahru |
title_sort |
assessment of drinking water quality in parts of skudai, johor bahru |
publisher |
Penerbit UTM Press |
publishDate |
1992 |
url |
http://eprints.utm.my/id/eprint/1245/1/AbdRasidOthman1992_AnAssessmentOfDrinkingWater.pdf http://eprints.utm.my/id/eprint/1245/ http://dx.doi.org/10.11113/jt.v20.1061 |
_version_ |
1643643283889455104 |