The impact of solar chimney geometry for stack ventilation in Malaysia's single storey terraced house

In terms of passive cooling design in housing, tropical climates present the most difficult problem to solve. The climatic conditions of the tropical regions are characterized by high air temperatures, high relative humidity and very low wind speeds. These make the environmental conditions uncomfort...

Full description

Saved in:
Bibliographic Details
Main Author: Nugroho, Agung Murti
Format: Conference or Workshop Item
Published: 2007
Subjects:
Online Access:http://eprints.utm.my/id/eprint/1632/
Tags: Add Tag
No Tags, Be the first to tag this record!
Institution: Universiti Teknologi Malaysia
id my.utm.1632
record_format eprints
spelling my.utm.16322017-09-06T04:49:49Z http://eprints.utm.my/id/eprint/1632/ The impact of solar chimney geometry for stack ventilation in Malaysia's single storey terraced house Nugroho, Agung Murti G Geography (General) In terms of passive cooling design in housing, tropical climates present the most difficult problem to solve. The climatic conditions of the tropical regions are characterized by high air temperatures, high relative humidity and very low wind speeds. These make the environmental conditions uncomfortable. This situation arises from the low air velocity and high temperature experienced during day time. The wind effect is also not well utilized especially in the usual single sided ventilation. The field measurement study on an existing house indicated that the basic design of single storey terraced house is not effective in providing natural ventilation for achieving thermal comfort. It is hypothesized that solar–induced ventilation may be a viable alternative. Therefore this paper discusses the impact of solar chimney geometry for stack induced ventilation strategies on a single storey terraced house model under Malaysian conditions. The solar induced ventilation study involved computer simulation using Computational Fluid Dynamics where air movement and solar radiation simulation are the major variables. Validation of CFD FloVent was done by comparing the results with field measurements and it showed a good agreement. Further development of the solar induced ventilation designs have been made and evaluated to attain solar chimney geometry. The simulations were performed on a selected day of one year. The result showed that the solar chimney geometry of 3 x 1 m area and 3.5 m vertical height provided continuous air movement where highest velocity could reach 0.6 m/s (on 21st March, on north-south orientation). 2007 Conference or Workshop Item PeerReviewed Nugroho, Agung Murti (2007) The impact of solar chimney geometry for stack ventilation in Malaysia's single storey terraced house. In: Post-Graduate Seminar Semester 2 Session 2006/2007, 6 March 2007, Rumah Alumni, Universiti Teknologi Malaysia.
institution Universiti Teknologi Malaysia
building UTM Library
collection Institutional Repository
continent Asia
country Malaysia
content_provider Universiti Teknologi Malaysia
content_source UTM Institutional Repository
url_provider http://eprints.utm.my/
topic G Geography (General)
spellingShingle G Geography (General)
Nugroho, Agung Murti
The impact of solar chimney geometry for stack ventilation in Malaysia's single storey terraced house
description In terms of passive cooling design in housing, tropical climates present the most difficult problem to solve. The climatic conditions of the tropical regions are characterized by high air temperatures, high relative humidity and very low wind speeds. These make the environmental conditions uncomfortable. This situation arises from the low air velocity and high temperature experienced during day time. The wind effect is also not well utilized especially in the usual single sided ventilation. The field measurement study on an existing house indicated that the basic design of single storey terraced house is not effective in providing natural ventilation for achieving thermal comfort. It is hypothesized that solar–induced ventilation may be a viable alternative. Therefore this paper discusses the impact of solar chimney geometry for stack induced ventilation strategies on a single storey terraced house model under Malaysian conditions. The solar induced ventilation study involved computer simulation using Computational Fluid Dynamics where air movement and solar radiation simulation are the major variables. Validation of CFD FloVent was done by comparing the results with field measurements and it showed a good agreement. Further development of the solar induced ventilation designs have been made and evaluated to attain solar chimney geometry. The simulations were performed on a selected day of one year. The result showed that the solar chimney geometry of 3 x 1 m area and 3.5 m vertical height provided continuous air movement where highest velocity could reach 0.6 m/s (on 21st March, on north-south orientation).
format Conference or Workshop Item
author Nugroho, Agung Murti
author_facet Nugroho, Agung Murti
author_sort Nugroho, Agung Murti
title The impact of solar chimney geometry for stack ventilation in Malaysia's single storey terraced house
title_short The impact of solar chimney geometry for stack ventilation in Malaysia's single storey terraced house
title_full The impact of solar chimney geometry for stack ventilation in Malaysia's single storey terraced house
title_fullStr The impact of solar chimney geometry for stack ventilation in Malaysia's single storey terraced house
title_full_unstemmed The impact of solar chimney geometry for stack ventilation in Malaysia's single storey terraced house
title_sort impact of solar chimney geometry for stack ventilation in malaysia's single storey terraced house
publishDate 2007
url http://eprints.utm.my/id/eprint/1632/
_version_ 1643643377513660416